Energy conservation and techno-environmental analysis in natural gas liquefaction with single and dual-mixed refrigerants: A comparison

Edose Osagie , Joseph Akpan , Wilson Ekpotu , Gabriel Umoh , Joseph Akintola , Queen Moses , Philemon Udom
{"title":"Energy conservation and techno-environmental analysis in natural gas liquefaction with single and dual-mixed refrigerants: A comparison","authors":"Edose Osagie ,&nbsp;Joseph Akpan ,&nbsp;Wilson Ekpotu ,&nbsp;Gabriel Umoh ,&nbsp;Joseph Akintola ,&nbsp;Queen Moses ,&nbsp;Philemon Udom","doi":"10.1016/j.fraope.2024.100196","DOIUrl":null,"url":null,"abstract":"<div><div>The need to meet energy demand and produce cleaner energy has propped up the drive to explore natural gas options and, more recently, liquefied natural gas. The thermal efficiency of a liquefaction process is very important when considering the energy requirement. The liquefaction technology by the refrigerant is one of the most common technologies becoming popular among researchers for its flexible features. This study compares the energy performance of the dual mixed refrigerant (PRICO DMR) and single mixed refrigerant (PRICO SMR) propane pre-cool liquefaction technology using a process simulator by carrying out sensitivity analysis on the process parameters to see its impact on the refrigerant flow rate, power consumption, and the specific power. The Honeywell UNISIM R451, software process simulator, was used to simulate the PRICO SMR and DMR processes with natural gas supplied at 55 °C, 61 bar, and 150 MMSCFD as the base condition. From the simulation, the ‘UA’ for the Heat Exchangers used with mixed refrigerant, the SMR was 36470 kW/°C, and the DMR was 5172 and 4612 kW/°C. The result shows that at the base condition, the refrigerant flow rate, power consumption, and specific power for the DMR and SMR was 404.9 MMSCFD, 96.8 MW, 0.409 kWhr/kg-LNG, and 507 MMSCFD, 144.5 MW, and 1.261 kWhr/kg-LNG, respectively. With sensitivity analysis, the simulation results showed that for both the SMR and DMR processes at any temperature, increasing pressure increases the refrigerant flow rate and power consumption but decreases the specific power. In addition, the DMR provided a potential CO<sub>2</sub> emissions potentials saving by an average factor of 2.953 and a better savings in energy demand with the specific power reaching 67.7 % and refrigerant consumption than the SMR process.</div></div>","PeriodicalId":100554,"journal":{"name":"Franklin Open","volume":"10 ","pages":"Article 100196"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Franklin Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773186324001269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The need to meet energy demand and produce cleaner energy has propped up the drive to explore natural gas options and, more recently, liquefied natural gas. The thermal efficiency of a liquefaction process is very important when considering the energy requirement. The liquefaction technology by the refrigerant is one of the most common technologies becoming popular among researchers for its flexible features. This study compares the energy performance of the dual mixed refrigerant (PRICO DMR) and single mixed refrigerant (PRICO SMR) propane pre-cool liquefaction technology using a process simulator by carrying out sensitivity analysis on the process parameters to see its impact on the refrigerant flow rate, power consumption, and the specific power. The Honeywell UNISIM R451, software process simulator, was used to simulate the PRICO SMR and DMR processes with natural gas supplied at 55 °C, 61 bar, and 150 MMSCFD as the base condition. From the simulation, the ‘UA’ for the Heat Exchangers used with mixed refrigerant, the SMR was 36470 kW/°C, and the DMR was 5172 and 4612 kW/°C. The result shows that at the base condition, the refrigerant flow rate, power consumption, and specific power for the DMR and SMR was 404.9 MMSCFD, 96.8 MW, 0.409 kWhr/kg-LNG, and 507 MMSCFD, 144.5 MW, and 1.261 kWhr/kg-LNG, respectively. With sensitivity analysis, the simulation results showed that for both the SMR and DMR processes at any temperature, increasing pressure increases the refrigerant flow rate and power consumption but decreases the specific power. In addition, the DMR provided a potential CO2 emissions potentials saving by an average factor of 2.953 and a better savings in energy demand with the specific power reaching 67.7 % and refrigerant consumption than the SMR process.
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信