Surgical Outcomes of Olecranon Osteotomy Approach Combined With Submerged Kirschner Wires and Plate Fixation for Duckerley IIIB Distal Humeral Coronal Shear Fractures.

IF 1.8 2区 医学 Q2 ORTHOPEDICS
Orthopaedic Surgery Pub Date : 2025-04-01 Epub Date: 2025-02-19 DOI:10.1111/os.70005
Zhou-Feng Song, Wei-Qiang Zhao, Zeng-Li Zhang, Jie-Feng Huang
{"title":"Surgical Outcomes of Olecranon Osteotomy Approach Combined With Submerged Kirschner Wires and Plate Fixation for Duckerley IIIB Distal Humeral Coronal Shear Fractures.","authors":"Zhou-Feng Song, Wei-Qiang Zhao, Zeng-Li Zhang, Jie-Feng Huang","doi":"10.1111/os.70005","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Duckerley type IIIB distal humerus fractures are rare and complex injuries that pose significant challenges in both diagnosis and treatment. Currently, no consensus exists on the fixation method, with existing approaches often struggling to handle small fragments and associated with issues like elbow instability. The purpose of this study is to evaluate the surgical outcomes of submerged Kirschner wires combined with plate or submerged screw fixation technique for the treatment of Duckerley type IIIB distal humerus fractures.</p><p><strong>Methods: </strong>A retrospective analysis was conducted on 10 patients with Duckerley type IIIB distal humerus fractures who were treated at our hospital from February 2017 to April 2021. The treatment involved applying buried Kirschner wires combined with microplate or buried screw fixation technique through the olecranon osteotomy approach. The study included six males and four females, with a mean age of 51.4 ± 15.34 years (ranging from 22 to 69 years). During the follow-up, the elbow range of motion, Mayo Elbow Performance Score (MEPS), American Shoulder and Elbow Surgeons (ASES) score, and complications were assessed.</p><p><strong>Results: </strong>All 10 patients received regular clinical and imaging follow-up for a mean of 39.7 ± 8.8 months (range: 25-50 months). Postoperative incision healing was good for all patients, and no neurovascular injuries were noted. Two patients developed elbow pain. At the last follow-up before the internal fixation removal operation (9.6 ± 1.9 months), X-ray and CT findings confirmed bony healing, and no internal fixation loosening and breakage occurred in any of the patients, except for one case in which there was displacement of the Kirschner wires. The mean range of motion of the elbow before the internal fixation removal operation was extension 15.0° ± 21.6°, flexion 129.5° ± 28.1°, pronation 83.0° ± 9.2°, and supination 81.5° ± 8.0°. The MEPS score was 83.0 ± 8.3, and the ASES was 83.6 ± 7.8. At the last follow-up, the mean range of motion of the elbow was extension 10.0° ± 21.9°, flexion 133.5° ± 16.0°, pronation 88.0° ± 11.2°, and supination 85.0° ± 9.5°. The MEPS score was 84.6 ± 7.6, and the ASES was 84.1 ± 7.4.</p><p><strong>Conclusions: </strong>The treatment of Duckerley type IIIB low distal humerus fractures using submerged Kirschner wires combined with plate or submerged screw fixation technique has satisfactory advantages in terms of fracture reduction, maintenance of the position of internal fixation, and postoperative recovery.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":"1255-1264"},"PeriodicalIF":1.8000,"publicationDate":"2025-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.70005","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Duckerley type IIIB distal humerus fractures are rare and complex injuries that pose significant challenges in both diagnosis and treatment. Currently, no consensus exists on the fixation method, with existing approaches often struggling to handle small fragments and associated with issues like elbow instability. The purpose of this study is to evaluate the surgical outcomes of submerged Kirschner wires combined with plate or submerged screw fixation technique for the treatment of Duckerley type IIIB distal humerus fractures.

Methods: A retrospective analysis was conducted on 10 patients with Duckerley type IIIB distal humerus fractures who were treated at our hospital from February 2017 to April 2021. The treatment involved applying buried Kirschner wires combined with microplate or buried screw fixation technique through the olecranon osteotomy approach. The study included six males and four females, with a mean age of 51.4 ± 15.34 years (ranging from 22 to 69 years). During the follow-up, the elbow range of motion, Mayo Elbow Performance Score (MEPS), American Shoulder and Elbow Surgeons (ASES) score, and complications were assessed.

Results: All 10 patients received regular clinical and imaging follow-up for a mean of 39.7 ± 8.8 months (range: 25-50 months). Postoperative incision healing was good for all patients, and no neurovascular injuries were noted. Two patients developed elbow pain. At the last follow-up before the internal fixation removal operation (9.6 ± 1.9 months), X-ray and CT findings confirmed bony healing, and no internal fixation loosening and breakage occurred in any of the patients, except for one case in which there was displacement of the Kirschner wires. The mean range of motion of the elbow before the internal fixation removal operation was extension 15.0° ± 21.6°, flexion 129.5° ± 28.1°, pronation 83.0° ± 9.2°, and supination 81.5° ± 8.0°. The MEPS score was 83.0 ± 8.3, and the ASES was 83.6 ± 7.8. At the last follow-up, the mean range of motion of the elbow was extension 10.0° ± 21.9°, flexion 133.5° ± 16.0°, pronation 88.0° ± 11.2°, and supination 85.0° ± 9.5°. The MEPS score was 84.6 ± 7.6, and the ASES was 84.1 ± 7.4.

Conclusions: The treatment of Duckerley type IIIB low distal humerus fractures using submerged Kirschner wires combined with plate or submerged screw fixation technique has satisfactory advantages in terms of fracture reduction, maintenance of the position of internal fixation, and postoperative recovery.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Surgery
Orthopaedic Surgery ORTHOPEDICS-
CiteScore
3.40
自引率
14.30%
发文量
374
审稿时长
20 weeks
期刊介绍: Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery. The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信