{"title":"Scanning K-edge subtraction (SKES) imaging with laser-compton x-ray sources","authors":"Trevor Reutershan,&nbsp;Christine V. Nguyen,&nbsp;Haytham H. Effarah,&nbsp;Eric C. Nelson,&nbsp;Kyle D. Chesnut,&nbsp;Christopher P. J. Barty","doi":"10.1002/mp.17638","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons. Laser-Compton x-ray sources (LCSs) are a compact alternative to synchrotron radiation with a quasimonoenergetic x-ray spectrum. One limitation in the clinical application of KES imaging with LCSs has been the extensive time required to tune the x-ray spectrum to two different energies.</p>\n </section>\n \n <section>\n \n <h3> Purpose</h3>\n \n <p>We introduce an imaging technique called scanning K-edge subtraction (SKES) that leverages the angle-correlated laser-Compton x-ray spectrum in the setting of mammography. The feasibility and utility of this technique will be evaluated through a series of simulation studies. The goal of SKES imaging is to enable rapid K-edge subtraction imaging using a laser-Compton x-ray source. The technique does not rely on the time-consuming process of tuning laser-Compton interaction parameters.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Laser-Compton interaction physics are modeled using conditions based on an X-band linear electron accelerator architecture currently under development using a combination of 3D particle tracking software and Mathematica. The resulting angle-correlated laser-Compton x-ray beam is propagated through digitally compressed breast phantoms containing iodine contrast-enhanced inserts and then to a digital flat-panel detector using a Matlab Monte Carlo propagation software. This scanning acquisition technique is compared to the direct energy tuning method (DET), as well as to a clinically available dual-energy contrast-enhanced mammography (CEM) system.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>KES imaging in a scanning configuration using an LCS was able to generate a KES image of comparable quality to the direct energy tuning method. SKES was able to detect tumors with iodine contrast concentrations lower than what is clinically available today including lesions that are typically obscured by dense fibroglandular tissue. After normalizing to mean glandular dose, SKES is able to generate a KES image with equal contrast to CEM using only 3% of the dose.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>By leveraging the unique quasimonochromatic and angle-correlated x-ray spectrum offered by LCSs, a contrast-enhanced subtraction image can be obtained with significantly more contrast and less dose compared to conventional systems, and improve tumor detection in patients with dense breast tissue. The scanning configuration of this technique could accelerate the clinical translation of this technology.</p>\n </section>\n </div>","PeriodicalId":18384,"journal":{"name":"Medical physics","volume":"52 4","pages":"2475-2492"},"PeriodicalIF":3.2000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/mp.17638","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical physics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/mp.17638","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background

K-edge subtraction (KES) imaging is a dual-energy imaging technique that enhances contrast by subtracting images taken with x-rays that are above and below the K-edge energy of a specified contrast agent. The resulting reconstruction spatially identifies where the contrast agent accumulates, even when obscured by complex and heterogeneous distributions of human tissue. This method is most successful when x-ray sources are quasimonoenergetic and tunable, conditions that have traditionally only been met at synchrotrons. Laser-Compton x-ray sources (LCSs) are a compact alternative to synchrotron radiation with a quasimonoenergetic x-ray spectrum. One limitation in the clinical application of KES imaging with LCSs has been the extensive time required to tune the x-ray spectrum to two different energies.

Purpose

We introduce an imaging technique called scanning K-edge subtraction (SKES) that leverages the angle-correlated laser-Compton x-ray spectrum in the setting of mammography. The feasibility and utility of this technique will be evaluated through a series of simulation studies. The goal of SKES imaging is to enable rapid K-edge subtraction imaging using a laser-Compton x-ray source. The technique does not rely on the time-consuming process of tuning laser-Compton interaction parameters.

Methods

Laser-Compton interaction physics are modeled using conditions based on an X-band linear electron accelerator architecture currently under development using a combination of 3D particle tracking software and Mathematica. The resulting angle-correlated laser-Compton x-ray beam is propagated through digitally compressed breast phantoms containing iodine contrast-enhanced inserts and then to a digital flat-panel detector using a Matlab Monte Carlo propagation software. This scanning acquisition technique is compared to the direct energy tuning method (DET), as well as to a clinically available dual-energy contrast-enhanced mammography (CEM) system.

Results

KES imaging in a scanning configuration using an LCS was able to generate a KES image of comparable quality to the direct energy tuning method. SKES was able to detect tumors with iodine contrast concentrations lower than what is clinically available today including lesions that are typically obscured by dense fibroglandular tissue. After normalizing to mean glandular dose, SKES is able to generate a KES image with equal contrast to CEM using only 3% of the dose.

Conclusions

By leveraging the unique quasimonochromatic and angle-correlated x-ray spectrum offered by LCSs, a contrast-enhanced subtraction image can be obtained with significantly more contrast and less dose compared to conventional systems, and improve tumor detection in patients with dense breast tissue. The scanning configuration of this technique could accelerate the clinical translation of this technology.

Abstract Image

求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical physics
Medical physics 医学-核医学
CiteScore
6.80
自引率
15.80%
发文量
660
审稿时长
1.7 months
期刊介绍: Medical Physics publishes original, high impact physics, imaging science, and engineering research that advances patient diagnosis and therapy through contributions in 1) Basic science developments with high potential for clinical translation 2) Clinical applications of cutting edge engineering and physics innovations 3) Broadly applicable and innovative clinical physics developments Medical Physics is a journal of global scope and reach. By publishing in Medical Physics your research will reach an international, multidisciplinary audience including practicing medical physicists as well as physics- and engineering based translational scientists. We work closely with authors of promising articles to improve their quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信