{"title":"A deep learning-driven method for safe and effective ERCP cannulation.","authors":"Yuying Liu, Xin Chen, Siyang Zuo","doi":"10.1007/s11548-025-03329-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In recent years, the detection of the duodenal papilla and surgical cannula has become a critical task in computer-assisted endoscopic retrograde cholangiopancreatography (ERCP) cannulation operations. The complex surgical anatomy, coupled with the small size of the duodenal papillary orifice and its high similarity to the background, poses significant challenges to effective computer-assisted cannulation. To address these challenges, we present a deep learning-driven graphical user interface (GUI) to assist ERCP cannulation.</p><p><strong>Methods: </strong>Considering the characteristics of the ERCP scenario, we propose a deep learning method for duodenal papilla and surgical cannula detection, utilizing four swin transformer decoupled heads (4STDH). Four different prediction heads are employed to detect objects of different sizes. Subsequently, we integrate the swin transformer module to identify attention regions to explore prediction potential deeply. Moreover, we decouple the classification and regression networks, significantly improving the model's accuracy and robustness through the separation prediction. Simultaneously, we introduce a dataset on papilla and cannula (DPAC), consisting of 1840 annotated endoscopic images, which will be publicly available. We integrated 4STDH and several state-of-the-art methods into the GUI and compared them.</p><p><strong>Results: </strong>On the DPAC dataset, 4STDH outperforms state-of-the-art methods with an mAP of 93.2% and superior generalization performance. Additionally, the GUI provides real-time positions of the papilla and cannula, along with the planar distance and direction required for the cannula to reach the cannulation position.</p><p><strong>Conclusion: </strong>We validate the GUI's performance in human gastrointestinal endoscopic videos, showing deep learning's potential to enhance the safety and efficiency of clinical ERCP cannulation.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2025-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-025-03329-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: In recent years, the detection of the duodenal papilla and surgical cannula has become a critical task in computer-assisted endoscopic retrograde cholangiopancreatography (ERCP) cannulation operations. The complex surgical anatomy, coupled with the small size of the duodenal papillary orifice and its high similarity to the background, poses significant challenges to effective computer-assisted cannulation. To address these challenges, we present a deep learning-driven graphical user interface (GUI) to assist ERCP cannulation.

Methods: Considering the characteristics of the ERCP scenario, we propose a deep learning method for duodenal papilla and surgical cannula detection, utilizing four swin transformer decoupled heads (4STDH). Four different prediction heads are employed to detect objects of different sizes. Subsequently, we integrate the swin transformer module to identify attention regions to explore prediction potential deeply. Moreover, we decouple the classification and regression networks, significantly improving the model's accuracy and robustness through the separation prediction. Simultaneously, we introduce a dataset on papilla and cannula (DPAC), consisting of 1840 annotated endoscopic images, which will be publicly available. We integrated 4STDH and several state-of-the-art methods into the GUI and compared them.

Results: On the DPAC dataset, 4STDH outperforms state-of-the-art methods with an mAP of 93.2% and superior generalization performance. Additionally, the GUI provides real-time positions of the papilla and cannula, along with the planar distance and direction required for the cannula to reach the cannulation position.

Conclusion: We validate the GUI's performance in human gastrointestinal endoscopic videos, showing deep learning's potential to enhance the safety and efficiency of clinical ERCP cannulation.

求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信