Attack-data independent defence mechanism against adversarial attacks on ECG signal

IF 4.4 2区 计算机科学 Q1 COMPUTER SCIENCE, HARDWARE & ARCHITECTURE
Saifur Rahman, Shantanu Pal, Ahsan Habib, Lei Pan, Chandan Karmakar
{"title":"Attack-data independent defence mechanism against adversarial attacks on ECG signal","authors":"Saifur Rahman,&nbsp;Shantanu Pal,&nbsp;Ahsan Habib,&nbsp;Lei Pan,&nbsp;Chandan Karmakar","doi":"10.1016/j.comnet.2024.111027","DOIUrl":null,"url":null,"abstract":"<div><div>Adversarial attacks pose a significant threat to the integrity and reliability of electrocardiogram (ECG) signals, compromising their use in critical applications, e.g., arrhythmia detection and classification. In this paper, we propose an attack-data-independent defence mechanism to effectively mitigate adversarial attacks on ECG signals. Unlike existing defence mechanisms that rely on learning from adversarial samples, our proposed approach operates as a ‘gatekeeper,’ selectively discarding noisy and attack signals while allowing only clean and non-attack ECG signals to be stored in the data layer. This ensures the availability of reliable and high-quality ECG data for subsequent analysis. The proposed defence mechanism not only detects and filters out the attack and noisy ECG signals but also provides robust protection against adversarial attacks, enhancing the integrity and trustworthiness of ECG data for critical applications. To evaluate the effectiveness of our proposal, we conduct experiments using physiologic and synthetic ECG datasets against two well-known attacks: a white-box attack (Fast Gradient Signed Method (FGSM) and Projected Gradient Descent (PGD)) and a black-box attack (HopSkipJump and Boundary). Our experimental results demonstrate the superiority and effectiveness of our approach in defending against adversarial attacks on ECG signals, making it a promising solution for ensuring the security and reliability of ECG-based diagnosis in smart healthcare applications.</div></div>","PeriodicalId":50637,"journal":{"name":"Computer Networks","volume":"258 ","pages":"Article 111027"},"PeriodicalIF":4.4000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Networks","FirstCategoryId":"94","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1389128624008594","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE","Score":null,"Total":0}
引用次数: 0

Abstract

Adversarial attacks pose a significant threat to the integrity and reliability of electrocardiogram (ECG) signals, compromising their use in critical applications, e.g., arrhythmia detection and classification. In this paper, we propose an attack-data-independent defence mechanism to effectively mitigate adversarial attacks on ECG signals. Unlike existing defence mechanisms that rely on learning from adversarial samples, our proposed approach operates as a ‘gatekeeper,’ selectively discarding noisy and attack signals while allowing only clean and non-attack ECG signals to be stored in the data layer. This ensures the availability of reliable and high-quality ECG data for subsequent analysis. The proposed defence mechanism not only detects and filters out the attack and noisy ECG signals but also provides robust protection against adversarial attacks, enhancing the integrity and trustworthiness of ECG data for critical applications. To evaluate the effectiveness of our proposal, we conduct experiments using physiologic and synthetic ECG datasets against two well-known attacks: a white-box attack (Fast Gradient Signed Method (FGSM) and Projected Gradient Descent (PGD)) and a black-box attack (HopSkipJump and Boundary). Our experimental results demonstrate the superiority and effectiveness of our approach in defending against adversarial attacks on ECG signals, making it a promising solution for ensuring the security and reliability of ECG-based diagnosis in smart healthcare applications.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Computer Networks
Computer Networks 工程技术-电信学
CiteScore
10.80
自引率
3.60%
发文量
434
审稿时长
8.6 months
期刊介绍: Computer Networks is an international, archival journal providing a publication vehicle for complete coverage of all topics of interest to those involved in the computer communications networking area. The audience includes researchers, managers and operators of networks as well as designers and implementors. The Editorial Board will consider any material for publication that is of interest to those groups.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信