Clinical safety and efficacy of stent-assisted coil embolization with ACCERO stent in cerebral aneurysm: Short-term follow-up and precaution for use.

Young Ha Kim, Chang Hyeun Kim, Sang Weon Lee, Chi Hyung Lee, Su Hun Lee, Jun Seok Lee, Soon Ki Sung, Dong Wuk Son
{"title":"Clinical safety and efficacy of stent-assisted coil embolization with ACCERO stent in cerebral aneurysm: Short-term follow-up and precaution for use.","authors":"Young Ha Kim, Chang Hyeun Kim, Sang Weon Lee, Chi Hyung Lee, Su Hun Lee, Jun Seok Lee, Soon Ki Sung, Dong Wuk Son","doi":"10.7461/jcen.2025.E2025.02.002","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Stent-assisted coil embolization (SAC) is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new ACCERO stent for the treatment of cerebral aneurysms.</p><p><strong>Methods: </strong>It was a retrospective, single-center study. Nine ruptured and 41 unruptured cerebral aneurysms were treated using the ACCERO stent between February 2021 and December 2023. Patient demographics, aneurysm characteristics, procedural parameters, grade of occlusion, complications, and clinical outcomes were analyzed. Follow-up was conducted with magnetic resonance angiography (MRA) or Digital subtraction angiography (DSA) was performed 6 to 12 months after the procedure.</p><p><strong>Results: </strong>The ACCERO stent deployment was attempted in 51 cases, with replacement by the Neuroform Atlas stent in 1 case. Successful stent deployment was achieved in 50 cases, and appropriate wall apposition to the parent artery. The average clinical follow-up period was 17.1 months. Intimal hyperplasia was observed in 1 case, but no other clinical complications related to the stent occurred. Favorable clinical outcomes were observed in 92% of patients (46/50), including those with subarachnoid hemorrhage. Immediate favorable angiographic outcomes and complete occlusion were achieved in 90% (45/50) and 74% (37/50) of cases, respectively. Among the 45 patients who had imaging follow-up, favorable angiographic outcomes and complete occlusion were observed in 93.3% (43/45) and 82.2% (37/45) of cases, respectively.</p><p><strong>Conclusions: </strong>The ACCERO stent is a braided-type stent that requires more attention than stents, such as the Neuroform Atlas or Enterprise stents. However, since the struts of the stent are fully visible, it can be more useful in treating challenging aneurysms once the user becomes familiar with its use.</p>","PeriodicalId":94072,"journal":{"name":"Journal of cerebrovascular and endovascular neurosurgery","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cerebrovascular and endovascular neurosurgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7461/jcen.2025.E2025.02.002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Stent-assisted coil embolization (SAC) is an effective method of treating intracranial aneurysms. The aim of the study was to assess the safety and efficacy of the new ACCERO stent for the treatment of cerebral aneurysms.

Methods: It was a retrospective, single-center study. Nine ruptured and 41 unruptured cerebral aneurysms were treated using the ACCERO stent between February 2021 and December 2023. Patient demographics, aneurysm characteristics, procedural parameters, grade of occlusion, complications, and clinical outcomes were analyzed. Follow-up was conducted with magnetic resonance angiography (MRA) or Digital subtraction angiography (DSA) was performed 6 to 12 months after the procedure.

Results: The ACCERO stent deployment was attempted in 51 cases, with replacement by the Neuroform Atlas stent in 1 case. Successful stent deployment was achieved in 50 cases, and appropriate wall apposition to the parent artery. The average clinical follow-up period was 17.1 months. Intimal hyperplasia was observed in 1 case, but no other clinical complications related to the stent occurred. Favorable clinical outcomes were observed in 92% of patients (46/50), including those with subarachnoid hemorrhage. Immediate favorable angiographic outcomes and complete occlusion were achieved in 90% (45/50) and 74% (37/50) of cases, respectively. Among the 45 patients who had imaging follow-up, favorable angiographic outcomes and complete occlusion were observed in 93.3% (43/45) and 82.2% (37/45) of cases, respectively.

Conclusions: The ACCERO stent is a braided-type stent that requires more attention than stents, such as the Neuroform Atlas or Enterprise stents. However, since the struts of the stent are fully visible, it can be more useful in treating challenging aneurysms once the user becomes familiar with its use.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信