Dimensional Accuracy Assessment of Medical Anatomical Models Produced by Hospital-Based Fused Deposition Modeling 3D Printer.

IF 2.7 Q3 IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY
Kevin Wendo, Catherine Behets, Olivier Barbier, Benoit Herman, Thomas Schubert, Benoit Raucent, Raphael Olszewski
{"title":"Dimensional Accuracy Assessment of Medical Anatomical Models Produced by Hospital-Based Fused Deposition Modeling 3D Printer.","authors":"Kevin Wendo, Catherine Behets, Olivier Barbier, Benoit Herman, Thomas Schubert, Benoit Raucent, Raphael Olszewski","doi":"10.3390/jimaging11020039","DOIUrl":null,"url":null,"abstract":"<p><p>As 3D printing technology expands rapidly in medical disciplines, the accuracy evaluation of 3D-printed medical models is required. However, no established guidelines to assess the dimensional error of anatomical models exist. This study aims to evaluate the dimensional accuracy of medical models 3D-printed using a hospital-based Fused Deposition Modeling (FDM) 3D printer. Two dissected cadaveric right hands were marked with Titanium Kirshner wires to identify landmarks on the heads and bases of all metacarpals and proximal and middle phalanges. Both hands were scanned using a Cone Beam Computed Tomography scanner. Image post-processing and segmentation were performed on 3D Slicer software. Hand models were 3D-printed using a professional hospital-based FDM 3D printer. Manual measurements of all landmarks marked on both pairs of cadaveric and 3D-printed hands were taken by two independent observers using a digital caliper. The Mean Absolute Difference (MAD) and Mean Dimensional Error (MDE) were calculated. Our results showed an acceptable level of dimensional accuracy. The overall study's MAD was 0.32 mm (±0.34), and its MDE was 1.03% (±0.83). These values fall within the recommended range of errors. A high level of dimensional accuracy of the 3D-printed anatomical models was achieved, suggesting their reliability and suitability for medical applications.</p>","PeriodicalId":37035,"journal":{"name":"Journal of Imaging","volume":"11 2","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11856956/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/jimaging11020039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMAGING SCIENCE & PHOTOGRAPHIC TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

As 3D printing technology expands rapidly in medical disciplines, the accuracy evaluation of 3D-printed medical models is required. However, no established guidelines to assess the dimensional error of anatomical models exist. This study aims to evaluate the dimensional accuracy of medical models 3D-printed using a hospital-based Fused Deposition Modeling (FDM) 3D printer. Two dissected cadaveric right hands were marked with Titanium Kirshner wires to identify landmarks on the heads and bases of all metacarpals and proximal and middle phalanges. Both hands were scanned using a Cone Beam Computed Tomography scanner. Image post-processing and segmentation were performed on 3D Slicer software. Hand models were 3D-printed using a professional hospital-based FDM 3D printer. Manual measurements of all landmarks marked on both pairs of cadaveric and 3D-printed hands were taken by two independent observers using a digital caliper. The Mean Absolute Difference (MAD) and Mean Dimensional Error (MDE) were calculated. Our results showed an acceptable level of dimensional accuracy. The overall study's MAD was 0.32 mm (±0.34), and its MDE was 1.03% (±0.83). These values fall within the recommended range of errors. A high level of dimensional accuracy of the 3D-printed anatomical models was achieved, suggesting their reliability and suitability for medical applications.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Imaging
Journal of Imaging Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
5.90
自引率
6.20%
发文量
303
审稿时长
7 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信