Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction.

IF 2.4 3区 医学 Q2 ORTHOPEDICS
Orthopaedic Journal of Sports Medicine Pub Date : 2025-02-18 eCollection Date: 2025-02-01 DOI:10.1177/23259671251318014
Richard C Lee, Steven D Voinier, Conor F McCarthy, Donald F Colantonio, Shawn M Gee, Christopher J Tucker, Melvin D Helgeson, Nicholas P Lopreiato
{"title":"Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction.","authors":"Richard C Lee, Steven D Voinier, Conor F McCarthy, Donald F Colantonio, Shawn M Gee, Christopher J Tucker, Melvin D Helgeson, Nicholas P Lopreiato","doi":"10.1177/23259671251318014","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established.</p><p><strong>Purpose/hypothesis: </strong>This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft.</p><p><strong>Study design: </strong>Controlled laboratory study.</p><p><strong>Methods: </strong>A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10-mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6-mm wide or 8-mm wide full-thickness QT along with a 10-mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure.</p><p><strong>Results: </strong>The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT (<i>P</i> = .004), 10-mm and 6-mm QT (<i>P</i> < .001), 10-mm QT and 10-mm PT (<i>P</i> < .001), and 8-mm QT and 10-mm PT grafts (<i>P</i> < .001), but not between the 6-mm QT and 10-mm PT grafts (<i>P</i> = .152).</p><p><strong>Conclusion: </strong>The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts <10 mm in width may maintain sufficient tensile strength for ACLR.</p><p><strong>Clinical relevance: </strong>Given these biomechanical properties, smaller QT graft sizes may be advantageous in minimizing arthrofibrosis risk while maintaining graft strength.</p>","PeriodicalId":19646,"journal":{"name":"Orthopaedic Journal of Sports Medicine","volume":"13 2","pages":"23259671251318014"},"PeriodicalIF":2.4000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11833892/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Journal of Sports Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/23259671251318014","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/2/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Despite clinical evidence of risks in knee arthrofibrosis and graft impingement with larger grafts, the optimal size for quadriceps tendon (QT) autografts in anterior cruciate ligament reconstruction (ACLR) has not been established.

Purpose/hypothesis: This study aimed to evaluate the mechanical properties of full-thickness 6-mm and 8-mm wide QT grafts compared with 10-mm patellar tendon (PT) and 10-mm QT grafts. The hypothesis was that both the 6- and 8-mm QT grafts would exhibit similar or superior ultimate tensile strength compared with the 10-mm PT graft.

Study design: Controlled laboratory study.

Methods: A total of 18 matched pairs of cadaveric knees were used in this study. From each pair, a 10-mm wide full-thickness QT was harvested from 1 knee. Based on randomization, a 6-mm wide or 8-mm wide full-thickness QT along with a 10-mm wide PT were harvested from the contralateral knee. Each tendon was clamped, tensioned, and cycled on a servohydraulic testing machine before final loading to failure.

Results: The ultimate failure load was 1286 ± 237.3 N for the 10-mm QT, 1056 ± 226.7 N for the 8-mm QT, 935.1 ± 283.8 N for the 6-mm QT, and 816 ± 192.7 N for the 10-mm PT. Ultimate tensile strength differed significantly between the 10-mm and 8-mm QT (P = .004), 10-mm and 6-mm QT (P < .001), 10-mm QT and 10-mm PT (P < .001), and 8-mm QT and 10-mm PT grafts (P < .001), but not between the 6-mm QT and 10-mm PT grafts (P = .152).

Conclusion: The 8-mm QT had higher ultimate tensile strength than the 10-mm PT, and the 6-mm QT was comparable to the 10-mm PT. Full-thickness QT grafts <10 mm in width may maintain sufficient tensile strength for ACLR.

Clinical relevance: Given these biomechanical properties, smaller QT graft sizes may be advantageous in minimizing arthrofibrosis risk while maintaining graft strength.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Journal of Sports Medicine
Orthopaedic Journal of Sports Medicine Medicine-Orthopedics and Sports Medicine
CiteScore
4.30
自引率
7.70%
发文量
876
审稿时长
12 weeks
期刊介绍: The Orthopaedic Journal of Sports Medicine (OJSM), developed by the American Orthopaedic Society for Sports Medicine (AOSSM), is a global, peer-reviewed, open access journal that combines the interests of researchers and clinical practitioners across orthopaedic sports medicine, arthroscopy, and knee arthroplasty. Topics include original research in the areas of: -Orthopaedic Sports Medicine, including surgical and nonsurgical treatment of orthopaedic sports injuries -Arthroscopic Surgery (Shoulder/Elbow/Wrist/Hip/Knee/Ankle/Foot) -Relevant translational research -Sports traumatology/epidemiology -Knee and shoulder arthroplasty The OJSM also publishes relevant systematic reviews and meta-analyses. This journal is a member of the Committee on Publication Ethics (COPE).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信