Accurate Prostate Segmentation in Large-Scale Magnetic Resonance Imaging Datasets via First-in-First-Out Feature Memory and Multi-Scale Context Modeling.

IF 2.7 Q3 IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY
Jingyi Zhu, Xukun Zhang, Xiao Luo, Zhiji Zheng, Kun Zhou, Yanlan Kang, Haiqing Li, Daoying Geng
{"title":"Accurate Prostate Segmentation in Large-Scale Magnetic Resonance Imaging Datasets via First-in-First-Out Feature Memory and Multi-Scale Context Modeling.","authors":"Jingyi Zhu, Xukun Zhang, Xiao Luo, Zhiji Zheng, Kun Zhou, Yanlan Kang, Haiqing Li, Daoying Geng","doi":"10.3390/jimaging11020061","DOIUrl":null,"url":null,"abstract":"<p><p>Prostate cancer, a prevalent malignancy affecting males globally, underscores the critical need for precise prostate segmentation in diagnostic imaging. However, accurate delineation via MRI still faces several challenges: (1) The distinction of the prostate from surrounding soft tissues is impeded by subtle boundaries in MRI images. (2) Regions such as the apex and base of the prostate exhibit inherent blurriness, which complicates edge extraction and precise segmentation. The objective of this study was to precisely delineate the borders of the prostate including the apex and base regions. This study introduces a multi-scale context modeling module to enhance boundary pixel representation, thus reducing the impact of irrelevant features on segmentation outcomes. Utilizing a first-in-first-out dynamic adjustment mechanism, the proposed methodology optimizes feature vector selection, thereby enhancing segmentation outcomes for challenging apex and base regions of the prostate. Segmentation of the prostate on 2175 clinically annotated MRI datasets demonstrated that our proposed MCM-UNet outperforms existing methods. The Average Symmetric Surface Distance (ASSD) and Dice similarity coefficient (DSC) for prostate segmentation were 0.58 voxels and 91.71%, respectively. The prostate segmentation results closely matched those manually delineated by experienced radiologists. Consequently, our method significantly enhances the accuracy of prostate segmentation and holds substantial significance in the diagnosis and treatment of prostate cancer.</p>","PeriodicalId":37035,"journal":{"name":"Journal of Imaging","volume":"11 2","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856738/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jimaging11020061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Prostate cancer, a prevalent malignancy affecting males globally, underscores the critical need for precise prostate segmentation in diagnostic imaging. However, accurate delineation via MRI still faces several challenges: (1) The distinction of the prostate from surrounding soft tissues is impeded by subtle boundaries in MRI images. (2) Regions such as the apex and base of the prostate exhibit inherent blurriness, which complicates edge extraction and precise segmentation. The objective of this study was to precisely delineate the borders of the prostate including the apex and base regions. This study introduces a multi-scale context modeling module to enhance boundary pixel representation, thus reducing the impact of irrelevant features on segmentation outcomes. Utilizing a first-in-first-out dynamic adjustment mechanism, the proposed methodology optimizes feature vector selection, thereby enhancing segmentation outcomes for challenging apex and base regions of the prostate. Segmentation of the prostate on 2175 clinically annotated MRI datasets demonstrated that our proposed MCM-UNet outperforms existing methods. The Average Symmetric Surface Distance (ASSD) and Dice similarity coefficient (DSC) for prostate segmentation were 0.58 voxels and 91.71%, respectively. The prostate segmentation results closely matched those manually delineated by experienced radiologists. Consequently, our method significantly enhances the accuracy of prostate segmentation and holds substantial significance in the diagnosis and treatment of prostate cancer.

通过先进先出特征记忆和多尺度上下文建模在大规模磁共振成像数据集中进行前列腺精确分段
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Imaging
Journal of Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.90
自引率
6.20%
发文量
303
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信