{"title":"Sandwich technique for endovascular repair of type A aortic dissection following stent graft with an inner branch in the ascending aorta","authors":"Kosuke Ujihira MD, Reiko Kemmochi MD, Taiichiro Matsumoto MD, Noriyuki Tokunaga MD, PhD, Mitsuaki Matsumoto MD, PhD","doi":"10.1016/j.jvscit.2025.101735","DOIUrl":null,"url":null,"abstract":"<div><div>Type A aortic dissection after thoracic endovascular aortic repair is a life-threatening complication. We present a case of acute type A aortic dissection that occurred after zone 0 stent grafting with a physician-modified inner branch in the ascending aorta. We performed additional endovascular aortic repair using the sandwich technique, which involved placing a chimney stent graft for the brachiocephalic artery and a main aortic stent graft covered by a shortened outer stent graft in the ascending aorta. This technique minimized device diameter, preventing over-dilatation of the true lumen, with sufficient overlap of the stent grafts.</div></div>","PeriodicalId":45071,"journal":{"name":"Journal of Vascular Surgery Cases Innovations and Techniques","volume":"11 2","pages":"Article 101735"},"PeriodicalIF":0.7000,"publicationDate":"2025-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vascular Surgery Cases Innovations and Techniques","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468428725000176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Type A aortic dissection after thoracic endovascular aortic repair is a life-threatening complication. We present a case of acute type A aortic dissection that occurred after zone 0 stent grafting with a physician-modified inner branch in the ascending aorta. We performed additional endovascular aortic repair using the sandwich technique, which involved placing a chimney stent graft for the brachiocephalic artery and a main aortic stent graft covered by a shortened outer stent graft in the ascending aorta. This technique minimized device diameter, preventing over-dilatation of the true lumen, with sufficient overlap of the stent grafts.
期刊介绍:
Journal of Vascular Surgery Cases and Innovative Techniques is a surgical journal dedicated to publishing peer review high quality case reports, vascular images and innovative techniques related to all aspects of arterial, venous, and lymphatic diseases and disorders, including vascular trauma, malformations, wound care and the placement and maintenance of arterio-venous dialysis accesses with an emphasis on the practicing clinician. The Journal seeks to provide novel and timely information to vascular surgeons, interventionalists, phlebologists, wound care specialists, and allied health professionals involved with the management of patients with the entire spectrum of vascular disorders.