Numerical Simulation of the Effect of Electrical Stimulation on Disuse After Hip Replacement.

IF 3.9 3区 工程技术 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Qian Wang, Chuanyong Qu, Xiaohui Li, Yufan Yan
{"title":"Numerical Simulation of the Effect of Electrical Stimulation on Disuse After Hip Replacement.","authors":"Qian Wang, Chuanyong Qu, Xiaohui Li, Yufan Yan","doi":"10.3390/biomedicines13020471","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Total hip replacement replaces the femoral head, which cannot heal, with an artificial femoral shaft to ensure the patient's normal life. However, due to the stress-masking effect of the proximal femur loaded with the artificial femur stem, the implant bears a large part of the load, resulting in insufficient stress stimulation of the proximal femur and bone waste remodeling. In turn, it is easy to lose bone, resulting in loosening. As a new treatment method, electrical stimulation has been widely used for bone loss, nonunion, and other diseases, and it has achieved good therapeutic effects. <b>Methods:</b> Therefore, in this work, electrical stimulation was introduced for postoperative density assessment, and a new disuse remodeling model was established to simulate density loss after remodeling and the resistance effect of electrical stimulation. The effects of various parameters on density loss in the model are discussed. <b>Results:</b> The simulation results revealed significant stress masking and density loss in the neck of the femur after hip replacement, and electrical stimulation placed in the neck of the femur may resist this density loss to a certain extent. The rate of bone mineral density reduction decreased after the addition of electrical stimulation, indicating that electrical stimulation can have a certain resistance to the density reduction caused by stress shielding, and this result is helpful for the rehabilitation of hip arthroplasty.</p>","PeriodicalId":8937,"journal":{"name":"Biomedicines","volume":"13 2","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2025-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11852602/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedicines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/biomedicines13020471","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Total hip replacement replaces the femoral head, which cannot heal, with an artificial femoral shaft to ensure the patient's normal life. However, due to the stress-masking effect of the proximal femur loaded with the artificial femur stem, the implant bears a large part of the load, resulting in insufficient stress stimulation of the proximal femur and bone waste remodeling. In turn, it is easy to lose bone, resulting in loosening. As a new treatment method, electrical stimulation has been widely used for bone loss, nonunion, and other diseases, and it has achieved good therapeutic effects. Methods: Therefore, in this work, electrical stimulation was introduced for postoperative density assessment, and a new disuse remodeling model was established to simulate density loss after remodeling and the resistance effect of electrical stimulation. The effects of various parameters on density loss in the model are discussed. Results: The simulation results revealed significant stress masking and density loss in the neck of the femur after hip replacement, and electrical stimulation placed in the neck of the femur may resist this density loss to a certain extent. The rate of bone mineral density reduction decreased after the addition of electrical stimulation, indicating that electrical stimulation can have a certain resistance to the density reduction caused by stress shielding, and this result is helpful for the rehabilitation of hip arthroplasty.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedicines
Biomedicines Biochemistry, Genetics and Molecular Biology-General Biochemistry,Genetics and Molecular Biology
CiteScore
5.20
自引率
8.50%
发文量
2823
审稿时长
8 weeks
期刊介绍: Biomedicines (ISSN 2227-9059; CODEN: BIOMID) is an international, scientific, open access journal on biomedicines published quarterly online by MDPI.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信