Photoplethysmography parameters in monitoring nociception during general anesthesia.

IF 2.3 3区 医学 Q2 ANESTHESIOLOGY
Hua Li, Yingying Tang, Xiaoping Chen, Mengge Zhang, Feng Jiang, Fangfang Zhu, Linghua Xie, Hui Wu, Qi Xu, Qing Chen, Shulan Xie, Ange Dai, Xinzhong Chen
{"title":"Photoplethysmography parameters in monitoring nociception during general anesthesia.","authors":"Hua Li, Yingying Tang, Xiaoping Chen, Mengge Zhang, Feng Jiang, Fangfang Zhu, Linghua Xie, Hui Wu, Qi Xu, Qing Chen, Shulan Xie, Ange Dai, Xinzhong Chen","doi":"10.1186/s12871-025-02932-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Validated monitoring methods for evaluating the balance of nociception and anti-nociception (BNAN) are needed in general anesthesia. This study assessed six photoplethysmography (PPG) parameters, computed from finger photoplethysmographic waveforms in patients undergoing gynecological surgery under general anesthesia.</p><p><strong>Methods: </strong>A total of 20 participants were included, each undergoing general anesthesia with propofol and remifentanil. The same concentration of remifentanil was maintained throughout the experiment, four different intensities of electrical stimulation were administered, and the patient's fingertip PPG was meticulously recorded. PPG data were preprocessed to extract six PPG morphological parameters, and photoplethysmographic amplitude (PPGA), pulse beat interval (PBI), and surgical pleth index (SPI). Receiver operating characteristic (ROC) curves and the Area Under the Curve (AUC) were constructed and calculated to accurately measure its ability to reflect the nociceptive stimulus state. The consistency of different phase parameters at different stimulus intensities was evaluated by calculating the prediction probabilities. All results were compared with those obtained using SPI, PPGA, and PBI.</p><p><strong>Results: </strong>After stimulation, all parameters and SPI showed significant changes compared with those before stimulation (p = 0.000). The catacrotic phase parameters (AC and MHC) showed higher discrimination in adequate analgesia and congruence with electrical stimulation intensity than the overall phase parameters, PPGA, and anacrotic phase parameters (AC: AUC = 0.851, Pk = 0.800; MHC: AUC = 0.837, Pk = 0.792).</p><p><strong>Conclusions: </strong>In this study, six PPG morphological parameters were proposed and observed for the first time to effectively distinguish the occurrence of nociception. Compared with the overall phase parameters, PPGA, and anacrotic phase parameters, catacrotic phase parameters were more capable of characterizing noxious stimuli and more consistent with changes in electrical stimulation intensity.</p><p><strong>Trial registration: </strong>ChiCTR2200062228; Registered at http://clinicaltrials.gov on July 30, 2022.</p>","PeriodicalId":9190,"journal":{"name":"BMC Anesthesiology","volume":"25 1","pages":"78"},"PeriodicalIF":2.3000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11831782/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12871-025-02932-3","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Validated monitoring methods for evaluating the balance of nociception and anti-nociception (BNAN) are needed in general anesthesia. This study assessed six photoplethysmography (PPG) parameters, computed from finger photoplethysmographic waveforms in patients undergoing gynecological surgery under general anesthesia.

Methods: A total of 20 participants were included, each undergoing general anesthesia with propofol and remifentanil. The same concentration of remifentanil was maintained throughout the experiment, four different intensities of electrical stimulation were administered, and the patient's fingertip PPG was meticulously recorded. PPG data were preprocessed to extract six PPG morphological parameters, and photoplethysmographic amplitude (PPGA), pulse beat interval (PBI), and surgical pleth index (SPI). Receiver operating characteristic (ROC) curves and the Area Under the Curve (AUC) were constructed and calculated to accurately measure its ability to reflect the nociceptive stimulus state. The consistency of different phase parameters at different stimulus intensities was evaluated by calculating the prediction probabilities. All results were compared with those obtained using SPI, PPGA, and PBI.

Results: After stimulation, all parameters and SPI showed significant changes compared with those before stimulation (p = 0.000). The catacrotic phase parameters (AC and MHC) showed higher discrimination in adequate analgesia and congruence with electrical stimulation intensity than the overall phase parameters, PPGA, and anacrotic phase parameters (AC: AUC = 0.851, Pk = 0.800; MHC: AUC = 0.837, Pk = 0.792).

Conclusions: In this study, six PPG morphological parameters were proposed and observed for the first time to effectively distinguish the occurrence of nociception. Compared with the overall phase parameters, PPGA, and anacrotic phase parameters, catacrotic phase parameters were more capable of characterizing noxious stimuli and more consistent with changes in electrical stimulation intensity.

Trial registration: ChiCTR2200062228; Registered at http://clinicaltrials.gov on July 30, 2022.

求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Anesthesiology
BMC Anesthesiology ANESTHESIOLOGY-
CiteScore
3.50
自引率
4.50%
发文量
349
审稿时长
>12 weeks
期刊介绍: BMC Anesthesiology is an open access, peer-reviewed journal that considers articles on all aspects of anesthesiology, critical care, perioperative care and pain management, including clinical and experimental research into anesthetic mechanisms, administration and efficacy, technology and monitoring, and associated economic issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信