Advancing Breast Cancer Diagnosis: Optimization of Raman Spectroscopy for Urine-Based Early Detection.

IF 3.9 3区 工程技术 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
David Andras, Ramona G Cozan, Delia E Muresan, Vlad Moisoiu, George Crisan, Vasile Bintintan, George C Dindelegan, Nicolae Leopold, Stefania D Iancu
{"title":"Advancing Breast Cancer Diagnosis: Optimization of Raman Spectroscopy for Urine-Based Early Detection.","authors":"David Andras, Ramona G Cozan, Delia E Muresan, Vlad Moisoiu, George Crisan, Vasile Bintintan, George C Dindelegan, Nicolae Leopold, Stefania D Iancu","doi":"10.3390/biomedicines13020505","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>: Surface-enhanced Raman spectroscopy (SERS) analysis of urine is a promising liquid biopsy technique for cancer detection. However, its clinical translation is hindered by two major challenges that impact classification efficacy. First, the SERS signal of urine is confounded by fluctuations induced by physiological differences in urine composition such as pH and dilution. Second, the molecular origin of the SERS signal of urine is incompletely understood, limiting the interpretability of machine learning classifiers in terms of specific biochemical markers. <b>Methods</b>: In this pilot study, we analyzed urine samples from breast cancer patients (n = 18) and control subjects (n = 10) at three pH levels (5, 7, and 9). Additionally, we analyzed simulated urine mixtures consisting of uric acid, hypoxanthine, xanthine, and creatinine in physiological concentrations to explain the variation in the SERS spectra at different pH values. <b>Results</b>: Urine at pH 9 yielded the most detailed spectral features. The SERS spectral pattern under alkaline pH reflected greater contributions from hypoxanthine, uric acid, and creatinine, while xanthine contributions diminished due to competitive interactions at the SERS substrate surface. Normalizing SERS signals to the creatinine band at 1420 cm<sup>-1</sup> effectively mitigated the confounding effects of urine dilution. <b>Conclusions</b>: Optimizing the pH to 9 and normalizing to creatinine significantly enhances the interpretability and accuracy of SERS-based urine analysis for cancer detection. These findings offer important theoretical and practical advancements for the development of SERS-based liquid biopsy tools for cancer detection.</p>","PeriodicalId":8937,"journal":{"name":"Biomedicines","volume":"13 2","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11852463/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedicines","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3390/biomedicines13020505","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Surface-enhanced Raman spectroscopy (SERS) analysis of urine is a promising liquid biopsy technique for cancer detection. However, its clinical translation is hindered by two major challenges that impact classification efficacy. First, the SERS signal of urine is confounded by fluctuations induced by physiological differences in urine composition such as pH and dilution. Second, the molecular origin of the SERS signal of urine is incompletely understood, limiting the interpretability of machine learning classifiers in terms of specific biochemical markers. Methods: In this pilot study, we analyzed urine samples from breast cancer patients (n = 18) and control subjects (n = 10) at three pH levels (5, 7, and 9). Additionally, we analyzed simulated urine mixtures consisting of uric acid, hypoxanthine, xanthine, and creatinine in physiological concentrations to explain the variation in the SERS spectra at different pH values. Results: Urine at pH 9 yielded the most detailed spectral features. The SERS spectral pattern under alkaline pH reflected greater contributions from hypoxanthine, uric acid, and creatinine, while xanthine contributions diminished due to competitive interactions at the SERS substrate surface. Normalizing SERS signals to the creatinine band at 1420 cm-1 effectively mitigated the confounding effects of urine dilution. Conclusions: Optimizing the pH to 9 and normalizing to creatinine significantly enhances the interpretability and accuracy of SERS-based urine analysis for cancer detection. These findings offer important theoretical and practical advancements for the development of SERS-based liquid biopsy tools for cancer detection.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedicines
Biomedicines Biochemistry, Genetics and Molecular Biology-General Biochemistry,Genetics and Molecular Biology
CiteScore
5.20
自引率
8.50%
发文量
2823
审稿时长
8 weeks
期刊介绍: Biomedicines (ISSN 2227-9059; CODEN: BIOMID) is an international, scientific, open access journal on biomedicines published quarterly online by MDPI.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信