Automated oxygen control for preterm infants receiving continuous positive airway pressure in southwest Nigeria: an open-label, randomised, crossover trial.

IF 19.9 1区 医学 Q1 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH
Rami Subhi, Lachlann McLeod, Adejumoke Idowu Ayede, Iyabode Olabisi Dedeke, Quadri Risikat, Alao Ridwan Akanbi, Adeola Baliqis Fasasi, Ayobami A Bakare, Oluwatosin Helen Adeniyi, Olugbenga Akinrinoye, Olanrewaju Adeigbe, George F Dargaville, Patrick Walker, Anneke C Grobler, Olufunke Mosebolatan, Shiraz Badurdeen, Timothy J Gale, Adegoke G Falade, Peter A Dargaville, Hamish R Graham
{"title":"Automated oxygen control for preterm infants receiving continuous positive airway pressure in southwest Nigeria: an open-label, randomised, crossover trial.","authors":"Rami Subhi, Lachlann McLeod, Adejumoke Idowu Ayede, Iyabode Olabisi Dedeke, Quadri Risikat, Alao Ridwan Akanbi, Adeola Baliqis Fasasi, Ayobami A Bakare, Oluwatosin Helen Adeniyi, Olugbenga Akinrinoye, Olanrewaju Adeigbe, George F Dargaville, Patrick Walker, Anneke C Grobler, Olufunke Mosebolatan, Shiraz Badurdeen, Timothy J Gale, Adegoke G Falade, Peter A Dargaville, Hamish R Graham","doi":"10.1016/S2214-109X(24)00458-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Titration of oxygen therapy to target safe oxygen saturation (SpO<sub>2</sub>) values is a vital part of care for preterm infants, but is difficult to achieve, particularly in settings in which oxygen, monitoring technology, and human resources are scarce. We aimed to evaluate the safety and efficacy of automated titration of oxygen therapy partnered with a low-cost continuous positive airway pressure (CPAP) device versus manual oxygen control in preterm infants requiring CPAP in a high-mortality, low-resource setting.</p><p><strong>Methods: </strong>In this open-label, randomised, crossover trial, preterm infants with a gestational age younger than 34 weeks (or a birthweight <2 kg if gestation was unknown) who were aged 12 h or older and required CPAP and oxygen were recruited at two hospitals in southwest Nigeria. Participants were randomly assigned (1:1) to one of two intervention sequences (ie, to commence the study on automated oxygen control or manual oxygen control) with block randomisation (blocks of 4 and 6) and stratification by health facility. The study statistician was masked to treatment group assignment, but the participants' parents or caregivers and clinical staff were not. Participants received automated or manual oxygen control for two 24-h periods in random sequence. Automated oxygen titration was done with a control algorithm with proven efficacy in high-resource settings. During periods of manual control, oxygen therapy was adjusted by clinicians. The primary outcome was the adjusted mean difference in the proportion of time participants spent in the SpO<sub>2</sub> target range (ie, SpO<sub>2</sub> 91-95% when receiving oxygen or SpO<sub>2</sub> 91-100% when not receiving oxygen) between automated and manual oxygen control, analysed by intention to treat with weighted repeated measures mixed model linear regression. This trial is registered with ClinicalTrials.gov, NCT05508308, and is completed.</p><p><strong>Findings: </strong>Between Sept 13, 2022, and Sept 11, 2023, 72 infants were screened, and 49 (22 female, 27 male; median gestation 29 weeks [IQR 28-31]; median birthweight 1·2 kg [1·1-1·5]) were enrolled in the study and randomly assigned. A total of 80 study periods for 46 infants contributed data to the analysis of the primary outcome as three (6%) of the 49 participants had no oxygenation data from either study period. The mean proportion of time spent in the SpO<sub>2</sub> target range was higher during automated control periods than during periods of manual control (adjusted mean 88·1% [95% CI 84·0-92·2] vs 30·1% [20·9-39·3]; adjusted mean difference 58·0% [95% CI 48·0-67·9]; p<0·0001). There were no device-related adverse patient outcomes and short-term safety outcomes favoured automated control.</p><p><strong>Interpretation: </strong>Automated titration of oxygen partnered with a low-cost CPAP device improved time spent in the safe SpO<sub>2</sub> range compared with manual control. There is high potential for this technology to mitigate the risk of oxygen-mediated complications in preterm infants in low-resource settings.</p><p><strong>Funding: </strong>National Health and Medical Research Council Australia and University of Tasmania.</p>","PeriodicalId":48783,"journal":{"name":"Lancet Global Health","volume":"13 2","pages":"e246-e255"},"PeriodicalIF":19.9000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lancet Global Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/S2214-109X(24)00458-3","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Titration of oxygen therapy to target safe oxygen saturation (SpO2) values is a vital part of care for preterm infants, but is difficult to achieve, particularly in settings in which oxygen, monitoring technology, and human resources are scarce. We aimed to evaluate the safety and efficacy of automated titration of oxygen therapy partnered with a low-cost continuous positive airway pressure (CPAP) device versus manual oxygen control in preterm infants requiring CPAP in a high-mortality, low-resource setting.

Methods: In this open-label, randomised, crossover trial, preterm infants with a gestational age younger than 34 weeks (or a birthweight <2 kg if gestation was unknown) who were aged 12 h or older and required CPAP and oxygen were recruited at two hospitals in southwest Nigeria. Participants were randomly assigned (1:1) to one of two intervention sequences (ie, to commence the study on automated oxygen control or manual oxygen control) with block randomisation (blocks of 4 and 6) and stratification by health facility. The study statistician was masked to treatment group assignment, but the participants' parents or caregivers and clinical staff were not. Participants received automated or manual oxygen control for two 24-h periods in random sequence. Automated oxygen titration was done with a control algorithm with proven efficacy in high-resource settings. During periods of manual control, oxygen therapy was adjusted by clinicians. The primary outcome was the adjusted mean difference in the proportion of time participants spent in the SpO2 target range (ie, SpO2 91-95% when receiving oxygen or SpO2 91-100% when not receiving oxygen) between automated and manual oxygen control, analysed by intention to treat with weighted repeated measures mixed model linear regression. This trial is registered with ClinicalTrials.gov, NCT05508308, and is completed.

Findings: Between Sept 13, 2022, and Sept 11, 2023, 72 infants were screened, and 49 (22 female, 27 male; median gestation 29 weeks [IQR 28-31]; median birthweight 1·2 kg [1·1-1·5]) were enrolled in the study and randomly assigned. A total of 80 study periods for 46 infants contributed data to the analysis of the primary outcome as three (6%) of the 49 participants had no oxygenation data from either study period. The mean proportion of time spent in the SpO2 target range was higher during automated control periods than during periods of manual control (adjusted mean 88·1% [95% CI 84·0-92·2] vs 30·1% [20·9-39·3]; adjusted mean difference 58·0% [95% CI 48·0-67·9]; p<0·0001). There were no device-related adverse patient outcomes and short-term safety outcomes favoured automated control.

Interpretation: Automated titration of oxygen partnered with a low-cost CPAP device improved time spent in the safe SpO2 range compared with manual control. There is high potential for this technology to mitigate the risk of oxygen-mediated complications in preterm infants in low-resource settings.

Funding: National Health and Medical Research Council Australia and University of Tasmania.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Lancet Global Health
Lancet Global Health PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
44.10
自引率
1.20%
发文量
763
审稿时长
10 weeks
期刊介绍: The Lancet Global Health is an online publication that releases monthly open access (subscription-free) issues.Each issue includes original research, commentary, and correspondence.In addition to this, the publication also provides regular blog posts. The main focus of The Lancet Global Health is on disadvantaged populations, which can include both entire economic regions and marginalized groups within prosperous nations.The publication prefers to cover topics related to reproductive, maternal, neonatal, child, and adolescent health; infectious diseases (including neglected tropical diseases); non-communicable diseases; mental health; the global health workforce; health systems; surgery; and health policy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信