Performance of Shock Index as a predictor of severe postpartum hemorrhage following cesarean section under spinal anesthesia: a retrospective cohort study.
Valentina DE Giorgis, Myriam Brebion, Lauranne Ossé, Xavier Repessé, Ann-Marie Crowe, Gilles Orliaguet, Hawa Keita
{"title":"Performance of Shock Index as a predictor of severe postpartum hemorrhage following cesarean section under spinal anesthesia: a retrospective cohort study.","authors":"Valentina DE Giorgis, Myriam Brebion, Lauranne Ossé, Xavier Repessé, Ann-Marie Crowe, Gilles Orliaguet, Hawa Keita","doi":"10.23736/S0375-9393.24.18468-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>An early diagnosis of a postpartum hemorrhage (PPH) can be challenging. The Shock Index (SI), the ratio of heart rate to systolic blood pressure, appears to be a useful indicator for the early diagnosis of severe PPH after vaginal delivery. Our primary aim was to evaluate if the SI has a predictive value for severe PPH following cesarean section (C-section) under spinal anesthesia (SA) and its best predictive threshold.</p><p><strong>Methods: </strong>Retrospective single-center trial including women scheduled for C-section under SA with prevention of maternal hypotension by phenylephrine, and complicated by PPH between 2019 and 2021. Women were divided into two groups: non-severe PPH (blood loss <1000 mL) versus severe PPH (blood loss ≥1000 mL). SI was calculated and compared between the groups at four different time points: T0: prior to C-section; T1: at incision; T2: 15 minutes from start of PPH; T3: end of PPH management. Using receiver operating characteristic curve, we calculated the area under the curve (AUC) and the best diagnostic threshold (sensitivity and specificity) for predicting severe PPH.</p><p><strong>Results: </strong>Overall, 129 patients were included, 26 (20.2%) with severe PPH. Median SI was significantly higher at T2 in the severe PPH group (1.14 (1.10-1.25) versus 1.0 (0.85-1.10), P<0.001), but not at other times of management. An SI value of ≥1.17 was the best threshold with an AUC of 0.81 (95% CI 0.72 to 0.90), a sensitivity of 0.42 and a specificity of 0.88.</p><p><strong>Conclusions: </strong>SI may be an early indicator of severe PPH during C-section under SA.</p>","PeriodicalId":18522,"journal":{"name":"Minerva anestesiologica","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-02-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva anestesiologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0375-9393.24.18468-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: An early diagnosis of a postpartum hemorrhage (PPH) can be challenging. The Shock Index (SI), the ratio of heart rate to systolic blood pressure, appears to be a useful indicator for the early diagnosis of severe PPH after vaginal delivery. Our primary aim was to evaluate if the SI has a predictive value for severe PPH following cesarean section (C-section) under spinal anesthesia (SA) and its best predictive threshold.
Methods: Retrospective single-center trial including women scheduled for C-section under SA with prevention of maternal hypotension by phenylephrine, and complicated by PPH between 2019 and 2021. Women were divided into two groups: non-severe PPH (blood loss <1000 mL) versus severe PPH (blood loss ≥1000 mL). SI was calculated and compared between the groups at four different time points: T0: prior to C-section; T1: at incision; T2: 15 minutes from start of PPH; T3: end of PPH management. Using receiver operating characteristic curve, we calculated the area under the curve (AUC) and the best diagnostic threshold (sensitivity and specificity) for predicting severe PPH.
Results: Overall, 129 patients were included, 26 (20.2%) with severe PPH. Median SI was significantly higher at T2 in the severe PPH group (1.14 (1.10-1.25) versus 1.0 (0.85-1.10), P<0.001), but not at other times of management. An SI value of ≥1.17 was the best threshold with an AUC of 0.81 (95% CI 0.72 to 0.90), a sensitivity of 0.42 and a specificity of 0.88.
Conclusions: SI may be an early indicator of severe PPH during C-section under SA.
期刊介绍:
Minerva Anestesiologica is the journal of the Italian National Society of Anaesthesia, Analgesia, Resuscitation, and Intensive Care. Minerva Anestesiologica publishes scientific papers on Anesthesiology, Intensive care, Analgesia, Perioperative Medicine and related fields.
Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors.