Jiayang Shi , Louisa Brown , Amir R. Zekavat , Daniël M. Pelt , Charlotte K. Hagen
{"title":"Self-supervised resolution enhancement for anisotropic volumes in edge illumination X-ray phase contrast micro-computed tomography","authors":"Jiayang Shi , Louisa Brown , Amir R. Zekavat , Daniël M. Pelt , Charlotte K. Hagen","doi":"10.1016/j.tmater.2024.100046","DOIUrl":null,"url":null,"abstract":"<div><div>X-ray phase contrast micro-computed tomography (micro-CT) can achieve higher contrast than conventional absorption-based X-ray micro-CT by utilizing refraction in addition to attenuation. In this work, we focus on a specific X-ray phase contrast technique, edge illumination (EI) micro-CT. EI uses a sample mask with transmitting apertures that split the X-ray beam into narrow beamlets, enabling detection of refraction-included intensity variations. Between the typical mask designs (circular and slit-shaped apertures), slit-shaped apertures offer practical advantages over circular ones, as they only require sample stepping in one direction, thereby reducing scanning time. However, this leads to anisotropic resolution, as the slit-shaped apertures enhances resolution only along the direction orthogonal to the slits. To address this limitation, we propose a self-supervised method that trains on high-resolution in-plane images to enhance resolution for out-of-plane images, effectively mitigating anisotropy. Our results on both simulated and real EI micro-CT datasets demonstrate the effectiveness of the proposed method.</div></div>","PeriodicalId":101254,"journal":{"name":"Tomography of Materials and Structures","volume":"7 ","pages":"Article 100046"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tomography of Materials and Structures","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949673X24000238","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
X-ray phase contrast micro-computed tomography (micro-CT) can achieve higher contrast than conventional absorption-based X-ray micro-CT by utilizing refraction in addition to attenuation. In this work, we focus on a specific X-ray phase contrast technique, edge illumination (EI) micro-CT. EI uses a sample mask with transmitting apertures that split the X-ray beam into narrow beamlets, enabling detection of refraction-included intensity variations. Between the typical mask designs (circular and slit-shaped apertures), slit-shaped apertures offer practical advantages over circular ones, as they only require sample stepping in one direction, thereby reducing scanning time. However, this leads to anisotropic resolution, as the slit-shaped apertures enhances resolution only along the direction orthogonal to the slits. To address this limitation, we propose a self-supervised method that trains on high-resolution in-plane images to enhance resolution for out-of-plane images, effectively mitigating anisotropy. Our results on both simulated and real EI micro-CT datasets demonstrate the effectiveness of the proposed method.