Performance of Unmodified Mechanical Ventilators With 2% Hydrogen Gas Mixtures.

IF 2.4 4区 医学 Q2 CRITICAL CARE MEDICINE
Julia Garcia Mancebo, Kristen Sack, Richard Nguyen, Yifeng Peng, Syndy Sosa, Marc Anders, Dantin J Roddy, John N Kheir
{"title":"Performance of Unmodified Mechanical Ventilators With 2% Hydrogen Gas Mixtures.","authors":"Julia Garcia Mancebo, Kristen Sack, Richard Nguyen, Yifeng Peng, Syndy Sosa, Marc Anders, Dantin J Roddy, John N Kheir","doi":"10.4187/respcare.12371","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Molecular hydrogen (H<sub>2</sub>) is a breathable gas that has been shown to have anti-oxidative, anti-inflammatory, and anti-apoptotic properties that may positively impact ischemia-reperfusion injury. The provision of 2% H<sub>2</sub> through unmodified mechanical ventilators may facilitate the clinical translation of H<sub>2</sub> as a therapeutic in critical illness. The effect of 2% H<sub>2</sub> on ventilator performance is unknown. <b>Methods:</b> Unmodified Maquet Servo-i, Maquet Servo-u, Dräger Evita Infinity V500, and Dräger Evita Babylog VN500 ventilators from clinical stock were tested in an experimental closed system using certified, premixed air and O<sub>2</sub> containing 2% H<sub>2</sub> gas. Wall air and O<sub>2</sub> supply were used as control. Ventilator settings were varied across the spectrum of neonatal to adult settings. End points included (1) difference between set and delivered tidal volume (V<sub>T</sub>) (Douglas method), (2) difference between set versus delivered O<sub>2</sub> concentration, (3) delivered H<sub>2</sub> concentration (gas chromatography), and (4) ventilator pre-use check malfunction. Correlation between set and measured end points were quantified by linear regression analysis and bias by Bland-Altman analysis. <b>Results:</b> During H<sub>2</sub> administration, the average bias in measured versus set V<sub>T</sub> was within ± 10% for all ventilators except for the Babylog VN500, which exhibited an average bias of -89.2% (95% CI -107.0 to -71.3). The average bias in measured F<sub>IO<sub>2</sub></sub> was within ± 10% of set for all ventilators. Except for the Babylog VN500, all ventilators passed the pre-use check. <b>Conclusions:</b> Unmodified Servo-i, Servo-u, and Evita V500 ventilators deliver 2% H<sub>2</sub> mixtures with acceptable accuracy in V<sub>T</sub> and F<sub>IO<sub>2</sub></sub>. The Babylog VN500, which uses hot-wire anometry and a higher set operating temperature, exhibits unacceptably inaccurate delivery of V<sub>T</sub> with H<sub>2</sub> mixtures.</p>","PeriodicalId":21125,"journal":{"name":"Respiratory care","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2025-01-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4187/respcare.12371","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Molecular hydrogen (H2) is a breathable gas that has been shown to have anti-oxidative, anti-inflammatory, and anti-apoptotic properties that may positively impact ischemia-reperfusion injury. The provision of 2% H2 through unmodified mechanical ventilators may facilitate the clinical translation of H2 as a therapeutic in critical illness. The effect of 2% H2 on ventilator performance is unknown. Methods: Unmodified Maquet Servo-i, Maquet Servo-u, Dräger Evita Infinity V500, and Dräger Evita Babylog VN500 ventilators from clinical stock were tested in an experimental closed system using certified, premixed air and O2 containing 2% H2 gas. Wall air and O2 supply were used as control. Ventilator settings were varied across the spectrum of neonatal to adult settings. End points included (1) difference between set and delivered tidal volume (VT) (Douglas method), (2) difference between set versus delivered O2 concentration, (3) delivered H2 concentration (gas chromatography), and (4) ventilator pre-use check malfunction. Correlation between set and measured end points were quantified by linear regression analysis and bias by Bland-Altman analysis. Results: During H2 administration, the average bias in measured versus set VT was within ± 10% for all ventilators except for the Babylog VN500, which exhibited an average bias of -89.2% (95% CI -107.0 to -71.3). The average bias in measured FIO2 was within ± 10% of set for all ventilators. Except for the Babylog VN500, all ventilators passed the pre-use check. Conclusions: Unmodified Servo-i, Servo-u, and Evita V500 ventilators deliver 2% H2 mixtures with acceptable accuracy in VT and FIO2. The Babylog VN500, which uses hot-wire anometry and a higher set operating temperature, exhibits unacceptably inaccurate delivery of VT with H2 mixtures.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Respiratory care
Respiratory care 医学-呼吸系统
CiteScore
4.70
自引率
16.00%
发文量
209
审稿时长
1 months
期刊介绍: RESPIRATORY CARE is the official monthly science journal of the American Association for Respiratory Care. It is indexed in PubMed and included in ISI''s Web of Science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信