Incidence and Risk Factors for Permanent Pacemaker Implantation After Tricuspid Valve Repair

Jae Woong Choi MD, PhD , Muath Bishawi MD, PhD , Carmelo Milano MD , Jeffrey Gaca MD , Keith Carr BS , Andrew Wang MD , Donald D. Glower MD
{"title":"Incidence and Risk Factors for Permanent Pacemaker Implantation After Tricuspid Valve Repair","authors":"Jae Woong Choi MD, PhD ,&nbsp;Muath Bishawi MD, PhD ,&nbsp;Carmelo Milano MD ,&nbsp;Jeffrey Gaca MD ,&nbsp;Keith Carr BS ,&nbsp;Andrew Wang MD ,&nbsp;Donald D. Glower MD","doi":"10.1016/j.atssr.2024.08.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Although the likelihood of needing a permanent pacemaker (PPM) after tricuspid valve (TV) repair has been thought to be low compared with TV replacement, the incidence and determinants are controversial. This study aimed to evaluate the incidence and risk factors for PPM implantation after TV repair.</div></div><div><h3>Methods</h3><div>A total of 1237 consecutive patients undergoing TV repair from 1997 to 2019 were reviewed using a prospectively maintained database, and 1058 patients were enrolled.</div></div><div><h3>Results</h3><div>Incidence of PPM implantation was 10.3% (n = 109). Median time to PPM implantation was 7 (range, 6-9) days. Indications for PPM implantation were heart block (n = 62, 56.9%), junctional or sinus bradycardia (n = 21, 19.3%), and ventricular arrhythmia (n = 17, 15.6%). Likelihood of PPM varied with concurrent procedures: left ventricular assist device (3.4%), mitral repair (11.2%), mitral valve replacement (13.7%), aortic and mitral valve replacement (19.2%), and isolated tricuspid repair (6.5%). Older age (odds ratio [OR], 1.020; 95% CI, 1.003-1.036), prior mediastinal radiation (OR, 4.106; 95% CI, 1.598-10.554), and concomitant mitral and aortic valve replacement (OR, 1.963; 95% CI, 1.046-3.683) were risk factors, and concomitant left ventricular assist device implantation (OR, 0.325; 95% CI, 0.139-0.759) was a protective factor for PPM implantation. PPM implantation did not affect the early outcomes, overall survival (<em>P</em> =.287), or cumulative incidence of recurrent moderate or greater tricuspid regurgitation (<em>P</em> =.890) or TV reoperation (<em>P</em> =.602).</div></div><div><h3>Conclusions</h3><div>The likelihood of PPM implantation after TV repair is relatively high, but PPM implantation does not affect the early and long-term clinical outcomes. Older age, prior mediastinal radiation, and concomitant mitral and aortic valve replacement are risk factors, and concomitant left ventricular assist device implantation is a protective factor for PPM implantation after TV repair.</div></div>","PeriodicalId":72234,"journal":{"name":"Annals of thoracic surgery short reports","volume":"3 1","pages":"Pages 37-41"},"PeriodicalIF":0.0000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of thoracic surgery short reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772993124003516","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Although the likelihood of needing a permanent pacemaker (PPM) after tricuspid valve (TV) repair has been thought to be low compared with TV replacement, the incidence and determinants are controversial. This study aimed to evaluate the incidence and risk factors for PPM implantation after TV repair.

Methods

A total of 1237 consecutive patients undergoing TV repair from 1997 to 2019 were reviewed using a prospectively maintained database, and 1058 patients were enrolled.

Results

Incidence of PPM implantation was 10.3% (n = 109). Median time to PPM implantation was 7 (range, 6-9) days. Indications for PPM implantation were heart block (n = 62, 56.9%), junctional or sinus bradycardia (n = 21, 19.3%), and ventricular arrhythmia (n = 17, 15.6%). Likelihood of PPM varied with concurrent procedures: left ventricular assist device (3.4%), mitral repair (11.2%), mitral valve replacement (13.7%), aortic and mitral valve replacement (19.2%), and isolated tricuspid repair (6.5%). Older age (odds ratio [OR], 1.020; 95% CI, 1.003-1.036), prior mediastinal radiation (OR, 4.106; 95% CI, 1.598-10.554), and concomitant mitral and aortic valve replacement (OR, 1.963; 95% CI, 1.046-3.683) were risk factors, and concomitant left ventricular assist device implantation (OR, 0.325; 95% CI, 0.139-0.759) was a protective factor for PPM implantation. PPM implantation did not affect the early outcomes, overall survival (P =.287), or cumulative incidence of recurrent moderate or greater tricuspid regurgitation (P =.890) or TV reoperation (P =.602).

Conclusions

The likelihood of PPM implantation after TV repair is relatively high, but PPM implantation does not affect the early and long-term clinical outcomes. Older age, prior mediastinal radiation, and concomitant mitral and aortic valve replacement are risk factors, and concomitant left ventricular assist device implantation is a protective factor for PPM implantation after TV repair.
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
53 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信