Implementation of Linac-based VMAT total body irradiation technique on Elekta platform using surface-guided radiation therapy

IF 3.3 3区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Magali Sandt , Stéphanie Marcet , Nathalie Guesnel , Line Claude , Isabelle Martel , Marie-Claude Biston
{"title":"Implementation of Linac-based VMAT total body irradiation technique on Elekta platform using surface-guided radiation therapy","authors":"Magali Sandt ,&nbsp;Stéphanie Marcet ,&nbsp;Nathalie Guesnel ,&nbsp;Line Claude ,&nbsp;Isabelle Martel ,&nbsp;Marie-Claude Biston","doi":"10.1016/j.ejmp.2025.104940","DOIUrl":null,"url":null,"abstract":"<div><h3>Background/introduction</h3><div>To present an optimal workflow using a rotatable tabletop and a surface guided radiation therapy (SGRT) system for volumetric modulated arc therapy (VMAT) based total-body irradiation (TBI).</div></div><div><h3>Methods</h3><div>Twenty patients having received either 2 Gy, 8 Gy, or 12 Gy in 2 Gy per fraction were included. They were immobilized using a vacuum cushion and a three-points mask and positioned on a rotatable tabletop. VMAT treatment plans were performed on Monaco 6.1 (Elekta LTD, Stockholm) treatment planning system and then perturbed by applying shifts of 5mm on the isocenters coordinates to evaluate the robustness. Patients were treated on a Synergy or a VersaHD (Elekta LTD, Stockholm) Linac. Pretreatment positioning was performed either with cone-beam CT images combined with surface guided radiation therapy (SGRT) or with SGRT only. During treatment, intra-fraction motion was controlled with SGRT. Dosimetric data, robustness results and sessions duration were collected.</div></div><div><h3>Results</h3><div>In terms of PTV coverage and lung-sparing, all plans met the requirements of the most recent recommendations. The use of 20–30 cm distances between isocenters, and a 90° collimator rotation, enabled to obtain a linear dose gradient between two consecutive beams, which ensured sufficient robustness against 5 mm shifts in isocenter coordinates in all directions. With an average duration of 1 h ± 12 min between the first and last beams, the first sessions were comparable in length to the extended source-to-skin distance technique.</div></div><div><h3>Conclusion</h3><div>Thanks to the rotatable tabletop and to the SGRT system, accurate and secured VMAT-based TBI treatments were performed within a reasonable timeframe, while ensuring patient comfort.</div></div>","PeriodicalId":56092,"journal":{"name":"Physica Medica-European Journal of Medical Physics","volume":"131 ","pages":"Article 104940"},"PeriodicalIF":3.3000,"publicationDate":"2025-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physica Medica-European Journal of Medical Physics","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S112017972500050X","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background/introduction

To present an optimal workflow using a rotatable tabletop and a surface guided radiation therapy (SGRT) system for volumetric modulated arc therapy (VMAT) based total-body irradiation (TBI).

Methods

Twenty patients having received either 2 Gy, 8 Gy, or 12 Gy in 2 Gy per fraction were included. They were immobilized using a vacuum cushion and a three-points mask and positioned on a rotatable tabletop. VMAT treatment plans were performed on Monaco 6.1 (Elekta LTD, Stockholm) treatment planning system and then perturbed by applying shifts of 5mm on the isocenters coordinates to evaluate the robustness. Patients were treated on a Synergy or a VersaHD (Elekta LTD, Stockholm) Linac. Pretreatment positioning was performed either with cone-beam CT images combined with surface guided radiation therapy (SGRT) or with SGRT only. During treatment, intra-fraction motion was controlled with SGRT. Dosimetric data, robustness results and sessions duration were collected.

Results

In terms of PTV coverage and lung-sparing, all plans met the requirements of the most recent recommendations. The use of 20–30 cm distances between isocenters, and a 90° collimator rotation, enabled to obtain a linear dose gradient between two consecutive beams, which ensured sufficient robustness against 5 mm shifts in isocenter coordinates in all directions. With an average duration of 1 h ± 12 min between the first and last beams, the first sessions were comparable in length to the extended source-to-skin distance technique.

Conclusion

Thanks to the rotatable tabletop and to the SGRT system, accurate and secured VMAT-based TBI treatments were performed within a reasonable timeframe, while ensuring patient comfort.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
14.70%
发文量
493
审稿时长
78 days
期刊介绍: Physica Medica, European Journal of Medical Physics, publishing with Elsevier from 2007, provides an international forum for research and reviews on the following main topics: Medical Imaging Radiation Therapy Radiation Protection Measuring Systems and Signal Processing Education and training in Medical Physics Professional issues in Medical Physics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信