Dielectric blood coagulometry to evaluate coagulation activity in patients prescribed factor Xa inhibitors undergoing elective surgery: A prospective observational study

IF 3.7 3区 医学 Q1 HEMATOLOGY
Aya Takemoto , Nobuyo Kondo , Akiko Kitajo , Hiroto Yamamoto , Yudai Yamamoto , Koji Higashino , Tokujiro Uchida
{"title":"Dielectric blood coagulometry to evaluate coagulation activity in patients prescribed factor Xa inhibitors undergoing elective surgery: A prospective observational study","authors":"Aya Takemoto ,&nbsp;Nobuyo Kondo ,&nbsp;Akiko Kitajo ,&nbsp;Hiroto Yamamoto ,&nbsp;Yudai Yamamoto ,&nbsp;Koji Higashino ,&nbsp;Tokujiro Uchida","doi":"10.1016/j.thromres.2025.109283","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Dielectric blood coagulometry (DBCM) is a coagulation test based on dielectric permittivity. We recently developed a new cartridge to evaluate the anticoagulation effect of factor Xa inhibitors and investigated the usefulness of this system in the clinical setting. Here, we evaluate the relationship among the coagulation time measured by DBCM, plasma concentrations of factor Xa inhibitors, and peak thrombin generation using blood samples from patients prescribed factor Xa inhibitors undergoing elective surgery.</div></div><div><h3>Methods</h3><div>Whole-blood samples were collected at the preoperative visit and after anesthetic induction in the operating room, and our cartridge was used to measure the coagulation time by DBCM. Plasma was used to evaluate thrombin generation and to perform in vitro quantification of factor Xa inhibitors. Spearman's correlation was used to analyze correlations, and receiver operating characteristic (ROC) curves were used to evaluate diagnostic performance.</div></div><div><h3>Results</h3><div>The DBCM coagulation time correlated with plasma factor Xa inhibitor concentrations (Rs = 0.87 for apixaban [<em>n</em> = 57, <em>P</em> &lt; 0.001]; Rs = 0.91 for rivaroxaban [<em>n</em> = 49, <em>P</em> &lt; 0.001]) and peak thrombin generation (Rs = −0.80 for apixaban [<em>n</em> = 57, <em>P</em> &lt; 0.001]; Rs = −0.84 for rivaroxaban [<em>n</em> = 49, P &lt; 0.001]). Samples with factor Xa inhibitor concentrations &lt;30 ng/mL had an area under the ROC curve of 0.98 (95 % confidence interval 0.96–1.0) for apixaban and 0.99 (95 % confidence interval 0.99–1.0) for rivaroxaban.</div></div><div><h3>Conclusions</h3><div>DBCM was a useful point-of-care test to evaluate the anticoagulation effect induced by factor Xa inhibitors.</div></div>","PeriodicalId":23064,"journal":{"name":"Thrombosis research","volume":"247 ","pages":"Article 109283"},"PeriodicalIF":3.7000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thrombosis research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0049384825000325","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Dielectric blood coagulometry (DBCM) is a coagulation test based on dielectric permittivity. We recently developed a new cartridge to evaluate the anticoagulation effect of factor Xa inhibitors and investigated the usefulness of this system in the clinical setting. Here, we evaluate the relationship among the coagulation time measured by DBCM, plasma concentrations of factor Xa inhibitors, and peak thrombin generation using blood samples from patients prescribed factor Xa inhibitors undergoing elective surgery.

Methods

Whole-blood samples were collected at the preoperative visit and after anesthetic induction in the operating room, and our cartridge was used to measure the coagulation time by DBCM. Plasma was used to evaluate thrombin generation and to perform in vitro quantification of factor Xa inhibitors. Spearman's correlation was used to analyze correlations, and receiver operating characteristic (ROC) curves were used to evaluate diagnostic performance.

Results

The DBCM coagulation time correlated with plasma factor Xa inhibitor concentrations (Rs = 0.87 for apixaban [n = 57, P < 0.001]; Rs = 0.91 for rivaroxaban [n = 49, P < 0.001]) and peak thrombin generation (Rs = −0.80 for apixaban [n = 57, P < 0.001]; Rs = −0.84 for rivaroxaban [n = 49, P < 0.001]). Samples with factor Xa inhibitor concentrations <30 ng/mL had an area under the ROC curve of 0.98 (95 % confidence interval 0.96–1.0) for apixaban and 0.99 (95 % confidence interval 0.99–1.0) for rivaroxaban.

Conclusions

DBCM was a useful point-of-care test to evaluate the anticoagulation effect induced by factor Xa inhibitors.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Thrombosis research
Thrombosis research 医学-外周血管病
CiteScore
14.60
自引率
4.00%
发文量
364
审稿时长
31 days
期刊介绍: Thrombosis Research is an international journal dedicated to the swift dissemination of new information on thrombosis, hemostasis, and vascular biology, aimed at advancing both science and clinical care. The journal publishes peer-reviewed original research, reviews, editorials, opinions, and critiques, covering both basic and clinical studies. Priority is given to research that promises novel approaches in the diagnosis, therapy, prognosis, and prevention of thrombotic and hemorrhagic diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信