Yuyang Zhang, Gongning Luo, Wei Wang, Shaodong Cao, Suyu Dong, Daren Yu, Xiaoyun Wang, Kuanquan Wang
{"title":"A continuous-action deep reinforcement learning-based agent for coronary artery centerline extraction in coronary CT angiography images.","authors":"Yuyang Zhang, Gongning Luo, Wei Wang, Shaodong Cao, Suyu Dong, Daren Yu, Xiaoyun Wang, Kuanquan Wang","doi":"10.1007/s11517-025-03284-3","DOIUrl":null,"url":null,"abstract":"<p><p>The lumen centerline of the coronary artery allows vessel reconstruction used to detect stenoses and plaques. Discrete-action-based centerline extraction methods suffer from artifacts and plaques. This study aimed to develop a continuous-action-based method which performs more effectively in cases involving artifacts or plaques. A continuous-action deep reinforcement learning-based model was trained to predict the artery's direction and radius value. The model is based on an Actor-Critic architecture. The Actor learns a deterministic policy to output the actions made by an agent. These actions indicate the centerline's direction and radius value consecutively. The Critic learns a value function to evaluate the quality of the agent's actions. A novel DDR reward was introduced to measure the agent's action (both centerline extraction and radius estimate) at each step. The method achieved an average OV of 95.7%, OF of 93.6%, OT of 97.3%, and AI of 0.22 mm in 80 test data. In 53 cases with artifacts or plaques, it achieved an average OV of 95.0%, OF of 91.5%, OT of 96.7%, and AI of 0.23 mm. The 95% limits of agreement between the reference and estimated radius values were <math><mo>-</mo></math> 0.46 mm and 0.43 mm in the 80 test data. Experiments demonstrate that the Actor-Critic architecture can achieve efficient centerline extraction and radius estimate. Compared with discrete-action-based methods, our method performs more effectively in cases involving artifacts or plaques. The extracted centerlines and radius values allow accurate coronary artery reconstruction that facilitates the detection of stenoses and plaques.</p>","PeriodicalId":49840,"journal":{"name":"Medical & Biological Engineering & Computing","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2025-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical & Biological Engineering & Computing","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11517-025-03284-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0
Abstract
The lumen centerline of the coronary artery allows vessel reconstruction used to detect stenoses and plaques. Discrete-action-based centerline extraction methods suffer from artifacts and plaques. This study aimed to develop a continuous-action-based method which performs more effectively in cases involving artifacts or plaques. A continuous-action deep reinforcement learning-based model was trained to predict the artery's direction and radius value. The model is based on an Actor-Critic architecture. The Actor learns a deterministic policy to output the actions made by an agent. These actions indicate the centerline's direction and radius value consecutively. The Critic learns a value function to evaluate the quality of the agent's actions. A novel DDR reward was introduced to measure the agent's action (both centerline extraction and radius estimate) at each step. The method achieved an average OV of 95.7%, OF of 93.6%, OT of 97.3%, and AI of 0.22 mm in 80 test data. In 53 cases with artifacts or plaques, it achieved an average OV of 95.0%, OF of 91.5%, OT of 96.7%, and AI of 0.23 mm. The 95% limits of agreement between the reference and estimated radius values were 0.46 mm and 0.43 mm in the 80 test data. Experiments demonstrate that the Actor-Critic architecture can achieve efficient centerline extraction and radius estimate. Compared with discrete-action-based methods, our method performs more effectively in cases involving artifacts or plaques. The extracted centerlines and radius values allow accurate coronary artery reconstruction that facilitates the detection of stenoses and plaques.
期刊介绍:
Founded in 1963, Medical & Biological Engineering & Computing (MBEC) continues to serve the biomedical engineering community, covering the entire spectrum of biomedical and clinical engineering. The journal presents exciting and vital experimental and theoretical developments in biomedical science and technology, and reports on advances in computer-based methodologies in these multidisciplinary subjects. The journal also incorporates new and evolving technologies including cellular engineering and molecular imaging.
MBEC publishes original research articles as well as reviews and technical notes. Its Rapid Communications category focuses on material of immediate value to the readership, while the Controversies section provides a forum to exchange views on selected issues, stimulating a vigorous and informed debate in this exciting and high profile field.
MBEC is an official journal of the International Federation of Medical and Biological Engineering (IFMBE).