Novel Robotic Valvuloplastic Esophagogastrostomy Technique After Proximal Gastrectomy: A Safety and Feasibility Study.

IF 1.1 4区 医学 Q3 SURGERY
Neda Amini, Takahiro Kinoshita, Manuel Arrieta, Mitsumasa Yoshida, Hiromi Nagata, Takumi Habu, Masaru Komatsu, Masahiro Yura
{"title":"Novel Robotic Valvuloplastic Esophagogastrostomy Technique After Proximal Gastrectomy: A Safety and Feasibility Study.","authors":"Neda Amini, Takahiro Kinoshita, Manuel Arrieta, Mitsumasa Yoshida, Hiromi Nagata, Takumi Habu, Masaru Komatsu, Masahiro Yura","doi":"10.1097/SLE.0000000000001322","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Esophagogastrostomy is one of the reconstruction techniques after proximal gastrectomy, but reflux and esophagitis are significant concerns. We introduced a new robotic valvuloplasty technique (single-flap), taking advantage of robotic surgery to address these issues and simplify the technique, especially for tumors with esophageal invasion.</p><p><strong>Methods: </strong>Between March 2022 and March 2024, patients who underwent robotic proximal gastrectomy with the single-flap technique were included. Based on the difficulty of the surgery, patients were divided into 2 groups: one with esophageal invasion requiring anastomosis in the mediastinum and the second group with tumors in the upper third of the stomach requiring anastomosis in the abdomen.</p><p><strong>Results: </strong>A total of 22 patients were included: 13 in the esophageal invasion group and 9 in the upper stomach group. The median size of esophageal invasion was 2 cm (1 to 3 cm). The median operative time was 320 minutes (esophageal invasion 326 vs. upper stomach 280 min, P=0.51), with a median blood loss of 35 g (31 vs. 38 g, P=0.19). No postoperative mortality, anastomotic leaks, reflux symptoms, or pancreatic fistulas were observed. Eighteen patients underwent endoscopic evaluation, and no sign of esophagitis was detected. Five patients (22.7%) developed grade III strictures requiring endoscopic balloon dilation (esophageal invasion 32.1% vs. upper stomach 22.2%; P=0.96).</p><p><strong>Conclusions: </strong>Robotic proximal gastrectomy with single-flap valvuloplastic esophagogastrostomy is a safe and feasible option for gastroesophageal junction tumors with up to 3 cm of esophageal invasion.</p>","PeriodicalId":22092,"journal":{"name":"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Laparoscopy, Endoscopy & Percutaneous Techniques","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/SLE.0000000000001322","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Esophagogastrostomy is one of the reconstruction techniques after proximal gastrectomy, but reflux and esophagitis are significant concerns. We introduced a new robotic valvuloplasty technique (single-flap), taking advantage of robotic surgery to address these issues and simplify the technique, especially for tumors with esophageal invasion.

Methods: Between March 2022 and March 2024, patients who underwent robotic proximal gastrectomy with the single-flap technique were included. Based on the difficulty of the surgery, patients were divided into 2 groups: one with esophageal invasion requiring anastomosis in the mediastinum and the second group with tumors in the upper third of the stomach requiring anastomosis in the abdomen.

Results: A total of 22 patients were included: 13 in the esophageal invasion group and 9 in the upper stomach group. The median size of esophageal invasion was 2 cm (1 to 3 cm). The median operative time was 320 minutes (esophageal invasion 326 vs. upper stomach 280 min, P=0.51), with a median blood loss of 35 g (31 vs. 38 g, P=0.19). No postoperative mortality, anastomotic leaks, reflux symptoms, or pancreatic fistulas were observed. Eighteen patients underwent endoscopic evaluation, and no sign of esophagitis was detected. Five patients (22.7%) developed grade III strictures requiring endoscopic balloon dilation (esophageal invasion 32.1% vs. upper stomach 22.2%; P=0.96).

Conclusions: Robotic proximal gastrectomy with single-flap valvuloplastic esophagogastrostomy is a safe and feasible option for gastroesophageal junction tumors with up to 3 cm of esophageal invasion.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.00
自引率
10.00%
发文量
103
审稿时长
3-8 weeks
期刊介绍: Surgical Laparoscopy Endoscopy & Percutaneous Techniques is a primary source for peer-reviewed, original articles on the newest techniques and applications in operative laparoscopy and endoscopy. Its Editorial Board includes many of the surgeons who pioneered the use of these revolutionary techniques. The journal provides complete, timely, accurate, practical coverage of laparoscopic and endoscopic techniques and procedures; current clinical and basic science research; preoperative and postoperative patient management; complications in laparoscopic and endoscopic surgery; and new developments in instrumentation and technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信