Finite Element Analysis of Proximal Femoral Bionic Nail (PFBN), Proximal Femoral Nail Antirotation and InterTan for Treatment of Reverse Obliquity Intertrochanteric Fractures.

IF 1.8 2区 医学 Q2 ORTHOPEDICS
Orthopaedic Surgery Pub Date : 2025-03-01 Epub Date: 2025-01-25 DOI:10.1111/os.14345
Chen Xiong, Lijia Zhang, Yanhua Wang, Xiaomeng Zhang, Xiaofeng Chen, Kai Yu, Yichong Zhang, Huijuan Fu, Zhentao Ding, Dianying Zhang
{"title":"Finite Element Analysis of Proximal Femoral Bionic Nail (PFBN), Proximal Femoral Nail Antirotation and InterTan for Treatment of Reverse Obliquity Intertrochanteric Fractures.","authors":"Chen Xiong, Lijia Zhang, Yanhua Wang, Xiaomeng Zhang, Xiaofeng Chen, Kai Yu, Yichong Zhang, Huijuan Fu, Zhentao Ding, Dianying Zhang","doi":"10.1111/os.14345","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.1).</p><p><strong>Methods: </strong>The three-dimensional models of PFBN, PFNA, InterTan, and the A3.1 type intertrochanteric fracture model were established by using modeling software such as Mimics and Unigraphics. Different force loads were implemented using ANSYS software to compare finite element biomechanical parameters, such as maximum stress in the implant and maximum stress and displacement at the proximal femur.</p><p><strong>Results: </strong>In this finite element study, we found that the distribution trend of maximum femoral stress and displacement in the femoral models of the three internal fixation groups was similar, but the maximum stress and maximum displacement were the lowest in the PFBN group, and the maximum stress of the internal fixation implant in the PFBN group was lower than that in the PFNA group and the InterTan group. The maximum stress and displacement of the femur in the PFNA group were 403.71 MPa and 14.274 mm, respectively, the maximum stress and displacement in the InterTan group were 362.72 MPa and 10.678 mm, and the maximum stress and displacement in the PFBN group were 186.23 MPa and 9.7068 mm. In the internal fixation implant model, the maximum stress of the PFNA group was 1445 MPa, the maximum stress of the InterTan group was 919.62 MPa, and the maximum stress of the PFBN group was the lowest, at 911.77 MPa.</p><p><strong>Conclusion: </strong>Compared to PFNA and InterTan, PFBN designed by the \"lever - reconstruction - balance\" hypothesis can provide better biomechanical stability. It is a feasible choice for the future treatment of reverse intertrochanteric fracture, and additional clinical studies are required to substantiate its efficacy.</p>","PeriodicalId":19566,"journal":{"name":"Orthopaedic Surgery","volume":" ","pages":"888-899"},"PeriodicalIF":1.8000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11872354/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/os.14345","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.1).

Methods: The three-dimensional models of PFBN, PFNA, InterTan, and the A3.1 type intertrochanteric fracture model were established by using modeling software such as Mimics and Unigraphics. Different force loads were implemented using ANSYS software to compare finite element biomechanical parameters, such as maximum stress in the implant and maximum stress and displacement at the proximal femur.

Results: In this finite element study, we found that the distribution trend of maximum femoral stress and displacement in the femoral models of the three internal fixation groups was similar, but the maximum stress and maximum displacement were the lowest in the PFBN group, and the maximum stress of the internal fixation implant in the PFBN group was lower than that in the PFNA group and the InterTan group. The maximum stress and displacement of the femur in the PFNA group were 403.71 MPa and 14.274 mm, respectively, the maximum stress and displacement in the InterTan group were 362.72 MPa and 10.678 mm, and the maximum stress and displacement in the PFBN group were 186.23 MPa and 9.7068 mm. In the internal fixation implant model, the maximum stress of the PFNA group was 1445 MPa, the maximum stress of the InterTan group was 919.62 MPa, and the maximum stress of the PFBN group was the lowest, at 911.77 MPa.

Conclusion: Compared to PFNA and InterTan, PFBN designed by the "lever - reconstruction - balance" hypothesis can provide better biomechanical stability. It is a feasible choice for the future treatment of reverse intertrochanteric fracture, and additional clinical studies are required to substantiate its efficacy.

求助全文
约1分钟内获得全文 求助全文
来源期刊
Orthopaedic Surgery
Orthopaedic Surgery ORTHOPEDICS-
CiteScore
3.40
自引率
14.30%
发文量
374
审稿时长
20 weeks
期刊介绍: Orthopaedic Surgery (OS) is the official journal of the Chinese Orthopaedic Association, focusing on all aspects of orthopaedic technique and surgery. The journal publishes peer-reviewed articles in the following categories: Original Articles, Clinical Articles, Review Articles, Guidelines, Editorials, Commentaries, Surgical Techniques, Case Reports and Meeting Reports.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信