FEMOSEAL CLOSE: multi-centre observational study with FemoSeal™ vascular closure device following peripheral percutaneous endovascular procedures.

IF 1.2 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Yann Gouëffic, Koen Deloose, Maxime Dubosq, Thomas Zeller
{"title":"FEMOSEAL CLOSE: multi-centre observational study with FemoSeal™ vascular closure device following peripheral percutaneous endovascular procedures.","authors":"Yann Gouëffic, Koen Deloose, Maxime Dubosq, Thomas Zeller","doi":"10.1186/s42155-025-00522-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of the FEMOSEAL CLOSE study was to assess the safety and effectiveness of FemoSeal™ vascular closure device in achieving haemostasis following transfemoral peripheral procedures in routine clinical practice.</p><p><strong>Materials and methods: </strong>This prospective, European, multi-centre, single-arm, post-market clinical follow-up study enrolled patients undergoing diagnostic or interventional peripheral endovascular procedures with FemoSeal™ vascular closure device in inpatient or outpatient settings. The primary endpoint was a composite of safety and effectiveness, with effectiveness defined as cessation of arterial bleeding without adjunctive treatment, and safety as freedom from major vascular complications in the first 6 h. Secondary endpoints included: minor access-site complications and major complications 6 h to 30 days post-procedure, and time to haemostasis, ambulation and discharge. Quality of life was assessed at baseline, discharge and 30-day follow-up. Device usability was also surveyed.</p><p><strong>Results: </strong>Between December 2021 and July 2022, 230 patients were enrolled in three European centres. The primary composite endpoint was achieved in 95.1% (215/226) [95% confidence interval: 91.46-97.55] of patients. The effectiveness component was achieved in 96.9% (219/226) [95% confidence interval: 93.70-98.70], and the safety component in 95.2% (220/230) [95% confidence interval: 92.15-97.90] of patients. FemoSeal™ vascular closure device deployment failure occurred in 1.6% (4/230) of cases, with subsequent manual compression achieving haemostasis. The median time to haemostasis was 0.42 min.</p><p><strong>Conclusions: </strong>The study device provides effective haemostasis and low rates of access-site complications up to 30 days post-procedure for patients undergoing peripheral endovascular interventions. It demonstrates good performance with rapid haemostasis.</p><p><strong>Trial registration: </strong>The study is registered at clinicaltrials.gov. (ClinicalTrials identifier: NCT05027698).</p>","PeriodicalId":52351,"journal":{"name":"CVIR Endovascular","volume":"8 1","pages":"15"},"PeriodicalIF":1.2000,"publicationDate":"2025-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11846783/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"CVIR Endovascular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42155-025-00522-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The purpose of the FEMOSEAL CLOSE study was to assess the safety and effectiveness of FemoSeal™ vascular closure device in achieving haemostasis following transfemoral peripheral procedures in routine clinical practice.

Materials and methods: This prospective, European, multi-centre, single-arm, post-market clinical follow-up study enrolled patients undergoing diagnostic or interventional peripheral endovascular procedures with FemoSeal™ vascular closure device in inpatient or outpatient settings. The primary endpoint was a composite of safety and effectiveness, with effectiveness defined as cessation of arterial bleeding without adjunctive treatment, and safety as freedom from major vascular complications in the first 6 h. Secondary endpoints included: minor access-site complications and major complications 6 h to 30 days post-procedure, and time to haemostasis, ambulation and discharge. Quality of life was assessed at baseline, discharge and 30-day follow-up. Device usability was also surveyed.

Results: Between December 2021 and July 2022, 230 patients were enrolled in three European centres. The primary composite endpoint was achieved in 95.1% (215/226) [95% confidence interval: 91.46-97.55] of patients. The effectiveness component was achieved in 96.9% (219/226) [95% confidence interval: 93.70-98.70], and the safety component in 95.2% (220/230) [95% confidence interval: 92.15-97.90] of patients. FemoSeal™ vascular closure device deployment failure occurred in 1.6% (4/230) of cases, with subsequent manual compression achieving haemostasis. The median time to haemostasis was 0.42 min.

Conclusions: The study device provides effective haemostasis and low rates of access-site complications up to 30 days post-procedure for patients undergoing peripheral endovascular interventions. It demonstrates good performance with rapid haemostasis.

Trial registration: The study is registered at clinicaltrials.gov. (ClinicalTrials identifier: NCT05027698).

求助全文
约1分钟内获得全文 求助全文
来源期刊
CVIR Endovascular
CVIR Endovascular Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
2.30
自引率
0.00%
发文量
59
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信