Shahid Mansoor, Azhar Hussain Malik, Khizar Hayat Satti, Misbah Ijaz, Muhammad Tariq Siddique
{"title":"Experimental and GEANT4 simulated FEPE of NaI(Tl) detector for linear sources.","authors":"Shahid Mansoor, Azhar Hussain Malik, Khizar Hayat Satti, Misbah Ijaz, Muhammad Tariq Siddique","doi":"10.1088/2057-1976/adaec8","DOIUrl":null,"url":null,"abstract":"<p><p>The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using<sup>99m</sup>Tc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.7 cm. The FEPE is measured for the fabricated linear source using 2″×2″ NaI(Tl) cylindrical detector at various source-detector distances. The experimental setup is simulated in GEANT4 and the computed FEPE values are compared with experimental values. The absolute error of 5% is observed between computed and measured FEPE values. Utilizing the advantages of MC simulations, the impact of numerous source parameters such as source length, diameter, source-detector distance, glass tube thickness and lead shield effects on FEPE are investigated to optimize the fabrication process of linear sources. A case study for current investigation has been analyzed by considering absolute FEPE of the NaI(Tl) system for a syringe filled with radioactive solution. This study provides an insight for the fabrication of standard linear sources by analyzing different source parameters and hence, may serve as a guideline to prepare standard linear sources for the calibration of radiation detectors.</p>","PeriodicalId":8896,"journal":{"name":"Biomedical Physics & Engineering Express","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Physics & Engineering Express","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2057-1976/adaec8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The current study investigated the geometry, design and solid angle impacts on full energy peak efficiency (FEPE) of NaI(Tl) detectors for a line source. A line source is fabricated using99mTc solution filled in a borosilicate glass tube of inner diameter 3 mm, tube wall thickness 2.5 mm and length 12.7 cm. The FEPE is measured for the fabricated linear source using 2″×2″ NaI(Tl) cylindrical detector at various source-detector distances. The experimental setup is simulated in GEANT4 and the computed FEPE values are compared with experimental values. The absolute error of 5% is observed between computed and measured FEPE values. Utilizing the advantages of MC simulations, the impact of numerous source parameters such as source length, diameter, source-detector distance, glass tube thickness and lead shield effects on FEPE are investigated to optimize the fabrication process of linear sources. A case study for current investigation has been analyzed by considering absolute FEPE of the NaI(Tl) system for a syringe filled with radioactive solution. This study provides an insight for the fabrication of standard linear sources by analyzing different source parameters and hence, may serve as a guideline to prepare standard linear sources for the calibration of radiation detectors.
期刊介绍:
BPEX is an inclusive, international, multidisciplinary journal devoted to publishing new research on any application of physics and/or engineering in medicine and/or biology. Characterized by a broad geographical coverage and a fast-track peer-review process, relevant topics include all aspects of biophysics, medical physics and biomedical engineering. Papers that are almost entirely clinical or biological in their focus are not suitable. The journal has an emphasis on publishing interdisciplinary work and bringing research fields together, encompassing experimental, theoretical and computational work.