Imaging and Image Processing Techniques for High-Resolution Visualization of Connective Tissue with MRI: Application to Fascia, Aponeurosis, and Tendon.

IF 2.7 Q3 IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY
Meeghage Randika Perera, Graeme M Bydder, Samantha J Holdsworth, Geoffrey G Handsfield
{"title":"Imaging and Image Processing Techniques for High-Resolution Visualization of Connective Tissue with MRI: Application to Fascia, Aponeurosis, and Tendon.","authors":"Meeghage Randika Perera, Graeme M Bydder, Samantha J Holdsworth, Geoffrey G Handsfield","doi":"10.3390/jimaging11020043","DOIUrl":null,"url":null,"abstract":"<p><p>Recent interest in musculoskeletal connective tissues like tendons, aponeurosis, and deep fascia has led to a greater focus on in vivo medical imaging, particularly MRI. Given the rapid T<sub>2</sub>* decay of collagenous tissues, advanced ultra-short echo time (UTE) MRI sequences have proven useful in generating high-signal images of these tissues. To further these advances, we discuss the integration of UTE with Diffusion Tensor Imaging (DTI) and explore image processing techniques to enhance the localization, labeling, and modeling of connective tissues. These techniques are especially valuable for extracting features from thin tissues that may be difficult to distinguish. We present data from lower leg scans of 30 healthy subjects using a non-Cartesian MRI sequence to acquire axial 2D images to segment skeletal muscle and connective tissue. DTI helped differentiate aponeurosis from deep fascia by analyzing muscle fiber orientations. The dual echo imaging methods yielded high-resolution images of deep fascia, where in-plane spatial resolutions were between 0.3 × 0.3 mm to 0.5 × 0.5 mm with a slice thickness of 3-5 mm. Techniques such as K-Means clustering, FFT edge detection, and region-specific scaling were most effective in enhancing images of deep fascia, aponeurosis, and tendon to enable high-fidelity modeling of these tissues.</p>","PeriodicalId":37035,"journal":{"name":"Journal of Imaging","volume":"11 2","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856697/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jimaging11020043","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Recent interest in musculoskeletal connective tissues like tendons, aponeurosis, and deep fascia has led to a greater focus on in vivo medical imaging, particularly MRI. Given the rapid T2* decay of collagenous tissues, advanced ultra-short echo time (UTE) MRI sequences have proven useful in generating high-signal images of these tissues. To further these advances, we discuss the integration of UTE with Diffusion Tensor Imaging (DTI) and explore image processing techniques to enhance the localization, labeling, and modeling of connective tissues. These techniques are especially valuable for extracting features from thin tissues that may be difficult to distinguish. We present data from lower leg scans of 30 healthy subjects using a non-Cartesian MRI sequence to acquire axial 2D images to segment skeletal muscle and connective tissue. DTI helped differentiate aponeurosis from deep fascia by analyzing muscle fiber orientations. The dual echo imaging methods yielded high-resolution images of deep fascia, where in-plane spatial resolutions were between 0.3 × 0.3 mm to 0.5 × 0.5 mm with a slice thickness of 3-5 mm. Techniques such as K-Means clustering, FFT edge detection, and region-specific scaling were most effective in enhancing images of deep fascia, aponeurosis, and tendon to enable high-fidelity modeling of these tissues.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Imaging
Journal of Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.90
自引率
6.20%
发文量
303
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信