The Routine Collection of "Just-in-Case" Thyroid Aspirates for Molecular Testing at the Time of Initial Fine Needle Aspiration. Our Experience.

IF 0.7 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ultrasound Quarterly Pub Date : 2025-02-20 eCollection Date: 2025-03-01 DOI:10.1097/RUQ.0000000000000704
Adrian Dawkins, Dana Richards, Asmi Sabujan, Rashmi Nair
{"title":"The Routine Collection of \"Just-in-Case\" Thyroid Aspirates for Molecular Testing at the Time of Initial Fine Needle Aspiration. Our Experience.","authors":"Adrian Dawkins, Dana Richards, Asmi Sabujan, Rashmi Nair","doi":"10.1097/RUQ.0000000000000704","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Patients with Bethesda III/IV thyroid nodules may benefit from molecular testing in order to determine the likelihood of malignancy. The goal is to avoid unnecessary surgery for these often-benign nodules. The decision to acquire samples for molecular testing is typically made after formal cytologic interpretation. This creates anxiety and inconvenience for patients who must return for a repeat biopsy. We explored the impact of routinely collecting \"just-in-case\" samples from each thyroid nodule. Thus, a minimum of 4 samples were acquired from each nodule: 2 for routine cytologic analysis and 2 for possible genomic sequencing. Nodules subsequently determined to be Bethesda III/IV, were further evaluated by sending the prospectively acquired aspirates for genomic sequencing. Over a 7-month period, there were 69 consecutive patients with ages ranging from 24 to 88 years. There were 16 males and 63 females. Six patients had 2 nodules sampled, yielding total of 75 nodules. Of the 75 nodules, 4 (5.3%) were Bethesda I, 37 (49.3%) Bethesda II, 30 (40%) Bethesda III, 0 (0%) Bethesda IV, 1 (1.3%) Bethesda V, and 3 (4%) Bethesda VI. Of the 30 Bethesda III, 18 (60%) were deemed benign (4% risk of malignancy) by genomic testing. Nine (30%) were deemed 50% or 75% suspicious for malignancy. Two (6.7%) yielded insufficient material for analysis and 1 (3.3%) analysis was canceled because of nonpayment. There were no patient complications. Just-in-case samples prevented call-back of 40% of sampled nodules and thus deemed worthwhile and efficient despite adding an estimated 10 minutes to overall procedure time.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":"41 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000704","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract: Patients with Bethesda III/IV thyroid nodules may benefit from molecular testing in order to determine the likelihood of malignancy. The goal is to avoid unnecessary surgery for these often-benign nodules. The decision to acquire samples for molecular testing is typically made after formal cytologic interpretation. This creates anxiety and inconvenience for patients who must return for a repeat biopsy. We explored the impact of routinely collecting "just-in-case" samples from each thyroid nodule. Thus, a minimum of 4 samples were acquired from each nodule: 2 for routine cytologic analysis and 2 for possible genomic sequencing. Nodules subsequently determined to be Bethesda III/IV, were further evaluated by sending the prospectively acquired aspirates for genomic sequencing. Over a 7-month period, there were 69 consecutive patients with ages ranging from 24 to 88 years. There were 16 males and 63 females. Six patients had 2 nodules sampled, yielding total of 75 nodules. Of the 75 nodules, 4 (5.3%) were Bethesda I, 37 (49.3%) Bethesda II, 30 (40%) Bethesda III, 0 (0%) Bethesda IV, 1 (1.3%) Bethesda V, and 3 (4%) Bethesda VI. Of the 30 Bethesda III, 18 (60%) were deemed benign (4% risk of malignancy) by genomic testing. Nine (30%) were deemed 50% or 75% suspicious for malignancy. Two (6.7%) yielded insufficient material for analysis and 1 (3.3%) analysis was canceled because of nonpayment. There were no patient complications. Just-in-case samples prevented call-back of 40% of sampled nodules and thus deemed worthwhile and efficient despite adding an estimated 10 minutes to overall procedure time.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound Quarterly
Ultrasound Quarterly RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.50
自引率
7.70%
发文量
105
审稿时长
>12 weeks
期刊介绍: Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography. Official Journal of the Society of Radiologists in Ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信