Zhimin Zhang, Xiaojie Chen, Xinyu Yao, Bin Li, Yafang Wang, Lin Zhang
{"title":"[Design and application of an adjustable facial support pad for prone position ventilation].","authors":"Zhimin Zhang, Xiaojie Chen, Xinyu Yao, Bin Li, Yafang Wang, Lin Zhang","doi":"10.3760/cma.j.cn121430-20240607-00492","DOIUrl":null,"url":null,"abstract":"<p><p>In recent years, prone mechanical ventilation has been widely used to improve oxygenation dysfunction in critically ill patients. During prone mechanical ventilation, the patient's face is compressed for a long time, and due to the difficulty in changing, facial pressure injuries and ocular complications are common and severe. These complications increase patient discomfort, reduce their tolerance and compliance with prone ventilation, and even cause tracheal tube displacement or dislodgement, leading to significant clinical challenges. In order to change this situation, the medical staff of the department of critical care medicine of the Second People's Hospital of Hengshui and the department of critical care medicine of Harrison International Peace Hospital had developed an adjustable facial support pad for prone ventilation, and obtained a National Utility Model Patent of China (ZL 2022 2 3295294.4). The device is composed of a facial support platform, a supporting telescopic foot frame and so on. There are front, back, left and right adjustable tracks below the support cushion platform, which can be adjusted to the best state suitable for the patient's face shape, which can alleviate the facial pressure injuries and ocular complications caused by the different sizes of each patient's face, improve the patient's comfort, and reduce the incidence of facial pressure injury and the occurrence of ocular complications of the patient. The height of the platform is adjusted by the telescopic feet, and there is a hook assembly below, which can be fixed by the clamp of the ventilator tubing, so as to prevent the ventilator tubing from pulling the endotracheal intubation due to the gravity of condensation, resulting in the displacement or even prolapse of the tracheal intubation, and reducing the occurrence of adverse events of tracheal intubation. It is worth promoting in the clinic.</p>","PeriodicalId":24079,"journal":{"name":"Zhonghua wei zhong bing ji jiu yi xue","volume":"37 1","pages":"70-72"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua wei zhong bing ji jiu yi xue","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3760/cma.j.cn121430-20240607-00492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
In recent years, prone mechanical ventilation has been widely used to improve oxygenation dysfunction in critically ill patients. During prone mechanical ventilation, the patient's face is compressed for a long time, and due to the difficulty in changing, facial pressure injuries and ocular complications are common and severe. These complications increase patient discomfort, reduce their tolerance and compliance with prone ventilation, and even cause tracheal tube displacement or dislodgement, leading to significant clinical challenges. In order to change this situation, the medical staff of the department of critical care medicine of the Second People's Hospital of Hengshui and the department of critical care medicine of Harrison International Peace Hospital had developed an adjustable facial support pad for prone ventilation, and obtained a National Utility Model Patent of China (ZL 2022 2 3295294.4). The device is composed of a facial support platform, a supporting telescopic foot frame and so on. There are front, back, left and right adjustable tracks below the support cushion platform, which can be adjusted to the best state suitable for the patient's face shape, which can alleviate the facial pressure injuries and ocular complications caused by the different sizes of each patient's face, improve the patient's comfort, and reduce the incidence of facial pressure injury and the occurrence of ocular complications of the patient. The height of the platform is adjusted by the telescopic feet, and there is a hook assembly below, which can be fixed by the clamp of the ventilator tubing, so as to prevent the ventilator tubing from pulling the endotracheal intubation due to the gravity of condensation, resulting in the displacement or even prolapse of the tracheal intubation, and reducing the occurrence of adverse events of tracheal intubation. It is worth promoting in the clinic.