Increasing the number of minor salivary glands from patients with Sjögren's disease improves the diagnostic and measurement precision of the histological focus score.

IF 20.3 1区 医学 Q1 RHEUMATOLOGY
Konstantinos Tryposkiadis, Saba Nayar, Valentina Pucino, Charlotte G Smith, Rachel M Brown, Timothy Bates, Simon J Bowman, Alice Sitch, Malcolm Price, Francesca Barone, Jon Deeks, Benjamin A Fisher
{"title":"Increasing the number of minor salivary glands from patients with Sjögren's disease improves the diagnostic and measurement precision of the histological focus score.","authors":"Konstantinos Tryposkiadis, Saba Nayar, Valentina Pucino, Charlotte G Smith, Rachel M Brown, Timothy Bates, Simon J Bowman, Alice Sitch, Malcolm Price, Francesca Barone, Jon Deeks, Benjamin A Fisher","doi":"10.1016/j.ard.2025.01.038","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Minor salivary gland (MSG) biopsy has an important role in Sjögren's disease diagnosis and research. MSGs show within-patient variation in number of lymphocytic foci per unit area, but the optimal number of MSGs required to balance reproducibility and clinical acceptability has not been determined.</p><p><strong>Methods: </strong>Monte Carlo simulations were performed to investigate impact of MSG number on (i) diagnosis based on focus score (FS) ≥1; (ii) reproducibility, defined as the extent to which 2 FS measurements obtained from 2 within-patient biopsies are the same, assuming no systematic differences have occurred in between biopsies; and (iii) smallest sample size required to detect a clinically meaningful difference in FS. Data simulation was repeated for different MSG numbers (range, 2-7).</p><p><strong>Results: </strong>Higher reproducibility was noted for every unit increase in MSG number, with the median absolute difference between 2 within-patient FS measurements decreasing from 1.05 (SD = 0.25) with 2 glands to 0.52 (SD = 0.12) with 7 glands. MSG number influenced the probability of a simulated patient receiving a FS ≥1, increasing from a median of 0.67 with 2 glands to 0.77 with ≥5 glands. MSG number influenced clinical trial sample sizes. For example, 80% statistical power to detect a 40% FS reduction required a sample size per group of 62 with 2 glands and 25 with 7 glands.</p><p><strong>Conclusions: </strong>For a diagnostic threshold of FS ≥1, a minimum of 5 glands should ideally be targeted. For continuous FS values, a larger number of MSGs (eg, 6) will increase reproducibility further and reduce clinical trial sample size requirements.</p>","PeriodicalId":8087,"journal":{"name":"Annals of the Rheumatic Diseases","volume":" ","pages":""},"PeriodicalIF":20.3000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of the Rheumatic Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ard.2025.01.038","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RHEUMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Minor salivary gland (MSG) biopsy has an important role in Sjögren's disease diagnosis and research. MSGs show within-patient variation in number of lymphocytic foci per unit area, but the optimal number of MSGs required to balance reproducibility and clinical acceptability has not been determined.

Methods: Monte Carlo simulations were performed to investigate impact of MSG number on (i) diagnosis based on focus score (FS) ≥1; (ii) reproducibility, defined as the extent to which 2 FS measurements obtained from 2 within-patient biopsies are the same, assuming no systematic differences have occurred in between biopsies; and (iii) smallest sample size required to detect a clinically meaningful difference in FS. Data simulation was repeated for different MSG numbers (range, 2-7).

Results: Higher reproducibility was noted for every unit increase in MSG number, with the median absolute difference between 2 within-patient FS measurements decreasing from 1.05 (SD = 0.25) with 2 glands to 0.52 (SD = 0.12) with 7 glands. MSG number influenced the probability of a simulated patient receiving a FS ≥1, increasing from a median of 0.67 with 2 glands to 0.77 with ≥5 glands. MSG number influenced clinical trial sample sizes. For example, 80% statistical power to detect a 40% FS reduction required a sample size per group of 62 with 2 glands and 25 with 7 glands.

Conclusions: For a diagnostic threshold of FS ≥1, a minimum of 5 glands should ideally be targeted. For continuous FS values, a larger number of MSGs (eg, 6) will increase reproducibility further and reduce clinical trial sample size requirements.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of the Rheumatic Diseases
Annals of the Rheumatic Diseases 医学-风湿病学
CiteScore
35.00
自引率
9.90%
发文量
3728
审稿时长
1.4 months
期刊介绍: Annals of the Rheumatic Diseases (ARD) is an international peer-reviewed journal covering all aspects of rheumatology, which includes the full spectrum of musculoskeletal conditions, arthritic disease, and connective tissue disorders. ARD publishes basic, clinical, and translational scientific research, including the most important recommendations for the management of various conditions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信