Advanced thyristor-based cycloconverter for efficient three-phase conversion with low THD

Mahbubur Rahman Tahmid , Md. Abdul Malek , Md. Rafiul Islam , Muhammad Abdul Goffar Khan
{"title":"Advanced thyristor-based cycloconverter for efficient three-phase conversion with low THD","authors":"Mahbubur Rahman Tahmid ,&nbsp;Md. Abdul Malek ,&nbsp;Md. Rafiul Islam ,&nbsp;Muhammad Abdul Goffar Khan","doi":"10.1016/j.prime.2025.100918","DOIUrl":null,"url":null,"abstract":"<div><div>The growing demand for sustainable systems capable of serving three-phase loads from a single-phase grid has spurred significant research. Conventional DC-link-based single-phase to three-phase converters and variable frequency drives require massive and expensive processing units. Additionally, they have a high conduction loss as they involve multiple conversion stages. Similarly, traditional single-phase to three-phase cycloconverters suffer from excessive harmonic distortion in the output voltage and current. This article proposes a new single-phase to three-phase cycloconverter to reduce harmonics of the output voltage. This design employs a Specially-tapped Single-phase Transformer (STSPT), in which the secondary side of the transformer has 4 extra taps to create multiple voltage levels of sinusoidal pulses. These taps are placed according to calculations and simulations, which enabling frequency and phase conversion using only a single conversion stage with a reduced THD. Detailed analysis is presented, including its response to variable output frequency settings such as 16.67 Hz, 12.5 Hz, 10 Hz, and 8.33 Hz with resistive and motor loads. Multiple voltage levels of sinusoidal pulses in the output signal theoretically reduce the THD by up to 20% compared to conventional designs. A prototype of the cycloconverter was developed and the experimental results confirm close agreement with the theoretical predictions, demonstrating a THD reduction of up to 19% in the output voltage and current compared to conventional models, which makes it a reliable system to drive three-phase loads from a single-phase supply.</div></div>","PeriodicalId":100488,"journal":{"name":"e-Prime - Advances in Electrical Engineering, Electronics and Energy","volume":"11 ","pages":"Article 100918"},"PeriodicalIF":0.0000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"e-Prime - Advances in Electrical Engineering, Electronics and Energy","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772671125000257","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The growing demand for sustainable systems capable of serving three-phase loads from a single-phase grid has spurred significant research. Conventional DC-link-based single-phase to three-phase converters and variable frequency drives require massive and expensive processing units. Additionally, they have a high conduction loss as they involve multiple conversion stages. Similarly, traditional single-phase to three-phase cycloconverters suffer from excessive harmonic distortion in the output voltage and current. This article proposes a new single-phase to three-phase cycloconverter to reduce harmonics of the output voltage. This design employs a Specially-tapped Single-phase Transformer (STSPT), in which the secondary side of the transformer has 4 extra taps to create multiple voltage levels of sinusoidal pulses. These taps are placed according to calculations and simulations, which enabling frequency and phase conversion using only a single conversion stage with a reduced THD. Detailed analysis is presented, including its response to variable output frequency settings such as 16.67 Hz, 12.5 Hz, 10 Hz, and 8.33 Hz with resistive and motor loads. Multiple voltage levels of sinusoidal pulses in the output signal theoretically reduce the THD by up to 20% compared to conventional designs. A prototype of the cycloconverter was developed and the experimental results confirm close agreement with the theoretical predictions, demonstrating a THD reduction of up to 19% in the output voltage and current compared to conventional models, which makes it a reliable system to drive three-phase loads from a single-phase supply.
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信