Artificial intelligence in corticospinal tract segmentation using constrained spherical deconvolution.

Surgical neurology international Pub Date : 2025-01-31 eCollection Date: 2025-01-01 DOI:10.25259/SNI_982_2024
Erom Lucas Alves Freitas, Bruno Fernandes de Oliveira Santos
{"title":"Artificial intelligence in corticospinal tract segmentation using constrained spherical deconvolution.","authors":"Erom Lucas Alves Freitas, Bruno Fernandes de Oliveira Santos","doi":"10.25259/SNI_982_2024","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Tractography of cerebral white matter tracts is a technique with applications in neurosurgical planning and the diagnosis of neurological diseases. In this context, the approach based on the constrained spherical deconvolution (CSD) algorithm allows for more efficient and plausible segmentations. This study aimed to compare two CSD techniques for corticospinal tract (CST) segmentation.</p><p><strong>Methods: </strong>This study examined 40 diffusion-weighted images (DWIs) acquired at 7T from healthy participants in the human connectome project (HCP) and 12 clinical 1.5T DWIs from patients undergoing neurosurgical procedures. Tractography was performed using two techniques: regions of interest-based approach and an automatic approach using the TractSeg neural network. The volume of the CST segmented by the two methods was compared using the Dice similarity coefficient.</p><p><strong>Results: </strong>There was a low similarity between the CST volumes segmented by the two techniques (Dice index for the HCP: 0.479 ± 0.04; Dice index for the Clinical: 0.404 ± 0.08). However, both techniques achieved high levels of consistency in sequential measurements, with intraclass correlation coefficient values above 0.995 for all comparisons. In addition, all selected metrics showed significant differences when comparing the two techniques (HCP - volume <i>P</i> < 0.0001, fractional anisotropy [FA] <i>P</i> = 0.0061, mean diffusivity [MD] <i>P</i> < 0.0001; Clinical - volume <i>P</i> < 0.0001, FA <i>P</i> = 0.0018, MD <i>P</i> = 0.0018).</p><p><strong>Conclusion: </strong>Both methods demonstrate a high degree of consistency; however, the automatic approach appears to be more consistent overall. When comparing the CST segmentations between the two methods, we observed only a moderate similarity and differences in all considered metrics.</p>","PeriodicalId":94217,"journal":{"name":"Surgical neurology international","volume":"16 ","pages":"32"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11799708/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical neurology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/SNI_982_2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Tractography of cerebral white matter tracts is a technique with applications in neurosurgical planning and the diagnosis of neurological diseases. In this context, the approach based on the constrained spherical deconvolution (CSD) algorithm allows for more efficient and plausible segmentations. This study aimed to compare two CSD techniques for corticospinal tract (CST) segmentation.

Methods: This study examined 40 diffusion-weighted images (DWIs) acquired at 7T from healthy participants in the human connectome project (HCP) and 12 clinical 1.5T DWIs from patients undergoing neurosurgical procedures. Tractography was performed using two techniques: regions of interest-based approach and an automatic approach using the TractSeg neural network. The volume of the CST segmented by the two methods was compared using the Dice similarity coefficient.

Results: There was a low similarity between the CST volumes segmented by the two techniques (Dice index for the HCP: 0.479 ± 0.04; Dice index for the Clinical: 0.404 ± 0.08). However, both techniques achieved high levels of consistency in sequential measurements, with intraclass correlation coefficient values above 0.995 for all comparisons. In addition, all selected metrics showed significant differences when comparing the two techniques (HCP - volume P < 0.0001, fractional anisotropy [FA] P = 0.0061, mean diffusivity [MD] P < 0.0001; Clinical - volume P < 0.0001, FA P = 0.0018, MD P = 0.0018).

Conclusion: Both methods demonstrate a high degree of consistency; however, the automatic approach appears to be more consistent overall. When comparing the CST segmentations between the two methods, we observed only a moderate similarity and differences in all considered metrics.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信