Implant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Gianmario Schierano, Domenico Baldi, Bruno Peirone, Mitzy Mauthe von Degerfeld, Fabio Modica, Vincenzo Notaro, Cecilia Boretto, Giuliana Muzio, Riccardo Autelli
{"title":"Implant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs.","authors":"Gianmario Schierano, Domenico Baldi, Bruno Peirone, Mitzy Mauthe von Degerfeld, Fabio Modica, Vincenzo Notaro, Cecilia Boretto, Giuliana Muzio, Riccardo Autelli","doi":"10.1111/jopr.14025","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.</p><p><strong>Materials and methods: </strong>Two implant sites were prepared in the tibia of four minipigs. At the time of implant placement (T0), bone cortex thickness and Implant Stability Quotient (ISQ) were assessed. A bone specimen was collected from the tibia and used as the baseline for biomolecular analyses. X-ray was taken after implant insertion. After 14 days (T14), a computed tomography (CT) scan of the tibias was conducted, and ISQ values were reassessed. Histological and biomolecular analyses were performed on bone sections containing the implant.</p><p><strong>Results: </strong>ISQ significantly increased from T0 to T14, in the absence of any correlation between the cortical thickness and ISQ. In two animals, CT showed a slight trabecular bone thickening adjacent to the implants and disorganized radiodense spots; in the other two, no trabecular osseodensification was evident. Newly formed bone was about 48% of the tissue around implants. At T14, an increase in osteogenic factors and a decrease in inflammatory molecules were observed.</p><p><strong>Conclusion: </strong>This study enhances understanding of the biological and clinical responses at bone implant sites following piezoelectric surgery. It highlights the relationship between the rise in certain osteogenic factors and new bone formation, as well as a potential association with increased ISQ.</p>","PeriodicalId":49152,"journal":{"name":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","volume":" ","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2025-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthodontics-Implant Esthetic and Reconstructive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jopr.14025","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.

Materials and methods: Two implant sites were prepared in the tibia of four minipigs. At the time of implant placement (T0), bone cortex thickness and Implant Stability Quotient (ISQ) were assessed. A bone specimen was collected from the tibia and used as the baseline for biomolecular analyses. X-ray was taken after implant insertion. After 14 days (T14), a computed tomography (CT) scan of the tibias was conducted, and ISQ values were reassessed. Histological and biomolecular analyses were performed on bone sections containing the implant.

Results: ISQ significantly increased from T0 to T14, in the absence of any correlation between the cortical thickness and ISQ. In two animals, CT showed a slight trabecular bone thickening adjacent to the implants and disorganized radiodense spots; in the other two, no trabecular osseodensification was evident. Newly formed bone was about 48% of the tissue around implants. At T14, an increase in osteogenic factors and a decrease in inflammatory molecules were observed.

Conclusion: This study enhances understanding of the biological and clinical responses at bone implant sites following piezoelectric surgery. It highlights the relationship between the rise in certain osteogenic factors and new bone formation, as well as a potential association with increased ISQ.

用压电技术制备的牙种植体稳定商数和成骨过程:在小型猪身上的研究。
目的:很少有研究探讨使用压电装置制备的牙种植体部位的骨反应,表明在增强二次稳定性和成骨方面有中等效果。本研究旨在扩大我们对压电手术制备的骨整合初始阶段的生物学、临床和放射学参数变化的理解。材料与方法:在4只小型猪的胫骨上制备2个种植体。种植体放置时(T0),评估骨皮质厚度和种植体稳定性商(ISQ)。从胫骨采集骨标本,作为生物分子分析的基线。植入后拍x线片。14天后(T14),对胫骨进行计算机断层扫描(CT),并重新评估ISQ值。对含种植体的骨切片进行组织学和生物分子分析。结果:从T0到T14, ISQ显著增加,皮质厚度与ISQ无相关性。2只动物CT显示植入物附近有轻微的骨小梁增厚和杂乱的放射性致密点;另外2例未见骨小梁骨化。新形成的骨约占植入物周围组织的48%。在T14时,观察到成骨因子增加,炎症分子减少。结论:本研究提高了对压电手术后骨植入部位的生物学和临床反应的理解。它强调了某些成骨因子的增加与新骨形成之间的关系,以及与ISQ增加的潜在关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.90
自引率
15.00%
发文量
171
审稿时长
6-12 weeks
期刊介绍: The Journal of Prosthodontics promotes the advanced study and practice of prosthodontics, implant, esthetic, and reconstructive dentistry. It is the official journal of the American College of Prosthodontists, the American Dental Association-recognized voice of the Specialty of Prosthodontics. The journal publishes evidence-based original scientific articles presenting information that is relevant and useful to prosthodontists. Additionally, it publishes reports of innovative techniques, new instructional methodologies, and instructive clinical reports with an interdisciplinary flair. The journal is particularly focused on promoting the study and use of cutting-edge technology and positioning prosthodontists as the early-adopters of new technology in the dental community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信