Diagnostic Performance of a Type III Portable Monitoring Device for Obstructive Sleep Apnea in Pregnant Women: A Prospective Validation Study.

IF 3 3区 医学 Q1 MEDICINE, GENERAL & INTERNAL
Sofía Romero-Peralta, Miguel Alonso, Olga Mediano, María Cerdà Moncadas, Ainhoa Álvarez Ruiz De Larrinaga, Mercedes Codina Marcet, María Paloma Giménez Carrero, Mónica de la Peña, José Antonio Peña Zarza, Francisco García-Río, Alberto Alonso-Fernández
{"title":"Diagnostic Performance of a Type III Portable Monitoring Device for Obstructive Sleep Apnea in Pregnant Women: A Prospective Validation Study.","authors":"Sofía Romero-Peralta, Miguel Alonso, Olga Mediano, María Cerdà Moncadas, Ainhoa Álvarez Ruiz De Larrinaga, Mercedes Codina Marcet, María Paloma Giménez Carrero, Mónica de la Peña, José Antonio Peña Zarza, Francisco García-Río, Alberto Alonso-Fernández","doi":"10.1089/jwh.2024.1033","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Rationale:</i></b> Obstructive sleep apnea (OSA) during pregnancy is linked to negative maternal and neonatal outcomes. Diagnosing OSA in this population is particularly challenging. Portable monitoring devices (PMD) present a potential alternative to polysomnography (PSG), but their effectiveness in pregnant women is uncertain. <b><i>Objective:</i></b> To evaluate diagnostic accuracy of a PMD to detect OSA in pregnant women. <b><i>Methods:</i></b> A prospective study of 136 middle-aged pregnant women (34 ± 4 years) in their third trimester of pregnancy (34 ± 3 weeks) who underwent laboratory type III PMD and PSG simultaneously. <b><i>Results:</i></b> Using an apnea-hypopnea index (AHI) ≥5 event/h by PSG, OSA was diagnosed in 10.3% of women (mild OSA: 86%; moderate OSA: 14%). An acceptable positive correlation was found between both tests in the AHI (<i>r</i> = 0.787; <i>p</i> < 0.001) and oxygen desaturation index (ODI) (<i>r</i> = 0.806; <i>p</i> < 0.001). The agreement limits between PSG and type III PMD were -4.1 to 5.4 for AHI and -6.0 to 4.5 for ODI. The sensitivity and specificity of type III PMD for an AHI ≥5 events/h were 57.1% and 99.2%, respectively, with a positive predictive value (PPV) of 88.9% and a negative predictive value (NPV) of 95.3%. On a receiver operating characteristic curve, the best cutoff point of AHI by type III PMD to identify OSA according to PSG criteria was 2.25 events/h. The sensibility and specificity for this point were 85.7% and 88.5%, respectively, with a PPV of 46.2% and NPV of 98.2%. <b><i>Conclusions:</i></b> A type III PMD with an AHI cutoff of 5 events/h could be a good alternative for OSA diagnosis in pregnant women. Additionally, an AHI ≥2.25 event/h demonstrates good diagnostic performance, but its low positive predictive value suggests that it is more appropriate as a screening tool. Further studies are needed to validate this sleep study tool in pregnant women, particularly in home settings.</p>","PeriodicalId":17636,"journal":{"name":"Journal of women's health","volume":" ","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of women's health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/jwh.2024.1033","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Rationale: Obstructive sleep apnea (OSA) during pregnancy is linked to negative maternal and neonatal outcomes. Diagnosing OSA in this population is particularly challenging. Portable monitoring devices (PMD) present a potential alternative to polysomnography (PSG), but their effectiveness in pregnant women is uncertain. Objective: To evaluate diagnostic accuracy of a PMD to detect OSA in pregnant women. Methods: A prospective study of 136 middle-aged pregnant women (34 ± 4 years) in their third trimester of pregnancy (34 ± 3 weeks) who underwent laboratory type III PMD and PSG simultaneously. Results: Using an apnea-hypopnea index (AHI) ≥5 event/h by PSG, OSA was diagnosed in 10.3% of women (mild OSA: 86%; moderate OSA: 14%). An acceptable positive correlation was found between both tests in the AHI (r = 0.787; p < 0.001) and oxygen desaturation index (ODI) (r = 0.806; p < 0.001). The agreement limits between PSG and type III PMD were -4.1 to 5.4 for AHI and -6.0 to 4.5 for ODI. The sensitivity and specificity of type III PMD for an AHI ≥5 events/h were 57.1% and 99.2%, respectively, with a positive predictive value (PPV) of 88.9% and a negative predictive value (NPV) of 95.3%. On a receiver operating characteristic curve, the best cutoff point of AHI by type III PMD to identify OSA according to PSG criteria was 2.25 events/h. The sensibility and specificity for this point were 85.7% and 88.5%, respectively, with a PPV of 46.2% and NPV of 98.2%. Conclusions: A type III PMD with an AHI cutoff of 5 events/h could be a good alternative for OSA diagnosis in pregnant women. Additionally, an AHI ≥2.25 event/h demonstrates good diagnostic performance, but its low positive predictive value suggests that it is more appropriate as a screening tool. Further studies are needed to validate this sleep study tool in pregnant women, particularly in home settings.

针对孕妇阻塞性睡眠呼吸暂停的 III 型便携式监测设备的诊断性能:前瞻性验证研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of women's health
Journal of women's health 医学-妇产科学
CiteScore
6.60
自引率
5.70%
发文量
197
审稿时长
2 months
期刊介绍: Journal of Women''s Health is the primary source of information for meeting the challenges of providing optimal health care for women throughout their lifespan. The Journal delivers cutting-edge advancements in diagnostic procedures, therapeutic protocols for the management of diseases, and innovative research in gender-based biology that impacts patient care and treatment. Journal of Women’s Health coverage includes: -Internal Medicine Endocrinology- Cardiology- Oncology- Obstetrics/Gynecology- Urogynecology- Psychiatry- Neurology- Nutrition- Sex-Based Biology- Complementary Medicine- Sports Medicine- Surgery- Medical Education- Public Policy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信