Detrended fluctuation analysis of day and night breathing parameters from a wearable respiratory holter

IF 7 2区 医学 Q1 BIOLOGY
Alessandra Angelucci, Andrea Aliverti
{"title":"Detrended fluctuation analysis of day and night breathing parameters from a wearable respiratory holter","authors":"Alessandra Angelucci,&nbsp;Andrea Aliverti","doi":"10.1016/j.compbiomed.2025.109907","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and objective</h3><div>This study focuses on the application of Detrended Fluctuation Analysis (DFA) to understand the variability and correlation properties of respiratory parameters time series obtained by means of a wearable.</div></div><div><h3>Methods</h3><div>Data from 18 healthy volunteers collected using the Airgo™ band, which provides signals proportional to thoracic circumference at a sampling frequency of 10 Hz. The primary aim was to provide preliminary normative data for DFA scaling factors.</div></div><div><h3>Results</h3><div>DFA was applied to 6-h recordings, revealing significant differences (p &lt; 0.001) in scaling factors (α values) for tidal volume (night: 0.97 [0.09], day: 0.88 [0.04]), minute ventilation (night: 1.02 [0.10], day: 0.91 [0.07), mean inspiratory flow (night: 0.98 [0.06], day: 0.88 [0.06]), mean expiratory flow (night: 0.89 [0.08], day: 0.81 [0.06]), and duty cycle (night: 0.64 [0.04], day: 0.59 [0.03]). Quadratic detrending highlighted additional differences not captured with linear detrending, particularly in inspiratory and expiratory time. These findings suggest distinct regulatory patterns during sleep.</div></div><div><h3>Conclusions</h3><div>DFA analysis of respiratory parameters obtained from wearable devices reveals distinct regulatory patterns between day and night conditions, particularly in parameters related to tidal volume and ventilation. These findings demonstrate the potential of DFA to uncover physiological differences in respiratory control mechanisms, especially during sleep, despite technical limitations such as the strong dependency of DFA scaling factors on sampling frequency, duration, and detrending order. Future research should address the limitations of sample size and expand normative datasets to include individuals with respiratory conditions, to translate this methodology into specific clinical applications.</div></div>","PeriodicalId":10578,"journal":{"name":"Computers in biology and medicine","volume":"188 ","pages":"Article 109907"},"PeriodicalIF":7.0000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in biology and medicine","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0010482525002586","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and objective

This study focuses on the application of Detrended Fluctuation Analysis (DFA) to understand the variability and correlation properties of respiratory parameters time series obtained by means of a wearable.

Methods

Data from 18 healthy volunteers collected using the Airgo™ band, which provides signals proportional to thoracic circumference at a sampling frequency of 10 Hz. The primary aim was to provide preliminary normative data for DFA scaling factors.

Results

DFA was applied to 6-h recordings, revealing significant differences (p < 0.001) in scaling factors (α values) for tidal volume (night: 0.97 [0.09], day: 0.88 [0.04]), minute ventilation (night: 1.02 [0.10], day: 0.91 [0.07), mean inspiratory flow (night: 0.98 [0.06], day: 0.88 [0.06]), mean expiratory flow (night: 0.89 [0.08], day: 0.81 [0.06]), and duty cycle (night: 0.64 [0.04], day: 0.59 [0.03]). Quadratic detrending highlighted additional differences not captured with linear detrending, particularly in inspiratory and expiratory time. These findings suggest distinct regulatory patterns during sleep.

Conclusions

DFA analysis of respiratory parameters obtained from wearable devices reveals distinct regulatory patterns between day and night conditions, particularly in parameters related to tidal volume and ventilation. These findings demonstrate the potential of DFA to uncover physiological differences in respiratory control mechanisms, especially during sleep, despite technical limitations such as the strong dependency of DFA scaling factors on sampling frequency, duration, and detrending order. Future research should address the limitations of sample size and expand normative datasets to include individuals with respiratory conditions, to translate this methodology into specific clinical applications.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Computers in biology and medicine
Computers in biology and medicine 工程技术-工程:生物医学
CiteScore
11.70
自引率
10.40%
发文量
1086
审稿时长
74 days
期刊介绍: Computers in Biology and Medicine is an international forum for sharing groundbreaking advancements in the use of computers in bioscience and medicine. This journal serves as a medium for communicating essential research, instruction, ideas, and information regarding the rapidly evolving field of computer applications in these domains. By encouraging the exchange of knowledge, we aim to facilitate progress and innovation in the utilization of computers in biology and medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信