Improved Biomechanical Performance of Tibial Spine Fracture Repair With Suture and Anchor Fixation in Pediatric Cadaveric Knees.

IF 2.4 3区 医学 Q2 ORTHOPEDICS
Orthopaedic Journal of Sports Medicine Pub Date : 2025-02-20 eCollection Date: 2025-02-01 DOI:10.1177/23259671241306194
Thomas M Johnstone, Ian Hollyer, Kelly McFarlane, Amin Alayeh, Marc Tompkins, Theodore Ganley, Yi-Meng Yen, Henry B Ellis, Calvin K Chan, Daniel W Green, Seth L Sherman, Kevin G Shea
{"title":"Improved Biomechanical Performance of Tibial Spine Fracture Repair With Suture and Anchor Fixation in Pediatric Cadaveric Knees.","authors":"Thomas M Johnstone, Ian Hollyer, Kelly McFarlane, Amin Alayeh, Marc Tompkins, Theodore Ganley, Yi-Meng Yen, Henry B Ellis, Calvin K Chan, Daniel W Green, Seth L Sherman, Kevin G Shea","doi":"10.1177/23259671241306194","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Prior studies in porcine and adult human bone suggest that suture fixation is superior to screw fixation of pediatric tibial spine fractures (TSFs). However, we have previously demonstrated that 2-suture repair was biomechanically comparable with 2-screw repair in human pediatric cadaveric knees.</p><p><strong>Purpose: </strong>To evaluate whether TSF fixation with sutures attached to anchors placed in stronger metadiaphyseal bone would produce biomechanically superior repair to 2-screw and 2-suture constructs.</p><p><strong>Study design: </strong>Controlled laboratory study.</p><p><strong>Methods: </strong>Six pediatric cadaveric knees were acquired. We applied the same TSF creation protocol used in our previous study, then repaired the fractures by passing 2 No. 2 FiberWire sutures through the fracture fragment and the base of the anterior cruciate ligament, with sutures passed through bony tunnels and secured to two 2.8-mm anchors in the metadiaphyseal cortex. This construct of suture plus suture anchor (suture anchor group) underwent the same biomechanical loading protocol used in our prior study, in which pediatric knees were randomly assigned to either screw fixation (n = 6; fractures reduced with two 4.0-mm cannulated screws and washers) or suture fixation (n = 6; fractures repaired as in the suture anchor group except the sutures were tied across a metaphyseal bony bridge after their exit from the bony tunnels). All specimens were mounted in flexion and biomechanically tested with cyclic loading followed by a load-to-failure test. New data were statistically compared with the prior study's results.</p><p><strong>Results: </strong>The suture anchor group had a median age of 9.00 years, while the screw and suture groups had identical median ages (8.50 years). All groups had an identical number of samples of each laterality. The ultimate failure load differed significantly across fixation methods (<i>P</i> = .006), primarily driven by higher ultimate failure loads in the suture anchor group (225.50 ± 46.46 N) when compared with the screw group (143.52 ± 41.97 N; <i>P</i> = .01) and suture group (135.35 ± 47.94 N; <i>P</i> = .009).</p><p><strong>Conclusion: </strong>TSF fixation with sutures tied to metadiaphyseal suture anchors provided significantly stronger repair than 2-suture and 2-screw constructs.</p><p><strong>Clinical relevance: </strong>The suture anchor fixation method for TSF may offer enhanced stability and durability to reduce the risk of postoperative complications while improving functional patient outcomes.</p>","PeriodicalId":19646,"journal":{"name":"Orthopaedic Journal of Sports Medicine","volume":"13 2","pages":"23259671241306194"},"PeriodicalIF":2.4000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11843678/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Journal of Sports Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23259671241306194","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Prior studies in porcine and adult human bone suggest that suture fixation is superior to screw fixation of pediatric tibial spine fractures (TSFs). However, we have previously demonstrated that 2-suture repair was biomechanically comparable with 2-screw repair in human pediatric cadaveric knees.

Purpose: To evaluate whether TSF fixation with sutures attached to anchors placed in stronger metadiaphyseal bone would produce biomechanically superior repair to 2-screw and 2-suture constructs.

Study design: Controlled laboratory study.

Methods: Six pediatric cadaveric knees were acquired. We applied the same TSF creation protocol used in our previous study, then repaired the fractures by passing 2 No. 2 FiberWire sutures through the fracture fragment and the base of the anterior cruciate ligament, with sutures passed through bony tunnels and secured to two 2.8-mm anchors in the metadiaphyseal cortex. This construct of suture plus suture anchor (suture anchor group) underwent the same biomechanical loading protocol used in our prior study, in which pediatric knees were randomly assigned to either screw fixation (n = 6; fractures reduced with two 4.0-mm cannulated screws and washers) or suture fixation (n = 6; fractures repaired as in the suture anchor group except the sutures were tied across a metaphyseal bony bridge after their exit from the bony tunnels). All specimens were mounted in flexion and biomechanically tested with cyclic loading followed by a load-to-failure test. New data were statistically compared with the prior study's results.

Results: The suture anchor group had a median age of 9.00 years, while the screw and suture groups had identical median ages (8.50 years). All groups had an identical number of samples of each laterality. The ultimate failure load differed significantly across fixation methods (P = .006), primarily driven by higher ultimate failure loads in the suture anchor group (225.50 ± 46.46 N) when compared with the screw group (143.52 ± 41.97 N; P = .01) and suture group (135.35 ± 47.94 N; P = .009).

Conclusion: TSF fixation with sutures tied to metadiaphyseal suture anchors provided significantly stronger repair than 2-suture and 2-screw constructs.

Clinical relevance: The suture anchor fixation method for TSF may offer enhanced stability and durability to reduce the risk of postoperative complications while improving functional patient outcomes.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Journal of Sports Medicine
Orthopaedic Journal of Sports Medicine Medicine-Orthopedics and Sports Medicine
CiteScore
4.30
自引率
7.70%
发文量
876
审稿时长
12 weeks
期刊介绍: The Orthopaedic Journal of Sports Medicine (OJSM), developed by the American Orthopaedic Society for Sports Medicine (AOSSM), is a global, peer-reviewed, open access journal that combines the interests of researchers and clinical practitioners across orthopaedic sports medicine, arthroscopy, and knee arthroplasty. Topics include original research in the areas of: -Orthopaedic Sports Medicine, including surgical and nonsurgical treatment of orthopaedic sports injuries -Arthroscopic Surgery (Shoulder/Elbow/Wrist/Hip/Knee/Ankle/Foot) -Relevant translational research -Sports traumatology/epidemiology -Knee and shoulder arthroplasty The OJSM also publishes relevant systematic reviews and meta-analyses. This journal is a member of the Committee on Publication Ethics (COPE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信