Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Arkadiusz Szarmach, Dominika Sabiniewicz-Ziajka, Małgorzata Grzywińska, Paweł Gać, Maciej Piskunowicz, Magdalena Wszędybył-Winklewska
{"title":"Computed Tomography Doses Calculation: Do We Really Need a New Dose Assessment Tool?","authors":"Arkadiusz Szarmach, Dominika Sabiniewicz-Ziajka, Małgorzata Grzywińska, Paweł Gać, Maciej Piskunowicz, Magdalena Wszędybył-Winklewska","doi":"10.3390/jcm14041348","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background/Objectives:</b> The increasing use of computed tomography (CT) scans significantly contributes to population exposure to ionizing radiation. Traditional dose metrics, such as dose-length product (DLP) and effective dose (ED), lack precision in reflecting individual radiation exposure. This study introduces a novel parameters such as size-specific effective dose (EDss) and the size-specific dose-length product (DLPss), to improve patient-specific dose estimation. The aim of this study is to enhance dose calculation accuracy, optimize CT protocols, and guide the development of next-generation CT technologies. <b>Methods:</b> A retrospective analysis of 247 abdominal and pelvic CT scans (113 women, 134 men) was conducted. Anthropometric parameters, including body mass index (BMI), cross-sectional dimensions, and dose indices, were measured. EDss and DLPss were calculated using size-specific correction factors, and statistical correlations between these parameters were assessed. <b>Results:</b> The mean BMI was 25.92 ± 5.34. DLPss values ranged from 261.63 to 1217.70 mGy·cm (mean: 627.83 ± 145.32) and were roughly 21% higher than traditional DLP values, with men showing slightly higher mean values than women. EDss values ranged from 6.65 to 15.45 mSv (mean: 9.42 ± 2.18 mSv), approximately 22% higher than traditional ED values, demonstrating improved individualization. Significant correlations were observed between BMI and effective diameter (r = 0.78), with stronger correlations in men (r = 0.85). The mean CTDIvol was 11.37 ± 3.50 mGy, and SSDE averaged 13.91 ± 2.39 mGy. Scan length reductions were observed in 53.8% of cases, with statistically significant differences by gender. <b>Conclusions:</b> EDss and DLPss offer improved accuracy in radiation dose estimation, addressing the limitations of traditional methods. Their adoption into clinical protocols, supported by AI-driven automation, could optimize diagnostic safety and significantly reduce radiation risk for patients. Further multicenter studies and technological advancements are recommended to validate these metrics and facilitate their integration into daily practice.</p>","PeriodicalId":15533,"journal":{"name":"Journal of Clinical Medicine","volume":"14 4","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/jcm14041348","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background/Objectives: The increasing use of computed tomography (CT) scans significantly contributes to population exposure to ionizing radiation. Traditional dose metrics, such as dose-length product (DLP) and effective dose (ED), lack precision in reflecting individual radiation exposure. This study introduces a novel parameters such as size-specific effective dose (EDss) and the size-specific dose-length product (DLPss), to improve patient-specific dose estimation. The aim of this study is to enhance dose calculation accuracy, optimize CT protocols, and guide the development of next-generation CT technologies. Methods: A retrospective analysis of 247 abdominal and pelvic CT scans (113 women, 134 men) was conducted. Anthropometric parameters, including body mass index (BMI), cross-sectional dimensions, and dose indices, were measured. EDss and DLPss were calculated using size-specific correction factors, and statistical correlations between these parameters were assessed. Results: The mean BMI was 25.92 ± 5.34. DLPss values ranged from 261.63 to 1217.70 mGy·cm (mean: 627.83 ± 145.32) and were roughly 21% higher than traditional DLP values, with men showing slightly higher mean values than women. EDss values ranged from 6.65 to 15.45 mSv (mean: 9.42 ± 2.18 mSv), approximately 22% higher than traditional ED values, demonstrating improved individualization. Significant correlations were observed between BMI and effective diameter (r = 0.78), with stronger correlations in men (r = 0.85). The mean CTDIvol was 11.37 ± 3.50 mGy, and SSDE averaged 13.91 ± 2.39 mGy. Scan length reductions were observed in 53.8% of cases, with statistically significant differences by gender. Conclusions: EDss and DLPss offer improved accuracy in radiation dose estimation, addressing the limitations of traditional methods. Their adoption into clinical protocols, supported by AI-driven automation, could optimize diagnostic safety and significantly reduce radiation risk for patients. Further multicenter studies and technological advancements are recommended to validate these metrics and facilitate their integration into daily practice.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Medicine
Journal of Clinical Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
5.70
自引率
7.70%
发文量
6468
审稿时长
16.32 days
期刊介绍: Journal of Clinical Medicine (ISSN 2077-0383), is an international scientific open access journal, providing a platform for advances in health care/clinical practices, the study of direct observation of patients and general medical research. This multi-disciplinary journal is aimed at a wide audience of medical researchers and healthcare professionals. Unique features of this journal: manuscripts regarding original research and ideas will be particularly welcomed.JCM also accepts reviews, communications, and short notes. There is no limit to publication length: our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信