Efficacy of Noninvasive Ventilation With Expiratory Washout in Stable COPD Patients.

IF 2.4 4区 医学 Q2 CRITICAL CARE MEDICINE
Stacey Kung, Alex C Semprini, Louis W Kirton, Jess R Fogarin, Sascha K Zoellner, Richard Beasley, Allie Eathorne, Ruth A C Semprini
{"title":"Efficacy of Noninvasive Ventilation With Expiratory Washout in Stable COPD Patients.","authors":"Stacey Kung, Alex C Semprini, Louis W Kirton, Jess R Fogarin, Sascha K Zoellner, Richard Beasley, Allie Eathorne, Ruth A C Semprini","doi":"10.1089/respcare.11876","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> A noninvasive ventilation (NIV) mask has been designed to deliver NIV with expiratory washout to improve efficacy of ventilation by optimizing clearance of expired gases from the anatomic dead space. This study compared the performance and comfort of a novel investigational mask with expiratory washout with a conventional mask during NIV therapy. <b>Methods:</b> In this pilot crossover study, participants with severe stable COPD attended a single visit to receive bi-level NIV through 2 masks; the investigational mask with expiratory washout and a conventional mask. The order of mask use was randomly allocated, and each mask was used for 60 min with a 30-60-min washout in between. The primary outcome was transcutaneous carbon dioxide at 60 min. Other physiologic and NIV device variables were also assessed. <b>Results:</b> The mean difference (95% CI) in the transcutaneous carbon dioxide between the investigational and conventional masks at 60 min, adjusted for baseline, was -0.74 mm Hg, 95% CI -2.81 to 1.33 mm Hg (<i>P</i> = .45). The investigational mask with expiratory washout elicited a lower tidal volume (-128.7 mL, 95% CI -190.0 to -67.3 mL; <i>P</i> < .001) and minute ventilation (-2.28 L/min,<sup>,</sup> 95% CI -3.12 to -1.43 L/min; <i>P</i> < .001), and a higher leak (7.96 L/min, 95% CI 4.39-11.54 L/min; <i>P</i> < .001) than the conventional mask. There were no differences in other physiologic responses or ratings of dyspnea or comfort. <b>Conclusions:</b> NIV therapy delivered by using a novel mask with expiratory washout was similarly effective at reducing transcutaneous carbon dioxide, whereas the delivered tidal volume and minute ventilation were significantly lower when compared with a conventional mask in participants with severe COPD.</p>","PeriodicalId":21125,"journal":{"name":"Respiratory care","volume":"70 1","pages":"29-37"},"PeriodicalIF":2.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11824877/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/respcare.11876","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: A noninvasive ventilation (NIV) mask has been designed to deliver NIV with expiratory washout to improve efficacy of ventilation by optimizing clearance of expired gases from the anatomic dead space. This study compared the performance and comfort of a novel investigational mask with expiratory washout with a conventional mask during NIV therapy. Methods: In this pilot crossover study, participants with severe stable COPD attended a single visit to receive bi-level NIV through 2 masks; the investigational mask with expiratory washout and a conventional mask. The order of mask use was randomly allocated, and each mask was used for 60 min with a 30-60-min washout in between. The primary outcome was transcutaneous carbon dioxide at 60 min. Other physiologic and NIV device variables were also assessed. Results: The mean difference (95% CI) in the transcutaneous carbon dioxide between the investigational and conventional masks at 60 min, adjusted for baseline, was -0.74 mm Hg, 95% CI -2.81 to 1.33 mm Hg (P = .45). The investigational mask with expiratory washout elicited a lower tidal volume (-128.7 mL, 95% CI -190.0 to -67.3 mL; P < .001) and minute ventilation (-2.28 L/min,, 95% CI -3.12 to -1.43 L/min; P < .001), and a higher leak (7.96 L/min, 95% CI 4.39-11.54 L/min; P < .001) than the conventional mask. There were no differences in other physiologic responses or ratings of dyspnea or comfort. Conclusions: NIV therapy delivered by using a novel mask with expiratory washout was similarly effective at reducing transcutaneous carbon dioxide, whereas the delivered tidal volume and minute ventilation were significantly lower when compared with a conventional mask in participants with severe COPD.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Respiratory care
Respiratory care 医学-呼吸系统
CiteScore
4.70
自引率
16.00%
发文量
209
审稿时长
1 months
期刊介绍: RESPIRATORY CARE is the official monthly science journal of the American Association for Respiratory Care. It is indexed in PubMed and included in ISI''s Web of Science.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信