A Prospective Crossover Study Comparing Six Current Generation Supraglottic Airway Device's Ability to Seal During CPR in Human Cadavers

IF 1.2 4区 医学 Q3 EMERGENCY MEDICINE
Joe Holley MD , Robert Dunne MD , Heather Robinson MD , Richard Williams RRT , Andisheh Motealleh PhD
{"title":"A Prospective Crossover Study Comparing Six Current Generation Supraglottic Airway Device's Ability to Seal During CPR in Human Cadavers","authors":"Joe Holley MD ,&nbsp;Robert Dunne MD ,&nbsp;Heather Robinson MD ,&nbsp;Richard Williams RRT ,&nbsp;Andisheh Motealleh PhD","doi":"10.1016/j.jemermed.2024.08.012","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Supraglottic airway (SGA) devices are frequently used during cardiopulmonary respiration (CPR), but little is known about their ability to consistently seal the airway during CPR.</div></div><div><h3>Objectives</h3><div>The objective of this prospective crossover human cadaver study was a comparison of intrathoracic pressures (ITPs) generated during automated CPR (aCPR) with an Impedance Threshold Device (ZOLL Medical Corporation, Chelmsford, MA) with six currently available SGAs to a standard endotracheal tube (ETT). The hypothesis was that current SGAs would vary in their ability to develop ITPs compared with the ETT.</div></div><div><h3>Methods</h3><div>Airway pressures and negative ITP were measured in six recently deceased human cadavers of varying body habitus. After placement of an ETT and six different SGAs, we assessed airway and ITPs during aCPR and manual positive pressure ventilation using bag-valve mask. The ETT served as the control for airway seal and was placed first followed by each SGA. Primary outcome compared airway and ITP among all groups.</div></div><div><h3>Results</h3><div>SGAs varied in their ability to create negative airway pressure and negative ITP.</div></div><div><h3>Conclusion</h3><div>In this human cadaver model, the ability to generate negative ITP varied with different SGAs during aCPR with an Impedance Threshold Device.</div></div>","PeriodicalId":16085,"journal":{"name":"Journal of Emergency Medicine","volume":"69 ","pages":"Pages 25-31"},"PeriodicalIF":1.2000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Emergency Medicine","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S073646792400266X","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Supraglottic airway (SGA) devices are frequently used during cardiopulmonary respiration (CPR), but little is known about their ability to consistently seal the airway during CPR.

Objectives

The objective of this prospective crossover human cadaver study was a comparison of intrathoracic pressures (ITPs) generated during automated CPR (aCPR) with an Impedance Threshold Device (ZOLL Medical Corporation, Chelmsford, MA) with six currently available SGAs to a standard endotracheal tube (ETT). The hypothesis was that current SGAs would vary in their ability to develop ITPs compared with the ETT.

Methods

Airway pressures and negative ITP were measured in six recently deceased human cadavers of varying body habitus. After placement of an ETT and six different SGAs, we assessed airway and ITPs during aCPR and manual positive pressure ventilation using bag-valve mask. The ETT served as the control for airway seal and was placed first followed by each SGA. Primary outcome compared airway and ITP among all groups.

Results

SGAs varied in their ability to create negative airway pressure and negative ITP.

Conclusion

In this human cadaver model, the ability to generate negative ITP varied with different SGAs during aCPR with an Impedance Threshold Device.
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Emergency Medicine
Journal of Emergency Medicine 医学-急救医学
CiteScore
2.40
自引率
6.70%
发文量
339
审稿时长
2-4 weeks
期刊介绍: The Journal of Emergency Medicine is an international, peer-reviewed publication featuring original contributions of interest to both the academic and practicing emergency physician. JEM, published monthly, contains research papers and clinical studies as well as articles focusing on the training of emergency physicians and on the practice of emergency medicine. The Journal features the following sections: • Original Contributions • Clinical Communications: Pediatric, Adult, OB/GYN • Selected Topics: Toxicology, Prehospital Care, The Difficult Airway, Aeromedical Emergencies, Disaster Medicine, Cardiology Commentary, Emergency Radiology, Critical Care, Sports Medicine, Wound Care • Techniques and Procedures • Technical Tips • Clinical Laboratory in Emergency Medicine • Pharmacology in Emergency Medicine • Case Presentations of the Harvard Emergency Medicine Residency • Visual Diagnosis in Emergency Medicine • Medical Classics • Emergency Forum • Editorial(s) • Letters to the Editor • Education • Administration of Emergency Medicine • International Emergency Medicine • Computers in Emergency Medicine • Violence: Recognition, Management, and Prevention • Ethics • Humanities and Medicine • American Academy of Emergency Medicine • AAEM Medical Student Forum • Book and Other Media Reviews • Calendar of Events • Abstracts • Trauma Reports • Ultrasound in Emergency Medicine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信