Comparative Assessment of Agreement in Uniformity Analyses across Quality Control Software Platforms.

IF 0.6 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
World Journal of Nuclear Medicine Pub Date : 2024-11-19 eCollection Date: 2025-03-01 DOI:10.1055/s-0044-1795102
Thasmeera T Supramaniam, Muhammad Y Udin, Marianie Musarudin
{"title":"Comparative Assessment of Agreement in Uniformity Analyses across Quality Control Software Platforms.","authors":"Thasmeera T Supramaniam, Muhammad Y Udin, Marianie Musarudin","doi":"10.1055/s-0044-1795102","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective</b>  In nuclear medicine, quality control (QC) activities adhere to international standards, yet their complexity can pose challenges. Gamma camera manufacturers have introduced integrated QC software, offering instantaneous results. However, the agreement of these automated processes with established protocols remains uncertain. This study aims to clarify this uncertainty by comparatively analyzing uniformity from various software solutions for a dual-head gamma camera. <b>Methods</b>  The study utilized integrated QC analysis software and three free QC analysis tools (IAEA-NMQC Toolkit, NM Toolkit, and Fiji) for uniformity analyses. Following the National Electrical Manufacturers Association standards, NEMA Standards Publication NU 1-2018, the intrinsic uniformity test was performed on a GE Discovery NM/CT 670 Pro system. Ten uniformity QC images underwent analysis with both integrated QC software and alternative software. Data agreements were tested using the Blant-Altman regression-based analysis. <b>Results</b>  Significant differences were observed in integral and differential uniformities ( <i>p</i>  < 0.001). The central field of view (useful field of view) integral uniformity mean differences for NMQC Toolkit, NM Toolkit, and Fiji were 2.46% (2.34%), 2.44% (2.31%), and 2.56% (2.64%), respectively. Conversely, x-differential and y-differential uniformity mean differences were consistently under 2%. Regression-based analysis confirmed good agreement between computed values. <b>Conclusion</b>  The integrated QC software of Discovery NM/CT 670 Pro provides reliable uniformity analysis, aligned with the NEMA standards. Variations in computed values may stem from differences in pixel values and applied data corrections.</p>","PeriodicalId":23742,"journal":{"name":"World Journal of Nuclear Medicine","volume":"24 1","pages":"47-56"},"PeriodicalIF":0.6000,"publicationDate":"2024-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11828643/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1795102","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/3/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objective  In nuclear medicine, quality control (QC) activities adhere to international standards, yet their complexity can pose challenges. Gamma camera manufacturers have introduced integrated QC software, offering instantaneous results. However, the agreement of these automated processes with established protocols remains uncertain. This study aims to clarify this uncertainty by comparatively analyzing uniformity from various software solutions for a dual-head gamma camera. Methods  The study utilized integrated QC analysis software and three free QC analysis tools (IAEA-NMQC Toolkit, NM Toolkit, and Fiji) for uniformity analyses. Following the National Electrical Manufacturers Association standards, NEMA Standards Publication NU 1-2018, the intrinsic uniformity test was performed on a GE Discovery NM/CT 670 Pro system. Ten uniformity QC images underwent analysis with both integrated QC software and alternative software. Data agreements were tested using the Blant-Altman regression-based analysis. Results  Significant differences were observed in integral and differential uniformities ( p  < 0.001). The central field of view (useful field of view) integral uniformity mean differences for NMQC Toolkit, NM Toolkit, and Fiji were 2.46% (2.34%), 2.44% (2.31%), and 2.56% (2.64%), respectively. Conversely, x-differential and y-differential uniformity mean differences were consistently under 2%. Regression-based analysis confirmed good agreement between computed values. Conclusion  The integrated QC software of Discovery NM/CT 670 Pro provides reliable uniformity analysis, aligned with the NEMA standards. Variations in computed values may stem from differences in pixel values and applied data corrections.

求助全文
约1分钟内获得全文 求助全文
来源期刊
World Journal of Nuclear Medicine
World Journal of Nuclear Medicine RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
16.70%
发文量
118
审稿时长
48 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信