A calibration approach for compensating hysteresis and nonlinearity error in an MEMS based instrument for porewater pressure monitoring

IF 1.4 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Milad Barzegar, Saba Gharehdash, Wendy Timms
{"title":"A calibration approach for compensating hysteresis and nonlinearity error in an MEMS based instrument for porewater pressure monitoring","authors":"Milad Barzegar,&nbsp;Saba Gharehdash,&nbsp;Wendy Timms","doi":"10.1049/smt2.12234","DOIUrl":null,"url":null,"abstract":"<p>Micro-electro-mechanical system (MEMS) technology is becoming increasingly popular in geotechnical and hydrological monitoring due to their distinct features, including its small size, low cost, low energy consumption, and resistance to vibration shock. Due to the nature of design, they exhibit a series of errors, and most importantly, hysteresis and nonlinearity, which should be compensated before any practical application in order to achieve the highest degree of accuracy and precision. This article proposes a practical approach to enhance the accuracy of a newly developed MEMS instrument for groundwater monitoring. The hysteresis and nonlinearity errors were compensated using an integrated two-step approach with an optimized Preisach model and an optimized spline approximation, respectively. A hybrid differential evolution-hill climbing algorithm was utilized to achieve optimum models. This optimization algorithm integrates global and local search, offering higher accuracy and computational stability with a lower calibration point requirement. Analysing the results indicates that the nonlinearity error shows an improvement of more than 94% and hysteresis decreased up to 67%. The results illustrate that the compensation can be performed very well using the proposed methodology with lower uncertainty, mean square error, and standard deviation compared to non-optimized models.</p>","PeriodicalId":54999,"journal":{"name":"Iet Science Measurement & Technology","volume":"19 1","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/smt2.12234","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Science Measurement & Technology","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/smt2.12234","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Micro-electro-mechanical system (MEMS) technology is becoming increasingly popular in geotechnical and hydrological monitoring due to their distinct features, including its small size, low cost, low energy consumption, and resistance to vibration shock. Due to the nature of design, they exhibit a series of errors, and most importantly, hysteresis and nonlinearity, which should be compensated before any practical application in order to achieve the highest degree of accuracy and precision. This article proposes a practical approach to enhance the accuracy of a newly developed MEMS instrument for groundwater monitoring. The hysteresis and nonlinearity errors were compensated using an integrated two-step approach with an optimized Preisach model and an optimized spline approximation, respectively. A hybrid differential evolution-hill climbing algorithm was utilized to achieve optimum models. This optimization algorithm integrates global and local search, offering higher accuracy and computational stability with a lower calibration point requirement. Analysing the results indicates that the nonlinearity error shows an improvement of more than 94% and hysteresis decreased up to 67%. The results illustrate that the compensation can be performed very well using the proposed methodology with lower uncertainty, mean square error, and standard deviation compared to non-optimized models.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Iet Science Measurement & Technology
Iet Science Measurement & Technology 工程技术-工程:电子与电气
CiteScore
4.30
自引率
7.10%
发文量
41
审稿时长
7.5 months
期刊介绍: IET Science, Measurement & Technology publishes papers in science, engineering and technology underpinning electronic and electrical engineering, nanotechnology and medical instrumentation.The emphasis of the journal is on theory, simulation methodologies and measurement techniques. The major themes of the journal are: - electromagnetism including electromagnetic theory, computational electromagnetics and EMC - properties and applications of dielectric, magnetic, magneto-optic, piezoelectric materials down to the nanometre scale - measurement and instrumentation including sensors, actuators, medical instrumentation, fundamentals of measurement including measurement standards, uncertainty, dissemination and calibration Applications are welcome for illustrative purposes but the novelty and originality should focus on the proposed new methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信