Consistency between metagenomic next-generation sequencing versus traditional microbiological tests for infective disease: systemic review and meta-analysis

IF 8.8 1区 医学 Q1 CRITICAL CARE MEDICINE
Chengxi Liu, Xiao Song, Jihai Liu, Liang Zong, Tao Xu, Xu Han, Fan Li, Bo Li, Huadong Zhu, Di Shi
{"title":"Consistency between metagenomic next-generation sequencing versus traditional microbiological tests for infective disease: systemic review and meta-analysis","authors":"Chengxi Liu, Xiao Song, Jihai Liu, Liang Zong, Tao Xu, Xu Han, Fan Li, Bo Li, Huadong Zhu, Di Shi","doi":"10.1186/s13054-025-05288-9","DOIUrl":null,"url":null,"abstract":"Pathogen identification is essential in sepsis and septic shock. Metagenomic next-generation sequencing (mNGS) is a novel pathogen detection method with several advantages over traditional tests. However, the consistency between mNGS and traditional pathogen tests requires further investigation. We aimed to assess the consistency between mNGS and traditional pathogen tests and to identify the factors influencing this consistency. This systematic review and meta-analysis involved a comprehensive search of mNGS and traditional pathogen tests in PubMed, Embase, Scopus, Web of Science, and the Cochrane Library. Data from included studies were extracted, and kappa consistency between mNGS and traditional tests was calculated. Study quality was evaluated using the QUADAS-2 tool. The search identified 415 studies, of which 27 were included in the analysis, involving 4112 individuals. Meta-analysis showed a pooled consistency of 0.319 ± 0.013 (p < 0.001), indicating a moderate relationship. In terms of sample type, cerebrospinal fluid showed the highest pooled kappa consistency at 0.500 ± 0.029 (p < 0.001). Immunocompromised patients had a lower pooled kappa consistency of 0.294 ± 0.014 (p < 0.001) compared to 0.321 ± 0.028 (p < 0.001) in immunocompetent patients. Positive percent agreement of mNGS was 83.63% over traditional microbiological test, and negative percent agreement was 54.59%. This review demonstrates a moderate relationship between mNGS and traditional pathogen tests, indicating a complex relationship between these two methods. Sterile samples show higher consistency than non-sterile samples. Immune function deficiency may reduce the consistency between mNGS and traditional tests. Further research is needed on the use of mNGS in sepsis and septic shock.","PeriodicalId":10811,"journal":{"name":"Critical Care","volume":"15 1","pages":""},"PeriodicalIF":8.8000,"publicationDate":"2025-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13054-025-05288-9","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Pathogen identification is essential in sepsis and septic shock. Metagenomic next-generation sequencing (mNGS) is a novel pathogen detection method with several advantages over traditional tests. However, the consistency between mNGS and traditional pathogen tests requires further investigation. We aimed to assess the consistency between mNGS and traditional pathogen tests and to identify the factors influencing this consistency. This systematic review and meta-analysis involved a comprehensive search of mNGS and traditional pathogen tests in PubMed, Embase, Scopus, Web of Science, and the Cochrane Library. Data from included studies were extracted, and kappa consistency between mNGS and traditional tests was calculated. Study quality was evaluated using the QUADAS-2 tool. The search identified 415 studies, of which 27 were included in the analysis, involving 4112 individuals. Meta-analysis showed a pooled consistency of 0.319 ± 0.013 (p < 0.001), indicating a moderate relationship. In terms of sample type, cerebrospinal fluid showed the highest pooled kappa consistency at 0.500 ± 0.029 (p < 0.001). Immunocompromised patients had a lower pooled kappa consistency of 0.294 ± 0.014 (p < 0.001) compared to 0.321 ± 0.028 (p < 0.001) in immunocompetent patients. Positive percent agreement of mNGS was 83.63% over traditional microbiological test, and negative percent agreement was 54.59%. This review demonstrates a moderate relationship between mNGS and traditional pathogen tests, indicating a complex relationship between these two methods. Sterile samples show higher consistency than non-sterile samples. Immune function deficiency may reduce the consistency between mNGS and traditional tests. Further research is needed on the use of mNGS in sepsis and septic shock.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Critical Care
Critical Care 医学-危重病医学
CiteScore
20.60
自引率
3.30%
发文量
348
审稿时长
1.5 months
期刊介绍: Critical Care is an esteemed international medical journal that undergoes a rigorous peer-review process to maintain its high quality standards. Its primary objective is to enhance the healthcare services offered to critically ill patients. To achieve this, the journal focuses on gathering, exchanging, disseminating, and endorsing evidence-based information that is highly relevant to intensivists. By doing so, Critical Care seeks to provide a thorough and inclusive examination of the intensive care field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信