[Assessment of Radiation Dose Reduction for Medical Staff at the Patient's Head Side in Structural Heart Disease Intervention Using Protective Equipment].

Hirotoshi Murakami, Naoki Hosoda, Natsuki Oyama, Ryoya Hatsuoka, Itaru Sudo
{"title":"[Assessment of Radiation Dose Reduction for Medical Staff at the Patient's Head Side in Structural Heart Disease Intervention Using Protective Equipment].","authors":"Hirotoshi Murakami, Naoki Hosoda, Natsuki Oyama, Ryoya Hatsuoka, Itaru Sudo","doi":"10.6009/jjrt.25-1505","DOIUrl":null,"url":null,"abstract":"<p><p>In interventions for structural heart disease (SHD), an echocardiologist and an anesthesiologist are also present close to the side of the bed at the patient's head. The purpose of this study was to investigate the effectiveness of X-ray protective devices in reducing exposure to scatter radiation for medical staff at the side of the head end of the angiography system bed during interventions for structural heart disease. The ambient radiation dosage was measured, with and without X-ray protective equipment, to determine the rate of reduction of scatter radiation. The dosage tended to be higher at the working angle compared to the PA direction. When protective equipment was not used, the dosage tended to be higher at the side of the head end of the bed than at the operator's position. The dose was reduced by more than 90% compared to that without protective equipment by installing a protective device at the side of the head end of the bed. It is important to understand the spatial dose distribution at the working angle, and the installation of protective equipment at the side of the head end of the bed during SHD interventions can reduce the exposure of attending staff.</p>","PeriodicalId":74309,"journal":{"name":"Nihon Hoshasen Gijutsu Gakkai zasshi","volume":"81 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Hoshasen Gijutsu Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6009/jjrt.25-1505","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In interventions for structural heart disease (SHD), an echocardiologist and an anesthesiologist are also present close to the side of the bed at the patient's head. The purpose of this study was to investigate the effectiveness of X-ray protective devices in reducing exposure to scatter radiation for medical staff at the side of the head end of the angiography system bed during interventions for structural heart disease. The ambient radiation dosage was measured, with and without X-ray protective equipment, to determine the rate of reduction of scatter radiation. The dosage tended to be higher at the working angle compared to the PA direction. When protective equipment was not used, the dosage tended to be higher at the side of the head end of the bed than at the operator's position. The dose was reduced by more than 90% compared to that without protective equipment by installing a protective device at the side of the head end of the bed. It is important to understand the spatial dose distribution at the working angle, and the installation of protective equipment at the side of the head end of the bed during SHD interventions can reduce the exposure of attending staff.

求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信