Similar wear rates of 1st and 2nd generation highly cross-linked polyethylene in primary total hip arthroplasty in patients less than 30 years of age: A minimum 5-year follow-up.

IF 2.3 3区 医学 Q2 ORTHOPEDICS
Jung Shin Kim, Min Uk Do, Jung Bum Han, Sang-Min Lee, Nam Hoon Moon, Kuen Tak Suh, Won Chul Shin
{"title":"Similar wear rates of 1st and 2nd generation highly cross-linked polyethylene in primary total hip arthroplasty in patients less than 30 years of age: A minimum 5-year follow-up.","authors":"Jung Shin Kim, Min Uk Do, Jung Bum Han, Sang-Min Lee, Nam Hoon Moon, Kuen Tak Suh, Won Chul Shin","doi":"10.1016/j.otsr.2025.104178","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Younger patients who undergo total hip arthroplasty (THA) often exhibit higher activity and functionality. After the 1 st generation highly cross-linked polyethylene liners (HXLPE), there was advancement with the development of the 2nd generation Vitamin E-infused highly cross-linked polyethylene (VEPE) for polyethylene liners. However, there is limited research comparing these advancements, especially in younger patients. Therefore we did a retrospective comparative study aiming to determine: 1) the wear rate, 2) survivorships of the 1 st and 2nd generations of HXLPE in patients aged <30 years who underwent THA.</p><p><strong>Hypothesis: </strong>There is no difference between first and second generation of highly cross-linked polyethylene regarding lower linear and volumetric wear rates.</p><p><strong>Methods: </strong>From 2008-2019, we selected 121 patients, 150 hips of ceramic-polyethylene articulation THA in patients aged <30 years at least 5 years of follow-up. These patients were divided into two groups: 80 hips for 1 st generation HXLPE and 70 hips for 2nd generation VEPE. Both groups had no significant difference regarding age, gender, BMI, and the indication for THA. We compared the wear rate of polyethylene in both groups using PolyWare 7 software and assessed the 5-year THA survival rate.</p><p><strong>Results: </strong>In both groups, there was no significant difference in linear and volumetric wear, as measured using PolyWare 7 software. Linear wear rate was 0.0365 ± 0.0187 mm/yr in the 1 st generation HXLPE and 0.0351 ± 0.0171 mm/yr in the 2nd generation VEPE groups. Volumetric wear rate was 20.848 ± 11.319 mm<sup>3</sup>/yr in the 1 st generation HXLPE and 18.679 ± 7.933 mm<sup>3</sup>/yr in the 2nd generation VEPE groups. The overall 5-year survival rate post-surgery was 98.7%; no significant difference in the survival rates between the 1 st and 2nd generation groups (98.8 and 98.6% for the 1 st and 2nd generation groups).</p><p><strong>Conclusion: </strong>In young patients, there was no significant difference in the wear rates between the 1 st generation HXLPE and 2nd generation VEPE when using ceramic-polyethylene bearing surfaces. Based on the analysis of complications, survival rates, and functional scores post-surgery, the results of THA using ceramic-any HXLPE articulation were satisfactory in patients aged <30 years.</p><p><strong>Level of evidence: </strong>III; Case-control study.</p>","PeriodicalId":54664,"journal":{"name":"Orthopaedics & Traumatology-Surgery & Research","volume":" ","pages":"104178"},"PeriodicalIF":2.3000,"publicationDate":"2025-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedics & Traumatology-Surgery & Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.otsr.2025.104178","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Younger patients who undergo total hip arthroplasty (THA) often exhibit higher activity and functionality. After the 1 st generation highly cross-linked polyethylene liners (HXLPE), there was advancement with the development of the 2nd generation Vitamin E-infused highly cross-linked polyethylene (VEPE) for polyethylene liners. However, there is limited research comparing these advancements, especially in younger patients. Therefore we did a retrospective comparative study aiming to determine: 1) the wear rate, 2) survivorships of the 1 st and 2nd generations of HXLPE in patients aged <30 years who underwent THA.

Hypothesis: There is no difference between first and second generation of highly cross-linked polyethylene regarding lower linear and volumetric wear rates.

Methods: From 2008-2019, we selected 121 patients, 150 hips of ceramic-polyethylene articulation THA in patients aged <30 years at least 5 years of follow-up. These patients were divided into two groups: 80 hips for 1 st generation HXLPE and 70 hips for 2nd generation VEPE. Both groups had no significant difference regarding age, gender, BMI, and the indication for THA. We compared the wear rate of polyethylene in both groups using PolyWare 7 software and assessed the 5-year THA survival rate.

Results: In both groups, there was no significant difference in linear and volumetric wear, as measured using PolyWare 7 software. Linear wear rate was 0.0365 ± 0.0187 mm/yr in the 1 st generation HXLPE and 0.0351 ± 0.0171 mm/yr in the 2nd generation VEPE groups. Volumetric wear rate was 20.848 ± 11.319 mm3/yr in the 1 st generation HXLPE and 18.679 ± 7.933 mm3/yr in the 2nd generation VEPE groups. The overall 5-year survival rate post-surgery was 98.7%; no significant difference in the survival rates between the 1 st and 2nd generation groups (98.8 and 98.6% for the 1 st and 2nd generation groups).

Conclusion: In young patients, there was no significant difference in the wear rates between the 1 st generation HXLPE and 2nd generation VEPE when using ceramic-polyethylene bearing surfaces. Based on the analysis of complications, survival rates, and functional scores post-surgery, the results of THA using ceramic-any HXLPE articulation were satisfactory in patients aged <30 years.

Level of evidence: III; Case-control study.

求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
26.10%
发文量
329
审稿时长
12.5 weeks
期刊介绍: Orthopaedics & Traumatology: Surgery & Research (OTSR) publishes original scientific work in English related to all domains of orthopaedics. Original articles, Reviews, Technical notes and Concise follow-up of a former OTSR study are published in English in electronic form only and indexed in the main international databases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信