Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient-reported outcomes and retear rate at 1 year.

IF 1.5 Q3 ORTHOPEDICS
Joshua P Castle, Johnny K Kasto, Eric X Jiang, Michael A Gaudiani, Trevor D Wolterink, Taylor Timoteo, Jacob Best, Shariff K Bishai, Patricia A Kolowich, Stephanie J Muh
{"title":"Arthroscopic rotator cuff repair with bioinductive patch achieves equivalent patient-reported outcomes and retear rate at 1 year.","authors":"Joshua P Castle, Johnny K Kasto, Eric X Jiang, Michael A Gaudiani, Trevor D Wolterink, Taylor Timoteo, Jacob Best, Shariff K Bishai, Patricia A Kolowich, Stephanie J Muh","doi":"10.1177/17585732251317954","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to evaluate the safety and efficacy of a bioinductive patch augmentation following arthroscopic rotator cuff repair (RCR) in terms of patient-reported outcomes, motion, and complications stratified by tear size.</p><p><strong>Methods: </strong>A retrospective review of patients undergoing primary RCR with and without bioinductive bovine collagen patch augmentation for supraspinatus/infraspinatus tears from 2014 to 2022 at two centers was performed. Exclusion criteria included: age <18 years, revisions, or lack of 6-month postoperative follow-up. Patients were propensity-score matched 2:1 to patch-augmented patients based on age, sex, BMI, and tear size. Outcomes were compared between the patch and control groups after being stratified by tear size.</p><p><strong>Results: </strong>A total of 125 patients patch augmented RCRs were matched to 250 controls. No significant differences in demographics or comorbidities between groups. Following stratification by tear size, VAS for partial and small/medium tears in the patch cohorts were lower (<i>p</i> = 0.02) at 3 months. Functional scores were not statistically different. Patch-augmented partial and small/medium tears showed increased forward elevation (<i>p</i> < 0.05) at 1-year follow-up. Retear rates were statistically similar.</p><p><strong>Conclusions: </strong>Bioinductive patch augmentation demonstrates equivalent outcomes for pain and function, retear rate, but is associated with improved forward elevation up to 1-year for partial and small/medium tears.</p><p><strong>Level of evidence: </strong>Level III, retrospective cohort study.</p>","PeriodicalId":36705,"journal":{"name":"Shoulder and Elbow","volume":" ","pages":"17585732251317954"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11803597/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shoulder and Elbow","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/17585732251317954","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this study was to evaluate the safety and efficacy of a bioinductive patch augmentation following arthroscopic rotator cuff repair (RCR) in terms of patient-reported outcomes, motion, and complications stratified by tear size.

Methods: A retrospective review of patients undergoing primary RCR with and without bioinductive bovine collagen patch augmentation for supraspinatus/infraspinatus tears from 2014 to 2022 at two centers was performed. Exclusion criteria included: age <18 years, revisions, or lack of 6-month postoperative follow-up. Patients were propensity-score matched 2:1 to patch-augmented patients based on age, sex, BMI, and tear size. Outcomes were compared between the patch and control groups after being stratified by tear size.

Results: A total of 125 patients patch augmented RCRs were matched to 250 controls. No significant differences in demographics or comorbidities between groups. Following stratification by tear size, VAS for partial and small/medium tears in the patch cohorts were lower (p = 0.02) at 3 months. Functional scores were not statistically different. Patch-augmented partial and small/medium tears showed increased forward elevation (p < 0.05) at 1-year follow-up. Retear rates were statistically similar.

Conclusions: Bioinductive patch augmentation demonstrates equivalent outcomes for pain and function, retear rate, but is associated with improved forward elevation up to 1-year for partial and small/medium tears.

Level of evidence: Level III, retrospective cohort study.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Shoulder and Elbow
Shoulder and Elbow Medicine-Rehabilitation
CiteScore
2.80
自引率
0.00%
发文量
91
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信