{"title":"Transoesophageal echocardiography in diagnosing pulmonary arteriovenous malformation.","authors":"Tatsuro Shoji, Masaki Izumo, Yasuhiro Tanabe, Yoshihiro Akashi","doi":"10.1136/bcr-2024-264180","DOIUrl":null,"url":null,"abstract":"<p><p>Pulmonary arteriovenous malformation (PAVM) is a rare cause of embolic stroke of undetermined source (ESUS) and can be challenging to diagnose promptly. In this case, a woman in her 40s with ESUS was diagnosed with PAVM after a transoesophageal echocardiography (TOE) microbubble test revealed bubbles flowing from the right superior pulmonary vein. Endovascular treatment was performed, and follow-up transthoracic echocardiography showed no right-to-left shunt, confirming successful shunt closure. This case is significant as it is the first reported instance where both treatment and postoperative evaluation of PAVM were conducted using echocardiography. The early detection of the shunt through the microbubble test, within three cardiac cycles, was crucial and differs from typical delayed shunt detection. This suggests that focused imaging during TOE can enhance diagnostic accuracy for PAVM.</p>","PeriodicalId":9080,"journal":{"name":"BMJ Case Reports","volume":"18 2","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2025-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/bcr-2024-264180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Pulmonary arteriovenous malformation (PAVM) is a rare cause of embolic stroke of undetermined source (ESUS) and can be challenging to diagnose promptly. In this case, a woman in her 40s with ESUS was diagnosed with PAVM after a transoesophageal echocardiography (TOE) microbubble test revealed bubbles flowing from the right superior pulmonary vein. Endovascular treatment was performed, and follow-up transthoracic echocardiography showed no right-to-left shunt, confirming successful shunt closure. This case is significant as it is the first reported instance where both treatment and postoperative evaluation of PAVM were conducted using echocardiography. The early detection of the shunt through the microbubble test, within three cardiac cycles, was crucial and differs from typical delayed shunt detection. This suggests that focused imaging during TOE can enhance diagnostic accuracy for PAVM.
期刊介绍:
BMJ Case Reports is an important educational resource offering a high volume of cases in all disciplines so that healthcare professionals, researchers and others can easily find clinically important information on common and rare conditions. All articles are peer reviewed and copy edited before publication. BMJ Case Reports is not an edition or supplement of the BMJ.