Distribution analysis of structural properties of native porcine humerus–rotator cuff–scapular complex using universal testing machine

IF 2 Q2 ORTHOPEDICS
Tsuneari Takahashi, Hideyuki Sasanuma, Katsushi Takeshita
{"title":"Distribution analysis of structural properties of native porcine humerus–rotator cuff–scapular complex using universal testing machine","authors":"Tsuneari Takahashi,&nbsp;Hideyuki Sasanuma,&nbsp;Katsushi Takeshita","doi":"10.1002/jeo2.70164","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>This study aimed to evaluate the effectiveness of an original mechanical testing setup including the humerus, myotendinous junction and scapula designed to assess the structural properties of rotator cuff attachments in large animals and determine optimal conditions.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Eight domestic pigs (age, 4–6 months; weight, 30–52 kg) without genetic modifications were euthanized under intubated general anaesthesia control. The scapula–supraspinatus tendon complex with the humerus was excised as a single unit. A device was developed on a universal testing machine to pull in the direction of the tendon's path. After preconditioning at 5 N for 30 s, the composite was stretched to failure at 50 mm/min, and the failure mode was observed. The normality of each structural property was evaluated using the Shapiro–Wilk test. Student's <i>t</i> test or the Mann–Whitney U-test was used to compare whether the structural properties vary in failure modes.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Nine shoulders (56%) ruptured at the humeral attachment; in the remaining seven, the tendon was pulled out from the scapula, leading to rupture. The maximum load and elongation at failure showed normality, whereas the yield load and linear stiffness did not show normality. The mean (standard deviation) maximum load and elongation at failure were 346.4 (99.2) N and 43.1 (12.2) mm, respectively. The median (first and third quartiles) yield load and linear stiffness were 81.2 (63.0, 121.6) N and 15.8 (14.8, 17.5) N/mm, respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>This mechanical testing system is useful for evaluating the structural properties of porcine rotator cuff attachments and should be additionally evaluated by cyclic testing.</p>\n </section>\n \n <section>\n \n <h3> Level of Evidence</h3>\n \n <p>Level IV.</p>\n </section>\n </div>","PeriodicalId":36909,"journal":{"name":"Journal of Experimental Orthopaedics","volume":"12 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jeo2.70164","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Experimental Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

This study aimed to evaluate the effectiveness of an original mechanical testing setup including the humerus, myotendinous junction and scapula designed to assess the structural properties of rotator cuff attachments in large animals and determine optimal conditions.

Methods

Eight domestic pigs (age, 4–6 months; weight, 30–52 kg) without genetic modifications were euthanized under intubated general anaesthesia control. The scapula–supraspinatus tendon complex with the humerus was excised as a single unit. A device was developed on a universal testing machine to pull in the direction of the tendon's path. After preconditioning at 5 N for 30 s, the composite was stretched to failure at 50 mm/min, and the failure mode was observed. The normality of each structural property was evaluated using the Shapiro–Wilk test. Student's t test or the Mann–Whitney U-test was used to compare whether the structural properties vary in failure modes.

Results

Nine shoulders (56%) ruptured at the humeral attachment; in the remaining seven, the tendon was pulled out from the scapula, leading to rupture. The maximum load and elongation at failure showed normality, whereas the yield load and linear stiffness did not show normality. The mean (standard deviation) maximum load and elongation at failure were 346.4 (99.2) N and 43.1 (12.2) mm, respectively. The median (first and third quartiles) yield load and linear stiffness were 81.2 (63.0, 121.6) N and 15.8 (14.8, 17.5) N/mm, respectively.

Conclusion

This mechanical testing system is useful for evaluating the structural properties of porcine rotator cuff attachments and should be additionally evaluated by cyclic testing.

Level of Evidence

Level IV.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics Medicine-Orthopedics and Sports Medicine
CiteScore
3.20
自引率
5.60%
发文量
114
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信