Safety and Sustainability of Axillary Versus Radial Arterial Catheters in Critically Ill Children: A Retrospective Comparative Study.

IF 1.7 4区 医学 Q2 ANESTHESIOLOGY
Pediatric Anesthesia Pub Date : 2025-05-01 Epub Date: 2025-02-20 DOI:10.1111/pan.15087
Rotem Davidovich, Eytan Kaplan, Gili Kadmon, Elhanan Nahum, Avichai Weissbach
{"title":"Safety and Sustainability of Axillary Versus Radial Arterial Catheters in Critically Ill Children: A Retrospective Comparative Study.","authors":"Rotem Davidovich, Eytan Kaplan, Gili Kadmon, Elhanan Nahum, Avichai Weissbach","doi":"10.1111/pan.15087","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Arterial catheters are commonly used for hemodynamic monitoring and blood sampling in critically ill children, with the radial artery being the typical site. When radial cannulation is not feasible, alternative sites like the axillary artery may be utilized. However, the safety and sustainability of axillary arterial catheters compared to radial catheters in this population remain unclear.</p><p><strong>Aims: </strong>This study aims to assess the safety and sustainability of axillary arterial catheters compared to radial arterial catheters in pediatric intensive care unit patients.</p><p><strong>Methods: </strong>We conducted a retrospective, case-control study at a university-affiliated tertiary care pediatric intensive care unit. Patients aged 18 years or younger with axillary arterial catheters from January 2007 to December 2023 were compared to patients of similar ages with radial catheters.</p><p><strong>Results: </strong>A computerized chart review identified 306 patients with axillary catheters, compared to 306 randomly selected patients with radial catheters. The rate of catheter site replacement was identical in both groups (40 out of 306). The median duration of axillary catheter use was 34 h longer (95% CI: 24-48; p < 0.001). Only one patient in the axillary group (0.33%) experienced a vascular complication, recovering fully after intervention. Patients with axillary catheters were characterized by a higher Pediatric Index of Mortality 3 scores, Vasoactive-Inotropic Scores, and PICU mortality rates.</p><p><strong>Conclusions: </strong>In this critically ill pediatric cohort, axillary arterial catheters were used longer and in a more severely ill population than radial catheters. Despite these differences, both catheter types demonstrated comparable safety and sustainability profiles.</p>","PeriodicalId":19745,"journal":{"name":"Pediatric Anesthesia","volume":" ","pages":"389-393"},"PeriodicalIF":1.7000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/pan.15087","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Arterial catheters are commonly used for hemodynamic monitoring and blood sampling in critically ill children, with the radial artery being the typical site. When radial cannulation is not feasible, alternative sites like the axillary artery may be utilized. However, the safety and sustainability of axillary arterial catheters compared to radial catheters in this population remain unclear.

Aims: This study aims to assess the safety and sustainability of axillary arterial catheters compared to radial arterial catheters in pediatric intensive care unit patients.

Methods: We conducted a retrospective, case-control study at a university-affiliated tertiary care pediatric intensive care unit. Patients aged 18 years or younger with axillary arterial catheters from January 2007 to December 2023 were compared to patients of similar ages with radial catheters.

Results: A computerized chart review identified 306 patients with axillary catheters, compared to 306 randomly selected patients with radial catheters. The rate of catheter site replacement was identical in both groups (40 out of 306). The median duration of axillary catheter use was 34 h longer (95% CI: 24-48; p < 0.001). Only one patient in the axillary group (0.33%) experienced a vascular complication, recovering fully after intervention. Patients with axillary catheters were characterized by a higher Pediatric Index of Mortality 3 scores, Vasoactive-Inotropic Scores, and PICU mortality rates.

Conclusions: In this critically ill pediatric cohort, axillary arterial catheters were used longer and in a more severely ill population than radial catheters. Despite these differences, both catheter types demonstrated comparable safety and sustainability profiles.

危重儿童腋动脉导管与桡动脉导管的安全性和可持续性:回顾性比较研究。
背景:动脉导管常用于危重儿童的血流动力学监测和血液采样,其中桡动脉是典型的部位。当桡动脉插管不可行时,可以使用其他部位,如腋窝动脉。然而,与桡动脉导管相比,腋动脉导管在这一人群中的安全性和可持续性仍不清楚。目的:本研究旨在评估腋动脉导管与桡动脉导管在儿科重症监护病房患者中的安全性和可持续性。方法:我们在一所大学附属三级护理儿科重症监护室进行了一项回顾性病例对照研究。将2007年1月至2023年12月18岁及以下腋动脉导管患者与同龄桡动脉导管患者进行比较。结果:计算机图表回顾确定了306例腋窝导管患者,与306例随机选择的桡骨导管患者相比。两组的导管置换率相同(306例中有40例)。腋导管使用的中位时间延长了34小时(95% CI: 24-48;结论:在这个危重儿科队列中,腋窝动脉导管比桡动脉导管使用的时间更长,病情更严重。尽管存在这些差异,但两种导管类型显示出相当的安全性和可持续性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Anesthesia
Pediatric Anesthesia 医学-麻醉学
CiteScore
3.20
自引率
11.80%
发文量
222
审稿时长
3-8 weeks
期刊介绍: Devoted to the dissemination of research of interest and importance to practising anesthetists everywhere, the scientific and clinical content of Pediatric Anesthesia covers a wide selection of medical disciplines in all areas relevant to paediatric anaesthesia, pain management and peri-operative medicine. The International Editorial Board is supported by the Editorial Advisory Board and a team of Senior Advisors, to ensure that the journal is publishing the best work from the front line of research in the field. The journal publishes high-quality, relevant scientific and clinical research papers, reviews, commentaries, pro-con debates, historical vignettes, correspondence, case presentations and book reviews.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信