Shortening the Analysis Time of a “Ready-To-Use” Relative Response Factor Database-Coupled Pyrolyzer/Thermal Desorption–Gas Chromatography–Mass Spectrometry Method of Screening for Phthalate Esters, Polybrominated Diphenyl Ethers, and Polybrominated Biphenyls in Polymers

IF 1.2 4区 化学 Q4 BIOCHEMICAL RESEARCH METHODS
Yukihiko Kudo, Tomohiro Uchimura
{"title":"Shortening the Analysis Time of a “Ready-To-Use” Relative Response Factor Database-Coupled Pyrolyzer/Thermal Desorption–Gas Chromatography–Mass Spectrometry Method of Screening for Phthalate Esters, Polybrominated Diphenyl Ethers, and Polybrominated Biphenyls in Polymers","authors":"Yukihiko Kudo,&nbsp;Tomohiro Uchimura","doi":"10.1007/s10337-024-04371-7","DOIUrl":null,"url":null,"abstract":"<div><p>The European Union RoHS Directive restricts the presence of phthalate esters, polybrominated diphenyl ethers (PBDEs), and polybrominated biphenyls (PBBs) in electrotechnical products. The international standard IEC 62321-3-3 describes a method of screening for these chemicals using gas chromatography–mass spectrometry with a pyrolyzer/thermal desorption accessory (Py/TD-GC/MS). Although the IEC 62321-3-3 method is effective at determining levels of these restricted compounds in polymers, applying this method in RoHS testing poses two issues: it requires the preparation of a relative response factor (RRF) database from expensive standard mixed solutions, and it has a long analysis time (30 min). In a previous report, we described a method based on a “ready-to-use” RRF database that eliminates preparation of the RRF database. In this report, we resolved the remaining issue by improving the analytical throughput of the IEC 62321-3-3 method. By optimizing the Py/TD and GC/MS conditions, we almost halved the analysis time to 16 min while maintaining analytical accuracy. These optimized conditions were then combined with the above-mentioned “ready-to-use” RRF database to create a new method that resolves both of the issues with the IEC 62321-3-3 method. This new method demonstrated good sensitivity with a lower limit of detection of under 30 mg/kg for each target compound. We also assessed the analytical accuracy of this new method by analyzing various standard polymer materials on two different analytical instruments. On both instruments, the mean recovery rate was within 100 ± 30% for seven phthalate esters and for combined concentrations of PBDE and PBB congeners, which demonstrated that the quantitative accuracy of the new method is sufficient for RoHS testing. The new method resolves the issues with the IEC 62321-3-3 method and offers rapid, simple, and reliable screening that can be adopted for RoHS testing.</p></div>","PeriodicalId":518,"journal":{"name":"Chromatographia","volume":"88 1","pages":"81 - 92"},"PeriodicalIF":1.2000,"publicationDate":"2024-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10337-024-04371-7.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatographia","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s10337-024-04371-7","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

The European Union RoHS Directive restricts the presence of phthalate esters, polybrominated diphenyl ethers (PBDEs), and polybrominated biphenyls (PBBs) in electrotechnical products. The international standard IEC 62321-3-3 describes a method of screening for these chemicals using gas chromatography–mass spectrometry with a pyrolyzer/thermal desorption accessory (Py/TD-GC/MS). Although the IEC 62321-3-3 method is effective at determining levels of these restricted compounds in polymers, applying this method in RoHS testing poses two issues: it requires the preparation of a relative response factor (RRF) database from expensive standard mixed solutions, and it has a long analysis time (30 min). In a previous report, we described a method based on a “ready-to-use” RRF database that eliminates preparation of the RRF database. In this report, we resolved the remaining issue by improving the analytical throughput of the IEC 62321-3-3 method. By optimizing the Py/TD and GC/MS conditions, we almost halved the analysis time to 16 min while maintaining analytical accuracy. These optimized conditions were then combined with the above-mentioned “ready-to-use” RRF database to create a new method that resolves both of the issues with the IEC 62321-3-3 method. This new method demonstrated good sensitivity with a lower limit of detection of under 30 mg/kg for each target compound. We also assessed the analytical accuracy of this new method by analyzing various standard polymer materials on two different analytical instruments. On both instruments, the mean recovery rate was within 100 ± 30% for seven phthalate esters and for combined concentrations of PBDE and PBB congeners, which demonstrated that the quantitative accuracy of the new method is sufficient for RoHS testing. The new method resolves the issues with the IEC 62321-3-3 method and offers rapid, simple, and reliable screening that can be adopted for RoHS testing.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Chromatographia
Chromatographia 化学-分析化学
CiteScore
3.40
自引率
5.90%
发文量
103
审稿时长
2.2 months
期刊介绍: Separation sciences, in all their various forms such as chromatography, field-flow fractionation, and electrophoresis, provide some of the most powerful techniques in analytical chemistry and are applied within a number of important application areas, including archaeology, biotechnology, clinical, environmental, food, medical, petroleum, pharmaceutical, polymer and biopolymer research. Beyond serving analytical purposes, separation techniques are also used for preparative and process-scale applications. The scope and power of separation sciences is significantly extended by combination with spectroscopic detection methods (e.g., laser-based approaches, nuclear-magnetic resonance, Raman, chemiluminescence) and particularly, mass spectrometry, to create hyphenated techniques. In addition to exciting new developments in chromatography, such as ultra high-pressure systems, multidimensional separations, and high-temperature approaches, there have also been great advances in hybrid methods combining chromatography and electro-based separations, especially on the micro- and nanoscale. Integrated biological procedures (e.g., enzymatic, immunological, receptor-based assays) can also be part of the overall analytical process.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信