Does Real-time Feedback Guide Devices Improve the Quality of Chest Compressions in the Bystander (Naves) Provider?

IF 1.2 Q3 EMERGENCY MEDICINE
Journal of Emergencies, Trauma, and Shock Pub Date : 2024-10-01 Epub Date: 2024-11-05 DOI:10.4103/jets.jets_35_24
Thamir AlSayed, Samer Al Haliq, Faisal Katbi, Mohannad Alghamdi, Mohammed Almulhim
{"title":"Does Real-time Feedback Guide Devices Improve the Quality of Chest Compressions in the Bystander (Naves) Provider?","authors":"Thamir AlSayed, Samer Al Haliq, Faisal Katbi, Mohannad Alghamdi, Mohammed Almulhim","doi":"10.4103/jets.jets_35_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Cardiopulmonary resuscitation (CPR) is an important lifesaving technique that must taught to everyone. As most cardiac arrests occur outside of the hospital, training the general population in the recognition of cardiac arrest and performing high-quality CPR is vital. Thus, this study aimed to compare the chest compression quality data (rate, depth, and fraction) with and without the use of feedback devices during CPR.</p><p><strong>Methods: </strong>A crossover observational study was carried out at a tertiary hospital in September 2021. Five hundred and seventeen 1<sup>st</sup>-year university students were recruited, and the response rate was 90% (465). A feedback device was used to collect data. The data were numerically coded and statistical software (SPSS 21) was used to perform descriptive and inferential statistical analysis, including a paired <i>t</i>-test.</p><p><strong>Results: </strong>The mean compression rate with feedback was statistically significantly lower after performing one cycle of CPR (mean difference: -5.610; 95% confidence interval [CI]= -7.987--3.233; <i>P</i> < 0.001), the difference between mean compression depth with and without feedback was not statistically significant (mean difference: = -0.006; 95% CI = -0.190-0.177; <i>P</i> = 0.944), and the mean compression target (%) with feedback was statistically significantly higher (mean difference: -15.951; 95% CI = -17.894--14.009; <i>P</i> < 0.001).</p><p><strong>Conclusions: </strong>We found that the use of feedback devices during layperson-simulated CPR scenarios significantly improved the quality of chest compression in terms of depth and rate and resulted in more guidelines adherence. Moreover, national programs for CPR education should be implemented.</p>","PeriodicalId":15692,"journal":{"name":"Journal of Emergencies, Trauma, and Shock","volume":"17 4","pages":"221-224"},"PeriodicalIF":1.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11792752/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Emergencies, Trauma, and Shock","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jets.jets_35_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Cardiopulmonary resuscitation (CPR) is an important lifesaving technique that must taught to everyone. As most cardiac arrests occur outside of the hospital, training the general population in the recognition of cardiac arrest and performing high-quality CPR is vital. Thus, this study aimed to compare the chest compression quality data (rate, depth, and fraction) with and without the use of feedback devices during CPR.

Methods: A crossover observational study was carried out at a tertiary hospital in September 2021. Five hundred and seventeen 1st-year university students were recruited, and the response rate was 90% (465). A feedback device was used to collect data. The data were numerically coded and statistical software (SPSS 21) was used to perform descriptive and inferential statistical analysis, including a paired t-test.

Results: The mean compression rate with feedback was statistically significantly lower after performing one cycle of CPR (mean difference: -5.610; 95% confidence interval [CI]= -7.987--3.233; P < 0.001), the difference between mean compression depth with and without feedback was not statistically significant (mean difference: = -0.006; 95% CI = -0.190-0.177; P = 0.944), and the mean compression target (%) with feedback was statistically significantly higher (mean difference: -15.951; 95% CI = -17.894--14.009; P < 0.001).

Conclusions: We found that the use of feedback devices during layperson-simulated CPR scenarios significantly improved the quality of chest compression in terms of depth and rate and resulted in more guidelines adherence. Moreover, national programs for CPR education should be implemented.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.90
自引率
7.10%
发文量
52
审稿时长
39 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信