{"title":"Delineation of the brachial plexus by contrast-enhanced photon-counting detector CT and virtual monoenergetic images","authors":"Masahiro Nakashima, Tatsuya Kawai, Kazuhisa Matsumoto, Takatsune Kawaguchi, Nobuo Kitera, Seita Watanabe, Toshihide Itoh, Akio Hiwatashi","doi":"10.1016/j.ejrad.2025.111964","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>To improve the image quality of the brachial plexus in photon-counting detector CT (PCD-CT) using contrast media and virtual monoenergetic images (VMI).</div></div><div><h3>Materials & Methods</h3><div>We retrospectively analyzed contrast-enhanced neck PCD-CT images scanned in March-July 2023. Unenhanced and contrast-enhanced images were compared, and then 40-, 70-, and 100-keV VMIs were compared. The qualitative evaluation used a five-point Likert scale regarding overall image quality (IQ), sharpness, and noise. The quantitative evaluation used the standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Freidman’s test and one-way ANOVA were performed.</div></div><div><h3>Results</h3><div>Forty patients (65 years ± 17, 21 males) were included. The median scores [interquartile range, IQR] for the unenhanced and contrast-enhanced groups were IQ, 3 [2,3] and 4 [3,4] (P < 0.001); sharpness, 3 [2,3] and 4 [3,4] (P < 0.001); and noise, 3 [3,4] and 3 [3,4] (P = 0.63). Mean ± SD scores were SD, 6.7 ± 1.4 and 6.7 ± 1.0 (P = 0.95); SNR, 5.1 ± 1.2 and 5.4 ± 1.4 (P = 0.04); and CNR, 4.8 ± 1.5 and 8.1 ± 2.3 (P < 0.001). The 40-, 70-, and 100-keV groups’ IQ were 2 [2,3], 4 [3,4], and 3 [3,4]; their sharpness scores were 2 [2,3], 3 [3,4], and 3 [2,3] (all, P < 0.05). Those for noise were 2 [1–3], 3 [3,4], and 4 [3,4] (all, P < 0.001 except for 70-keV vs.100-keV: P = 0.16). The SDs were 13.1 ± 2.5, 7.5 ± 1.2, and 6.0 ± 1.1. The SNRs were 4.2 ± 1.9, 5.0 ± 1.2, and 5.7 ± 1.5 (all, P < 0.001). The CNRs were 8.7 ± 4.0, 6.8 ± 2.3, and 6.5 ± 2.3 (all, P < 0.001 except for 70-keV vs.100-keV: P = 0.51).</div></div><div><h3>Conclusion</h3><div>Contrast-enhanced PCD-CT and VMIs provided good delineation of the brachial plexus.</div></div>","PeriodicalId":12063,"journal":{"name":"European Journal of Radiology","volume":"184 ","pages":"Article 111964"},"PeriodicalIF":3.3000,"publicationDate":"2025-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0720048X25000506","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
To improve the image quality of the brachial plexus in photon-counting detector CT (PCD-CT) using contrast media and virtual monoenergetic images (VMI).
Materials & Methods
We retrospectively analyzed contrast-enhanced neck PCD-CT images scanned in March-July 2023. Unenhanced and contrast-enhanced images were compared, and then 40-, 70-, and 100-keV VMIs were compared. The qualitative evaluation used a five-point Likert scale regarding overall image quality (IQ), sharpness, and noise. The quantitative evaluation used the standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Freidman’s test and one-way ANOVA were performed.
Results
Forty patients (65 years ± 17, 21 males) were included. The median scores [interquartile range, IQR] for the unenhanced and contrast-enhanced groups were IQ, 3 [2,3] and 4 [3,4] (P < 0.001); sharpness, 3 [2,3] and 4 [3,4] (P < 0.001); and noise, 3 [3,4] and 3 [3,4] (P = 0.63). Mean ± SD scores were SD, 6.7 ± 1.4 and 6.7 ± 1.0 (P = 0.95); SNR, 5.1 ± 1.2 and 5.4 ± 1.4 (P = 0.04); and CNR, 4.8 ± 1.5 and 8.1 ± 2.3 (P < 0.001). The 40-, 70-, and 100-keV groups’ IQ were 2 [2,3], 4 [3,4], and 3 [3,4]; their sharpness scores were 2 [2,3], 3 [3,4], and 3 [2,3] (all, P < 0.05). Those for noise were 2 [1–3], 3 [3,4], and 4 [3,4] (all, P < 0.001 except for 70-keV vs.100-keV: P = 0.16). The SDs were 13.1 ± 2.5, 7.5 ± 1.2, and 6.0 ± 1.1. The SNRs were 4.2 ± 1.9, 5.0 ± 1.2, and 5.7 ± 1.5 (all, P < 0.001). The CNRs were 8.7 ± 4.0, 6.8 ± 2.3, and 6.5 ± 2.3 (all, P < 0.001 except for 70-keV vs.100-keV: P = 0.51).
Conclusion
Contrast-enhanced PCD-CT and VMIs provided good delineation of the brachial plexus.
期刊介绍:
European Journal of Radiology is an international journal which aims to communicate to its readers, state-of-the-art information on imaging developments in the form of high quality original research articles and timely reviews on current developments in the field.
Its audience includes clinicians at all levels of training including radiology trainees, newly qualified imaging specialists and the experienced radiologist. Its aim is to inform efficient, appropriate and evidence-based imaging practice to the benefit of patients worldwide.